11.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA
SIEPC71061753A GA500 Technical Manual
441
Name
Unit
Default
-
Drive Model
-
4007
4009
4012
4018
C6-01
Normal /
Heavy Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive Model
(KVA)
Selection
Hex.
95
96
97
99
E2-11
(E4-11, E5-
02)
Motor Rated
Power
kW
2.2
3.0
3.0
3.7
4.0
5.5
5.5
7.5
b8-04
Energy Saving
Coefficient
Value
-
313.6
265.7
265.7
245.8
245.8
189.5
189.5
145.38
C6-02
Carrier
Frequency
Selection
-
3
7
3
7
3
7
3
7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A
4.2
5.7
5.7
7
7
9.8
9.8
13.3
E2-02
(E4-02)
Motor Rated
Slip
Hz
3
2.7
2.7
2.7
2.7
1.5
1.5
1.3
E2-03
(E4-03)
Motor No-
Load Current
A
1.5
1.9
1.9
2.3
2.3
2.6
2.6
4
E2-05
(E4-05)
Motor Line-
to-Line
Resistance
Ω
6.495
4.36
4.36
3.333
3.333
1.595
1.595
1.152
E2-06
(E4-06)
Motor
Leakage
Inductance
%
18.7
19
19
19.3
19.3
18.2
18.2
15.5
E2-10
(E4-10)
Motor Iron
Loss
W
77
105
105
130
130
193
193
263
E5-01
PM Motor
Code
Selection
-
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
L2-02
Power Loss
Ride Through
Time
s
0.5
0.5
0.5
0.5
0.5
0.5
0.8
0.8
L2-03
Minimum
Baseblock
Time
s
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.8
L2-04
Powerloss V/f
Recovery
Ramp Time
s
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
L2-05
Undervoltage
Detection Lvl
(Uv1)
-
380
380
380
380
380
380
380
380
L3-02
Stall Prevent
Level during
Accel
%
150
120
150
120
150
120
150
120
L3-06
Stall Prevent
Level during
Run
%
150
120
150
120
150
120
150
120
L3-24
Motor Accel
Time @ Rated
Torque
s
0.145
0.145
0.145
0.154
0.154
0.168
0.168
0.175
L8-02
Overheat
Alarm Level
°C
90
90
115
115
110
110
120
120
L8-09
Output
Ground Fault
Detection
-
0
0
0
0
0
0
0
0
n1-03
Hunting
Prevention
Time Constant
ms
10
10
10
10
10
10
10
10
n3-02
HSB Current
Limit Level
%
150
120
150
120
150
120
150
120
n5-02
Motor Inertia
Acceleration
Time
s
0.145
0.145
0.145
0.154
0.154
0.168
0.168
0.175
*1
Parameters within parentheses are for motor 2.
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...