No.
Name
Range
Unit
Control Method (A1-02 Setting)
V/f
(0)
OLV
(2)
E1-07
Mid Point A Frequency
0.0 - 400.0
0.1 Hz
3.0
E1-08
Mid Point A Voltage
0.0 - 255.0
0.1 V
11.0
E1-09
Minimum Output
Frequency
0.0 - 400.0
0.1 Hz
0.5
E1-10
Minimum Output Voltage
0.0 - 255.0
0.1 V
2.0
F1-09
Overspeed Detection
Delay Time
0.0 - 2.0
0.1 s
-
-
L1-01
Motor Overload (oL1)
Protection
0 - 4
1
1
1
L2-31
KEB Start Voltage Offset
Level
0 - 100
1 V
0
0
L3-05
Stall Prevention during
RUN
0 - 3
1
1
1
L3-20
DC Bus Voltage
Adjustment Gain
0.00 - 5.00
0.01
1.00
0.30
L3-21
OVSuppression Accel/
Decel P Gain
0.10 - 10.00
0.01
1.00
1.00
L3-36
Current Suppression
Gain@Accel
0.0 - 100.0
0.1
10.0
20.0
L4-01
Speed Agree Detection
Level
0.0 - 400.0
0.1
0.0 Hz
0.0 Hz
L4-02
Speed Agree Detection
Width
0.0 - 20.0
0.1
2.0 Hz
2.0 Hz
L4-03
Speed Agree Detection
Level(+/-)
-400.0 - +400.0
0.1
0.0 Hz
0.0 Hz
L4-04
Speed Agree Detection
Width(+/-)
0.0 - 20.0
0.1
2.0 Hz
2.0 Hz
L8-40
Carrier Freq Reduction
Off-Delay
0.00 - 2.00
0.01 s
0.50
0.50
L8-90
STPo Detection Level
(Low Speed)
0 - 5000
1
-
-
n5-04
Speed Response Frequency
0.00 - 500.00
0.00 Hz
-
-
n8-35
Initial Pole Detection
Method
0 - 2
1
-
-
n8-51
Pull-in Current @
Acceleration
0 - 200%
1
0
0
o1-03
Frequency Display Unit
Selection
0 - 3
1
0
0
o1-04
V/f Pattern Display Unit
0 - 1
1
-
-
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
*2
The default setting changes when the setting of
C6-01 [Normal / Heavy Duty Selection]
changes.
*3
The setting range changes when the setting of
E5-01 [PM Motor Code Selection]
changes when
A1-02 = 5 [OLV/PM]
.
*4
The default setting changes when the drive model and
E1-03 [V/f Pattern Selection]
change.
*5
This is the value for 200 V class drives. Double the value for 400 V class drives.
*6
When
A1-02 = 5 [OLV/PM]
, the maximum value of the setting range is 100.0.
*7
When
A1-02 = 5 [OLV/PM]
, the setting range is -100.0 to +100.0.
Table 11.2 A1-02 = 5, 6, 8 [OLV/PM, AOLV/PM, EZOLV]
No.
Name
Range
Unit
Control Method (A1-02 Setting)
OLV/PM
(5)
AOLV/PM
(6)
EZOLV
(8)
b2-01
DC Injection/Zero
SpeedThreshold
0.0 - 10.0
0.1
0.5 Hz
1.0%
0.5Hz
b2-04
DC Inject Braking Time at
Stop
0.00 - 10.00
0.01 s
0.00
0.00
0.00
b3-01
Speed Search at Start
Selection
0 - 1
1
0
0
0
b3-02
SpeedSearch Deactivation
Current
0 - 200
1%
-
-
-
b3-08
Speed Estimation ACR P
Gain
0.00 - 6.00
0.01
0.30
0.30
0.30
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...