YASKAWA
SIEPC71061753A GA500 Technical Manual
171
Table 5.7 Recommended Fuse: Three-Phase 400 V Class
Drive Model
Fuse
Manufacturer: Bussmann
Model
4001
FWH-40B
4002
FWH-40B
4004
FWH-50B
4005
FWH-70B
4007
FWH-70B
4009
FWH-90B
4012
FWH-90B
Drive Model
Fuse
Manufacturer: Bussmann
Model
4018
FWH-80B
4023
FWH-100B
4031
FWH-125B
4038
FWH-175B
4044
FWH-200B
4060
FWH-200B
◆
EMC Directive
Use drives with built-in EMC filters or install external EMC filters to the drive input side to comply with the
EMC Directive.
Drives with built-in EMC filters (models 2xxxE, BxxxE, 4xxxE) were tested in accordance with European
standard EN 61800-3:2004/A1:2012, and comply with the EMC Directive.
■
Install a Drive to Conform to the EMC Directive
Install drive models 2xxxE, BxxxE, and 4xxxE with this procedure to comply with the EMC Directive when the
drive is a single unit or installed in a larger device.
1.
Install the drive on a grounded metal plate.
2.
Wire the drive and motor.
3.
Ground the wire shielding on the drive side and motor side.
A - Drive
B - Wiring length
C - Motor
D - Metal conduit
E - Grounding wire
Figure 5.4 Wiring the Drive and Motor
*1
The maximum wiring length between the drive and motor is:
• 2xxxE, 4xxxE: 20 m (65.6 ft)
• BxxxE: 10 m (32.8 ft)
Note:
• Use a braided shield cable for the drive and motor wiring or put the wires through a metal conduit.
• Keep the cable between the drive and motor and the grounding wire as short as possible.
4.
Use a cable clamp to ground the motor cable to the metal plate.
Note:
Make sure that the protective ground wire complies with technical specifications or local safety standards.
Содержание CIPR-GA50C series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 157: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 157...
Страница 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 159: ...Standards Compliance 5 5 2 European Standards YASKAWA SIEPC71061753A GA500 Technical Manual 159...
Страница 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...
Страница 454: ...11 22 Parameters Changed by PM Motor Code Selection 454 YASKAWA SIEPC71061753A GA500 Technical Manual...