2 Mechanical & Electrical Installation
YASKAWA ELECTRIC
SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
55
Mod
el
Dimensions mm (in.)
W
H
D1
D2
W1
W2
W3
W4
W5
W6
H1
H2
H3
H4
H5
A
B
d1
4216
312
(12.2
8)
700
(27.5
6)
260
(10.2
4)
160
(6.30)
218
(8.58)
263
(10.3
5)
39
(1.54)
8
(0.31
5)
-
-
675
(26.5
6)
33
(1.29
9)
12
(0.47
2)
32
(1.26)
13
(0.51
2)
296
(11.6
5)
610
(24.0
2)
M10
4260
312
(12.2
8)
700
(27.5
6)
260
(10.2
4)
160
(6.30)
218
(8.58)
263
(10.3
5)
39
(1.54)
8
(0.31
5)
-
-
675
(26.5
6)
33
(1.29
9)
12
(0.47
2)
32
(1.26)
13
(0.51
2)
296
(11.6
5)
610
(24.0
2)
M10
4304
440
(17.3
2)
800
(31.5
0)
254
(10.0
0)
218
(8.58)
370
(14.5
7)
310
(12.2
0)
23
(0.91)
12
(0.47
2)
-
-
773
(30.4
3)
31.5
(1.24
0)
14
(0.55
1)
31.5
(1.24)
13
(0.51
2)
416
(16.3
8)
710
(27.9
5)
M12
4371
440
(17.3
2)
800
(31.5
0)
254
(10.0
0)
218
(8.58)
370
(14.5
7)
310
(12.2
0)
23
(0.91)
12
(0.47
2)
-
-
773
(30.4
3)
31.5
(1.24
0)
14
(0.55
1)
31.5
(1.24)
13
(0.51
2)
416
(16.3
8)
710
(27.9
5)
M12
4414
510
(20.0
8)
1136
(44.7
2)
260
(10.2
4)
220
(8.66)
450
(17.7
2)
404
(15.9
1)
18
(0.71)
12
(0.47
2)
179
(7.05)
225
(8.86)
1110
(43.7
0)
34
(1.33
9)
15
(0.59
1)
34
(1.34)
15
(0.59
1)
486
(19.1
3)
1042
(41.0
2)
M12
4453
510
(20.0
8)
1136
(44.7
2)
260
(10.2
4)
220
(8.66)
450
(17.7
2)
404
(15.9
1)
18
(0.71)
12
(0.47
2)
179
(7.05)
225
(8.86)
1110
(43.7
0)
34
(1.33
9)
15
(0.59
1)
34
(1.34)
15
(0.59
1)
486
(19.1
3)
1042
(41.0
2)
M12
4605
510
(20.0
8)
1136
(44.7
2)
260
(10.2
4)
220
(8.66)
450
(17.7
2)
404
(15.9
1)
18
(0.71)
12
(0.47
2)
179
(7.05)
225
(8.86)
1110
(43.7
0)
34
(1.33
9)
15
(0.59
1)
34
(1.34)
15
(0.59
1)
486
(19.1
3)
1042
(41.0
2)
M12
*1
The attachment for external heatsink installation is necessary.
◆
Electrical Installation
DANGER
Electrical Shock Hazard. Do not examine, connect, or disconnect wiring on an energized drive. Before
servicing, disconnect all power to the equipment and wait for the time specified on the warning label at a minimum. The internal
capacitor stays charged after the drive is de-energized. The charge indicator LED extinguishes when the DC bus voltage
decreases below 50 Vdc. When all indicators are OFF, remove the covers before measuring for dangerous voltages to make
sure that the drive is safe. Failure to obey will cause death or serious injury.
DANGER
Electrical Shock Hazard. Make sure that all electrical connections are correct and install all drive covers
before energizing the drive. Use terminals for their intended function only. Incorrect wiring or ground connections, and incorrect
repair of protective covers can cause death or serious injury.
WARNING
Electrical Shock Hazard. Correctly ground the drive before turning on the EMC filter switch. Failure to obey
can cause death or serious injury.
WARNING
Electrical Shock Hazard. Used the terminals for the drive only for their intended purpose. Refer to the
technical manual for more information about the I/O terminals. Wiring and grounding incorrectly or modifying the cover may
damage the equipment or cause injury.
■
Standard Connection Diagram
Wire the drive as specified by Figure 2.68.
WARNING
Sudden Movement Hazard. Correctly wire the start/stop and safety circuits and make sure that the drive
operates correctly when the drive is energized. Failure to obey can cause death or serious injury from moving equipment.
WARNING
Sudden Movement Hazard. Execute the Application Preset function after checking I/O signal and the external
sequence for the drive. Executing the Application Preset function (A1-06
≠
0) changes the I/O terminal function for the drive and
may trigger unexpected operation in equipment. Failure to comply may cause death or serious injury.
WARNING
Fire Hazard. Install sufficient branch circuit short circuit protection as specified by applicable codes and this
manual. The drive is suited for circuits that supply not more than 100,000 RMS symmetrical amperes, 240 Vac maximum (200 V
Class), 480 Vac maximum (400 V Class). Failure to obey can cause death or serious injury.
NOTICE
When the input voltage is 440 V or higher or if the wiring distance is longer than 100 m (328 ft.) be sure to use
a drive duty motor or carefully monitor the motor insulation voltage. Failure to obey can cause damage to the motor insulation.
NOTICE
Do not connect the AC control circuit ground to the drive enclosure. Failure to obey can cause incorrect
control circuit operation.