32
YASKAWA
SIEP C730600 83E CC-Link Technical Manual
Signal
Name
Description
Comments (Default)
RY17
Term MA/MB-MC Function
Fault Contact Output
-
RY18, 19
Reserved
-
-
RY1A
Fault Reset
Resets a D1000 fault.
-
RY1B - 1F
Reserved
-
-
*1
Terminals are different for different drive models. Refer to
Terminals that Change depending on the Model of the Drive on page 35
for more information.
Note:
Although RYF is triggered by the rising edge of the signal, they are otherwise enabled depending on the value that is input.
D1000 → PLC
Table 8.4 Remote I/O List (D1000 → PLC)
Signal
Name
Description
Comments (Default)
RX0
During Run/During Stop
ON: During Run
OFF: Stop
-
RX1
During Regeneration
ON: During Regeneration
-
RX2
Terminal M1-M2 Function
Multi-function output: H2-01 [Terminal M1-M2 Function Selection]
H2-01 = 25
RX3
During Run (Converter Ready)
-
-
RX4
Reserved
-
-
RX5
Uv [Undervoltage]
-
-
RX6
Terminal P1-PC Function
Multi-function output: H2-02 [Terminal P1-PC Function Selection]
H2-02 = 26 [During MC ON]
RX7
Terminal P2-PC Function
Multi-function output: H2-03 [Terminal P2-PC Function Selection]
H2-03 = 6 [Converter Ready]
RX8
Momentary Power Loss Ride-
Thru/Power Loss Recovery
-
-
RX9
ComCtrlstatus/NetCtrlstatus
-
-
RXA
CC-Link Option Fault
Communication error between D1000 and CC-Link device
-
RXB
During Active Current Limit
-
-
RXC
Obtain Monitor Data
ON: Monitor data has been updated.
-
RXD
Alarm
-
-
RXE
Fault
-
-
RXF
Command Code Execute
Complete
ON: Displayed after the specified command code has been executed.
RXF signal switches OFF when the RYF command is no longer present.
-
RX10
During Reset Signal Input
-
-
RX11
oPE Error
-
-
RX12
AUv [Power Supply
Undervoltage]
-
-
RX13 - 19
Reserved
-
-
RX1A
Error
ON: Fault occurred on the D1000 side.
-
RX1B
Remote Station Ready
ON: D1000 is ready to operate.
-
RX1C - 1F
Reserved
-
-
*1
Terminals are different for different drive models. Refer to
Terminals that Change depending on the Model of the Drive on page 35
for more information.
◆
Remote Register
Note:
Remote register data varies between drives and D1000 that support this option.