EMC
Standard
Comment
Emitted interference
EN 61000-6-4
Class A (Industrial area)
Noise immunity
zone B
EN 61000-6-2
Industrial area
EN 61000-4-2
ESD
8kV at air discharge (degree of severity 3),
4kV at contact discharge (degree of severity 2)
EN 61000-4-3
HF field immunity (casing)
80MHz … 1000MHz, 10V/m, 80% AM (1kHz)
1.4GHz ... 2.0GHz, 3V/m, 80% AM (1kHz)
2GHz ... 2.7GHz, 1V/m, 80% AM (1kHz)
EN 61000-4-6
HF conducted
150kHz … 80MHz, 10V, 80% AM (1kHz)
EN 61000-4-4
Burst, degree of severity 3
EN 61000-4-5
Surge, degree of severity 3
1
1) Due to the high-energetic single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is
necessary.
2.6 Use in difficult operating conditions
Without additional protective measures, the products must not be used in
locations with difficult operating conditions; e.g. due to:
–
dust generation
–
chemically active substances (corrosive vapors or gases)
–
strong electric or magnetic fields
2.7 Technical data
Order no.
67S-RRJ0-EB
Type
Panel PC PPC021 CE
Display
Display size (diagonal)
21.5 "
Display size (width)
478 mm
Display size (height)
269 mm
Resolution
1080 x 1920 / 1920 x 1080
Aspect ratio
16:9
Type of display
TFT color (16.7M colors)
MTBF Backlights (25°C)
50000 h
System properties
HMI
Hardware description
Technical data
HB160 | PPC | 67S-RRJ0 | en | 23-10
19
Содержание 67S-PNJ0-EB
Страница 1: ...PPC 67S RRJ0 Manual HB160 PPC 67S RRJ0 en 23 10 HMI Panel PC PPC021 EC...
Страница 14: ...HMI Hardware description Structure Interfaces HB160 PPC 67S RRJ0 en 23 10 14...
Страница 72: ...Appendix HMI Appendix HB160 PPC 67S RRJ0 en 23 10 72...
Страница 73: ...Content A History of changes 74 HMI Appendix HB160 PPC 67S RRJ0 en 23 10 73...