background image

The next start-up takes place without requesting the log-in data.

The 

‘Enhanced Write Filter’

 is a tool which can be used to disable permanent writing

accesses to the internal drive "C:". It can be written to the drive but the data is not stored

permanently.

1.

Open the configuration window of the Enhanced Write Filter by clicking   icon in

the system tray.

2.

In the next window click on [Configure].

3.

In the following window select 

enable

 under 

‘Pending command’

 to enable the

Enhanced Write Filter.

4.

Confirm with [Apply] and [OK].

5.

To disable the Enhanced Write Filters select 

Commit and disable live

 under

‘Pending command’

.

Please note that a status change of the Enhanced Write Filter will only

take effect after a restart of the system.

Enhanced Write Filter

VIPA HMI

Deployment Panel PC

Operating system Windows Embedded Standard 7 > Structure

HB160 | PPC | 67P-RSL0 | en | 20-20

 

36

Содержание 67P-RSL0

Страница 1: ...PPC 67P RSL0 Manual HB160 PPC 67P RSL0 en 20 20 VIPA HMI Panel PC PPC015 ES...

Страница 2: ...67P RSL0_000_PPC015ES 2 EN 2020 YASKAWA Europe GmbH Ohmstra e 4 91074 Herzogenaurach Tel 49 9132 744 0 Fax 49 9132 744 186 Email info yaskawa eu com Internet www yaskawa eu com...

Страница 3: ...g 26 3 3 1 Firmware update 26 3 3 2 Startup Manager 27 3 4 Connection to a PLC system 30 3 5 Operating system Windows Embedded Standard 7 31 3 5 1 General 31 3 5 2 Structure 32 4 BIOS setup 37 4 1 Ove...

Страница 4: ...Descriptions may be included for units which are not present at the customer site The exact scope of delivery is described in the respective purchase contract Hereby YASKAWA Europe GmbH declares that...

Страница 5: ...PC 67P RSL0 It contains a description of the structure project engineering and deployment Product Order number as of state HW FW BS PPC015 ES 67P RSL0 01 1 0 0 Windows Embedded Standard 7 The manual...

Страница 6: ...rsonnel in the n project design department n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the components described in...

Страница 7: ...les that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices a...

Страница 8: ...CAP multitouch n Display resolution 1366 x 768 n Processor Baytrail Intel Celeron J1900 Quad core 2GHz n Work memory 2x 204Pin DDR3 SO DIMM Socket 4GB DDR3 n User memory 16GB SSD SLC n CFast slot n 2...

Страница 9: ...3 0 7 2x USB A interface USB 2 0 8 RJ45 jack for Ethernet communication LAN 2 9 RJ45 jack for Ethernet communication LAN 1 10 2 pin connector for remote Power switch 11 3 5mm Audio Line out 12 Power...

Страница 10: ...RJ45 jack for Ethernet communication LAN 2 9 RJ45 jack for Ethernet communication LAN 1 10 2 pin connector for remote Power switch 11 3 5mm Audio Line out Please make sure that the Panel PC always has...

Страница 11: ...n the Panel PC switches to the sleep mode by briefly pushing the power switch By pushing the power switch again the sleep mode is switched off 2 3 2 Interfaces The Panel PC has got an integrated power...

Страница 12: ...it s RS422 interface n Logical conditions as voltage difference between 2 twisted lines n Serial bus connection full duplex four wire operation n Line length 250m at 115 2kbit s 1200m at 19 2kbit s n...

Страница 13: ...VIPA HMI Hardware description Structure Interfaces HB160 PPC 67P RSL0 en 20 20 13...

Страница 14: ...cks provide the interface to the twisted pair cable required for Ethernet LEDs Activity yellow Link green Link orange Description blinks 1000Mbit s link blinks 100Mbit s link blinks 10Mbit s link or n...

Страница 15: ...the Panel PC there is a card slot for a memory card At this slot you can plug storage modules of the type CFast 2 0 600 MB s 6GBit s SATA protocol not hot swap compatible Pin Assignment Pin Assignment...

Страница 16: ...x H x D 396 x 291 x 57 60mm Installation depth 57 60mm The degrees of protection are only guaranteed when the following is observed The material thickness of the installation cut out is 3 12mm The de...

Страница 17: ...ion voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14 2...

Страница 18: ...pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data 2 6 1 67P RSL0 JB Order n...

Страница 19: ...connector Sub D 9 pin male Serial COM2 RS232 RS422 RS485 COM2 connector Sub D 9 pin male Number of USB A interfaces 3 USB A connector USB A host Number of USB B interfaces USB B connector Number of et...

Страница 20: ...ide IP 20 Protection class NEMA front side Protection class NEMA back side Dimensions Front panel 417 8 mm x 312 8 mm x 6 2 mm Rear panel 396 mm x 291 mm x 57 6 mm Installation cut out Width 401 mm He...

Страница 21: ...rk memory 4 GB User memory 16 GB Available memory user data 4 GB SD MMC Slot CF Card Slot Typ II CFast Slot Time Real time clock buffered Clock buffered period min 4 y Type of buffering lithium batter...

Страница 22: ...ange DC 20 4 28 8 V Reverse polarity protection Current consumption no load operation 1 2 A Current consumption rated value 1 3 A Inrush current 1 3 A I t 0 35 A s Power loss 32 W Status information a...

Страница 23: ...m Net weight 6 2 kg Weight including accessories Gross weight Environmental conditions Operating temperature 10 C to 60 C Storage temperature 20 C to 75 C Certifications UL certification yes KC certif...

Страница 24: ...g tableau and control cabinet fronts the Panel PC requires the following front panel cutting Panel PC W x H in mm 67P RSL0 401 x 296mm The material thickness of the installation cut out is 3 12mm For...

Страница 25: ...ulling the plate 2 With the label facing up insert the CFast card until it is completely seated in the slot and reinstall the cover plate After installation the CFast card is automatically recognized...

Страница 26: ...t not be let within the same cable shaft as high voltage cables 3 3 1 Firmware update To execute the firmware update an external keyboard and an USB stick memory size 4GB is necessary The new image fi...

Страница 27: ...pting the start countdown By default no password is defined In Settings the system settings can be set exactly like via Windows Start Control Panel n Under Backlight control you can adjust the brightn...

Страница 28: ...y Time you can adjust a delay time 0 by using the buttons and 5 seconds are default n Via Rotation the orientation of the panel can be changed n Via Program Start with you can add programmes which hav...

Страница 29: ...ight the local settings and the LAN settings will be saved by Backup in Flashdisk Backup The name of the backup file is backup bkv Which settings will be saved and the storage location are defined in...

Страница 30: ...e version of the HMI SCADA project engineering platforms your project is run able n By using the according communication driver the Panel PC supports connecting options to the PLC via Ethernet n Durin...

Страница 31: ...re differentiated n Double click A double click has to be executed like mouse operation by touching the area at the screen twice A double click on an object opens res executes this n Drag By tapping o...

Страница 32: ...e following structure 1 Start button This button offers you access to all components of your Panel PC such as appli cations system settings file browser etc 2 Windows Explorer The Windows Explorer is...

Страница 33: ...ware keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown At the moment the following keyboards...

Страница 34: ...idge via Bridge Connections in the context menu A further Ethernet adapter called Network Bridge will be displayed Here you can make all settings n System properties Via Start Settings System and Secu...

Страница 35: ...1 Type cmd under Start Run 2 In the next window type control userpasswords2 3 In the opening dialog window uncheck the box User must enter a user name and password to use this computer and confirm wi...

Страница 36: ...in the system tray 2 In the next window click on Configure 3 In the following window select enable under Pending command to enable the Enhanced Write Filter 4 Confirm with Apply and OK 5 To disable th...

Страница 37: ...Making changes to the power management configuration n Changing the password or making other changes to the security setup Normally CMOS setup is needed when the system hardware is not consistent wit...

Страница 38: ...ves and exits the setup program Enter Enters the highlighted submenu When 4 appears on the left of a particular field it indicates that a submenu which contains addi tional options are available for t...

Страница 39: ...mat is hour minute second n hour displays hours from 00 to 23 n minute displays minutes from 00 to 59 n second displays seconds from 00 to 59 4 3 Advanced This menu allows you to configure the system...

Страница 40: ...This section is used to configure Advanced Configuration and Power Interface ACPI Settings Submenu ACPI Settings VIPA HMI BIOS setup Advanced HB160 PPC 67P RSL0 en 20 20 40...

Страница 41: ...hen the suspend button is pressed Suspend Disabled Sleep state disabled S3 Suspend to RAM Standby mode enabled Windows saves the system state in RAM This section is used to configure serial ports Enab...

Страница 42: ...splays the Super I O Chip used on the board This section is used to configure serial port 1 Super IO Chip Submenu Serial Port 1 Configuration VIPA HMI BIOS setup Advanced HB160 PPC 67P RSL0 en 20 20 4...

Страница 43: ...esistor Disabled Terminal resistor not activated Enabled default Terminal resistor activated This section is used to configure serial port 2 Enables or disables the serial port Disabled Serial port is...

Страница 44: ...minal resistor not activated Enabled default Terminal resistor activated This section Pc Health Status is used to configure the hardware temperature and vol tages This section is used to configure the...

Страница 45: ...ctions are supported Enabled Limit the return value to 3 or less than 3 XD can prevent certain classes of malicious buffer overflow attacks Enabled Permit the switching on of the execute disable funct...

Страница 46: ...This section is used to configure the Processor Power Management PPM configuration Submenu PPM Configu ration VIPA HMI BIOS setup Advanced HB160 PPC 67P RSL0 en 20 20 46...

Страница 47: ...o use AHCI Advanced Host Con troller Interface AHCI allows the storage driver to enable the advanced serial ATA features which will increase storage performance Enables or disables SATA port 0 Enables...

Страница 48: ...ications Enabled Default Enables USB 3 0 controller support Disabled Disables USB 3 0 controller support Enabled Enables XHCI USB 3 0 or EHCI USB 2 0 support Disabled Disables XHCI USB 3 0 or EHCI USB...

Страница 49: ...is option only when changing the panel otherwise the display may not work The options are Tact Switch Manual and Light Sensor The default setting is Manual and the Backlight option below will be confi...

Страница 50: ...where you left off before power failure occurs Power Off The system s power is off You must press the power button to Power On the system Power On default The system will automatically Power On This s...

Страница 51: ...isabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally enabled Enables or disables internal HDMI Codec for Azalia Audio Controller Azalia HDMI Codec VIPA HMI BIOS setup...

Страница 52: ...HCI con troller must always be enabled Enables or disables PCH USB rate matching hubs mode Enables or disables PCH EHCI debug capability Submenu USB Configura tion USB 2 0 EHCI Support USB RMH Mode US...

Страница 53: ...Enables or disables the PCI Express ports 0 3 on the chipset Submenu PCI Express Configuration PCI Express Port 0 PCI Express Port 3 VIPA HMI BIOS setup Chipset HB160 PPC 67P RSL0 en 20 20 53...

Страница 54: ...decrease the time needed to boot the system Controls the execution of UEFI and legacy PXE OpROM Enables or disables the boot option for legacy network devices connected to LAN1 or LAN2 Disabled defaul...

Страница 55: ...en entering setup If only the User s password is set then this is a power on password and must be entered to boot or enter setup In Setup the user will have administrator rights If ONLY the Administra...

Страница 56: ...t 3 characters and should be maximal 20 characters long Select this to reconfigure the user s password Your password must contain at least 3 characters and should be maximal 20 characters long Adminis...

Страница 57: ...irm again before exiting The BIOS setup exits and a restart follows To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes To save...

Страница 58: ...erent ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free...

Страница 59: ...lkie n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following...

Страница 60: ...special EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrica...

Страница 61: ...tage even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts ha...

Страница 62: ...groups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed...

Страница 63: ...e of the equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is c...

Страница 64: ...he cover Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to...

Страница 65: ...Z diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutra...

Страница 66: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunc...

Страница 67: ...Appendix VIPA HMI Appendix HB160 PPC 67P RSL0 en 20 20 67...

Страница 68: ...Content A History of changes 69 VIPA HMI Appendix HB160 PPC 67P RSL0 en 20 20 68...

Страница 69: ...A History of changes Rev Changes 18 25 The manual was created 20 20 CI adjustment was done VIPA HMI History of changes HB160 PPC 67P RSL0 en 20 20 69...

Отзывы: