the dialog windows
for the display properties opens. Here you may change the settings
for the monitor options. For example you may adjust the brightness
and contrast via the register
Settings.
Calibrate touch screen
If your touch screen does not always react on a double click or recog-
nizes the position of an entry not precisely, you may call the dialog
Stylus
via
‘Start
è
Settings
è
Control Panel ’
.In the register
Double-
Tap
you may use the grid pattern to preset a double click velocity and
test this on the symbol below. OK takes over the set value. The cali-
bration of the touch screens happens via the register
Calibration
by
following the instructions.
Set Ethernet parameters
The dialog field for pre-setting an Ethernet address is to be found at
‘Start
è
Settings
è
Network and Dial-up Connections’
. The default
setting is address assignment via DHCP.
Please consider with the manual assignment of IP
addresses that these are not identical for both interfaces. If
you accidentally have assigned to the same IP address to
both interfaces, then only one interface icon is shown at
‘Network and Dial- up Connections’ . By switching to
DHCP, you receive 2 Interface icons again and can con-
figure them individually.
System properties (System)
Here you receive information about the version of the current Win-
dows
Ò
operating system, the memory load and sharing (alterations
here are not taken over into the registry) and about the copyright. The
register Device Name allows you to change the
device name
that is
e.g. shown during Ethernet communication.
Set the break time of the back-lighting
Via
‘Start
è
Settings
è
Control Panel
è
Power Properties’
you may
set the break time of the back-lighting. For this choose AC Power at
"Power Scheme" and then set the appropriate time at "Switch state to
System Idle".
To configure the MPI/DP interface on the Touch Panel start via
‘Start
è
Settings
è
Control Panel’
or via "Settings" in the VIPA Startup-
Manager the tool "MPI/DP slave Configuration".
Default: MPI - Address 1
The following settings are only required if not communicate via
Movicon.
Configuration MPI/DP
slave
VIPA HMI Touch Panel
Deployment Touch Panel
Operating system Windows
Ò
Embedded CE 6.0 Core> Structure
HB160 | TP-ECO | 62P-NHC0 | GB | 13-45