H1 Multi-Function Digital Input Selections
H1-
oo
Setting
Function
Description
Control
Mode
Pg.
V/
f
O
L
V
P
M
44
Offset Frequency 1 Addition
Closed: Adds d7-01 to the frequency reference.
O
O
O
45
Offset Frequency 2 Addition
Closed: Adds d7-02 to the frequency reference.
O
O
O
46
Offset Frequency 3 Addition
Closed: Adds d7-03 to the frequency reference.
O
O
O
47
<1>
Node Setup
Closed: Node setup for SI-S3/V enabled.
O
O
O
60
DC Injection Braking Command
Closed: Triggers DC Injection Braking (b2-02)
O
O
-
61
External Search Command 1
Closed: Activates Current Detection Speed Search from the max. output
frequency (E1-04) if b3-01 = 0. Activates Speed Estimation Type Speed
search if b3-01 = 0.
O
O
O
62
External Search Command 2
Closed: Activates Current Detection Speed Search from the frequency
reference b3-01 = 0. Activates Speed Estimation Type Speed search if b3-01
= 0.
O
O
O
65
KEB Ride-Thru 1 (N.C.)
Open: KEB Ride-Thru 1 enabled
Closed: Normal operation
O
O
O
66
KEB Ride-Thru 1 (N.O.)
Open: Normal operation
Closed: KEB Ride-Thru 1 enabled
O
O
O
67
Communications Test Mode
Tests the MEMOBUS/Modbus RS-485/422 interface.
O
O
O
68
High-Slip Braking
Closed: High-Slip braking is executed. Drive stops.
O
-
-
6A
Drive Enable
Open: Drive disabled.
If this input is opened during run, then the drive will stop as specified by
parameter b1-03.
Closed: Ready for operation.
O
O
O
75
Up 2 Command
Open: Maintains the current frequency reference.
Closed: Increases or decreases the frequency reference.
UP 2 and Down 2 commands must be set in combination with each other.
The frequency reference source must be assigned to the operator (b1-01 =
“0”).
O
O
O
76
Down 2 Command
O
O
O
7A
KEB Ride-Thru 2 (N.C.)
Open: KEB Ride-Thru 2 enabled
Closed: Normal operation
O
O
O
7B
KEB Ride-Thru 2 (N.O.)
Open: Normal operation
Closed: KEB Ride-Thru 2 enabled
O
O
O
7C
Short-Circuit Braking (N.O.)
Open: Normal operation
Closed: Short-Circuit Braking
-
-
O
7D
Short-Circuit Braking (N.C.)
Open: Short-Circuit Braking
Closed: Normal operation
-
-
O
7E
Forward/Reverse Detection
Direction of rotation detection (for V/f with Simple PG Feedback)
O
-
-
90 to 96
DWEZ Digital Inputs 1 to 7
Reserved for DWEZ input functions
O
O
O
9F
DriveWorksEZ enable
Open: DWEZ enabled
Closed: DWEZ disabled
O
O
O
<1> Available in drive software versions PRG: 1016 and later.
No.
Name
Description
Range
Def.
Control
Mode
Addr.
Hex
Pg.
V/
f
O
L
V
P
M
H2: Multi-Function Digital Outputs
Use H2 parameters to assign functions to the multi-function digital outputs.
H2-01
Terminal MA, MB and MC Function
Selection (relay)
Refer to H2 Multi-Function Digital Output
Settings on page
values.
0 to 192
<1>
E
A A A
40B
H2-02
Terminal P1 Function Selection (open-
collector)
0
A A A
40C
H2-03
Terminal P2 Function Selection (open-
collector)
2
A A A
40D
B.2 Parameter Table
378
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual