will change which of the main menus are displayed. Menus A6 through A9 will be
accessible when periodic flush timing is selected, while menus A10 and A11 are used for
scheduled flush timing.
Master Valve Offset
Default Value:
Disabled
Navigate to menu B5 to view the Master Offset menu. This menu allows the user to select
the delay between when the master valve is turned on and when the first station is turned
on. Selecting the “disabled” option means that the master valve is not used.
Solenoid Valve Type Configuration
Default Value:
12VDC, Continuous
Navigate to menu B6 to view the “Valve Setup” menu. This menu allows the user to
configure the type and power supply of the solenoid valves used in the installation. Press
select and rotate the dial to choose the type (continuous or latching), then press select and
rotate the dial to choose the power source (12VDC or 24VAC). 24VAC solenoids cannot be
used when the controller is powered with 12VDC. Press select once more to save your
choices.
System Time
Default Value:
N/A
Navigate to menu B12 to view the Set Time menu. Press select to begin the process of
setting the system time. All flush timing settings are based on the system time which can be
seen at the top of every menu.
Station Duration
Default Value:
3 minutes
Navigate to menu A3 and press select to set the duration of time that each station will be
active for.
Station Delay
Default Value:
20 seconds
Navigate to menu A4 and press select to set the amount of time between each station
turning off and the next station turning on in the Delay menu.