background image

 

[email protected]

HEIGHT:

8’2” or 2.49m

12 x 12 Pergola room

Installation and Operating Instructions – YM11635X

Yardistry – North America

Toll Free Customer Support: 1.888.509.4382

[email protected]

www.yardistrystructures.com

Yardistry / Selwood Products – Europe

Customer Support: +44 1284 852569

[email protected]

www.selwoodproducts.com

Revised 12/22/2014

10’ (3.05 m)

12’ (3.66 m)

3.05 m (10’)

3.66 m (12’)

Retractable Sunshade Sold Separately 

Содержание YM11635X

Страница 1: ...istry North America Toll Free Customer Support 1 888 509 4382 info yardistrystructures com www yardistrystructures com Yardistry Selwood Products Europe Customer Support 44 1284 852569 parts selwoodproducts com www selwoodproducts com Revised 12 22 2014 10 3 05 m 12 3 66 m 3 05 m 10 3 66 m 12 Retractable Sunshade Sold Separately ...

Страница 2: ...oo close to a Yardistry structure Consult user s manual of the grill fire pit or chimnea for safe distances from combustible materials Wear gloves to avoid injury from possible sharp edges of individual elements before assembly During installation follow all safety warnings provided with your tools and use OHSA approved safety glasses Some structures may require two or more people to install safel...

Страница 3: ... not limited to wind storms hail floods excessive water exposure Minor twisting warping checking or any other natural occurring properties of wood that do not affect performance or integrity Yardistry products have been designed for safety and quality Any modifications made to the original product could damage the structural integrity of the product leading to failure and possible injury Yardistry...

Страница 4: ...th of use and then annually Do not over tighten as to cause crushing and splintering of wood Check for sharp edges or protruding screw threads add washers if required WOOD PARTS Unprotected they will appear weathered over time Periodic application of an exterior water repellent or stain water based will help improve appearance and life Check all wood members for deterioration structural damage and...

Страница 5: ... mounting to concrete footers see below for the correct locations and placement Please double check for possibility of any underground utilities such as gas telephone cable or sprinkler lines Following are some examples of how to mount the structure to wood or concrete surfaces Refer to your local building and city codes ordinances neighbourhood covenants or height restrictions regarding this type...

Страница 6: ...ete Patio min 10 2 x 10 2 with 12 clearance on all sides Wood Deck min 10 2 x 10 2 with 12 clearance on all sides 10 x 1 1 4 Pan Screws Included 10 x 1 1 4 Pan Screws Included Anchoring Hardware not included Anchoring Hardware not included Room L Mount 10 x 1 1 4 Pan Screw Post ...

Страница 7: ...Beam End 34 1 4 192 hidden Beam 20 3 4 067 End Plinth Assembly 032 2 x 3 Trellis Clip Arch Gusset Right 193 Arch Beam Offset 080 Arch Beam Front 195 Arch Gusset Left 194 Corner Post 190 Corner Panel Assembly 024 025 Assembled Trellis End 33 1 2 062 L Mount Right Beam 81 1 2 301 L Mount Left Short Plinth A Assembly 035 Arch Beam Center 079 ...

Страница 8: ...1 x 139 7 x 527 1mm 36 x 127 x 453 2mm 36 x 127 x 453 2mm Part Identification Dimensions are approximate and are shown to assist in the identification of parts for assembly Actual dimensions may be smaller or larger 32pc 185 Horizontal Insert 2 x 2 x 16 1 8 Box 2 Y50119 185 64pc X Insert 2 x 2 x 22 5 8 Box 3 Y50119 183 9pc 062 Trellis End 33 1 2 2 x 3 x 33 1 2 Box 1 Y50119 062 8pc 189 Cross Brace ...

Страница 9: ... 3048 0mm Y50119 195 Corner Post 3 x 3 x 91 Box 2 4pc 190 69 9 x 69 9 x 2311 4mm Y50119 190 34 9 x 152 4 x 141 3mm 8pc 032 End Plinth Assembly Box 2 Y70119 032 34 9 x 152 4 x 598 5mm 8pc 033 Long Plinth Assembly Box 2 Y70119 033 34 9 x 152 4 x 492 1mm 4pc 035 Short Plinth A Assemlby Box 2 Y70119 035 34 9 x 152 4 x 492 1mm 4pc 034 Short Plinth B Assembly Box 2 Y70119 034 Arch Beam Center 2 x 6 x120...

Страница 10: ... Drill Bit Y00400 002 1pc 2 x 2 Robertson Driver 9200014 9 pc 2 x 3 Trellis Clip Y00419 003 32pc X Insert Pin Y0814 001 16pc 5 16 Flat Washer Y05420 301 8pc Wafer Bolt 1 4 x 3 3 4 Y07420 233 96pc Trim Screw 6 x 30mm Y06420 910 8pc L Mount Left Y00419 004 9pc 1 4 Lock Nut Y08420 203 8pc Wafer Bolt 1 4 x 4 1 4 Y07420 241 9pc Wafer Bolt 1 4 x 2 Y07420 220 50pc Pan Screw 10 x 1 1 4 Y06420 911 98pc Woo...

Страница 11: ...ties or sprinkler line locations prior to excavating any holes D Before you discard your cartons fill out the form below The carton I D stamp is located on the end of each carton Please retain this information for future reference You will need this information if you contact the Consumer Relations Department Each step indicates which bolts and or screws you will need for assembly as well as any f...

Страница 12: ...8 1 x 574 7 mm 2 x 2 x 22 5 8 Hardware Wood Parts Fig 2 1 32 x X Insert Pin A Place one X Insert Pin into one X Insert then attach a second X Insert to form a complete Insert Make sure the pieces are tight to each other B Repeat Step A to make 32 complete Inserts X Insert Pin X Insert ...

Страница 13: ...n in fig 3 1 C Set one Horizontal Insert between the posts and tight to Bottom Brace Insert Attach with two 8 x 3 Wood Screw as shown in figure 3 1 32 x 8 x 3 Wood Screw 024 Engineered Panel Post 8 x 024 Engineered Panel Post 36 x 69 9 x 2311 4 mm 2 x 4 x 91 8 x 191 Bottom Brace Insert 38 1 x 69 9 x 409 6 mm 2 x 4 x 16 1 8 8 x 185 Horizontal Insert 38 1 x 38 1 x 409 6 mm 2 x 2 x 16 1 8 8 x 025 Eng...

Страница 14: ...a 189 Cross Brace Insert Attach all three Horizontal Inserts with two 8 x 3 Wood Screws per insert and attach Cross Brace Insert with four 8 x 3 Wood Screws fig 3 3 80 x 8 x 3 Wood Screw 024 Engineered Panel Post 32 x Completed Inserts from Step 2 8 x 189 Cross Brace Insert 38 1 x 76 2 x 409 6 mm 2 x 4 x 91 24 x 185 Horizontal Insert 38 1 x 38 1 x 409 6 mm 2 x 2 x 91 Fig 3 3 185 Horizontal Insert ...

Страница 15: ...one post per assembly A On Engineered Panel Corner Post per assembly pre drill two holes from the inside at the places shown in fig 4 1 and 4 2 Pre drill in the centre of the panel and on a slight angle Fig 4 2 Fig 4 1 Pre drill on a slight angle 024 Engineered Panel Post 025 Engineered Panel Corner Post ...

Страница 16: ...91 Fig 4 3 B Through the pre drilled holes attach two Panel Posts assemblies to one 190 Corner Post with one 10 x 4 Wood Screw per Panel Post Assembly at bottom and six 8 x 2 1 2 Wood Screws along post as shown in fig 4 3 Start at the bottom and work up Complete this step for all four Corner Posts 190 Corner Post 8 x 2 1 2 Wood Screws 8 x 2 1 2 Wood Screws 10 x 4 Wood Screws 8 x 2 1 2 Wood Screws ...

Страница 17: ...th two 10 x 1 1 4 Pan Screw per L Mount as shown in fig 5 1 5 2 and 5 3 Step 5 Attach L Mount Brackets Fig 5 1 Fig 5 2 Hardware 16 x Room L Mount Right and Left 32 x 10 x 1 1 4 Pan Screw 10 x 1 1 4 Pan Screw Flush to bottom of posts x 2 per L Mount L Mount Left L Mount Right L Mount Left L Mount Right Note orientation of tabs Fig 5 3 L Mount Right L Mount Left Note Flush to the inside edge ...

Страница 18: ...ner Post Assembly Part 1 A Place one 034 Short Plinth B Assembly with one 035 Short Plinth A Assembly tight to each other and attach using two 6 x 30 mm Trim Screw at the opposite corners per Plinth Fig 6 1 and 6 2 Note Plinths will be attached to four corners Fig 6 1 Fig 6 2 16 x 6 x 30 mm Trim Screw 4 x 035 Short Plinth A Assembly 34 9 x 152 4 x 492 1 mm 4 x 034 Short Plinth B Assembly 34 9 x 15...

Страница 19: ...tach Plinths to Corner Post Assembly Part 2 B On the outside of the corner post assembly place two 033 Long Plinth Assembly tight against eachother using 2 6 x 30 mm Trim Screws per Plinth Be sure they are flush and tight Fig 6 3 and 6 4 Fig 6 3 Fig 6 4 16 x 6 x 30 mm Trim Screw 8 x 033 Long Plinth Assembly 34 9 x 152 4 x 598 5 mm ...

Страница 20: ... End Plinth Assembly Step 6 Attach Plinths to Corner Post Assembly Part 3 C Place one 032 End Plinth Assembly onto each Corner Post Assembly Line them up with previously placed Plinths Make sure they are flush and tight to each other and then fasten with two 6 x 30 mm Trim Screw per end Fig 6 5 and 6 6 Fig 6 5 Fig 6 6 16 x 6 x 30 mm Trim Screw 8 x 032 End Plinth Assembly 34 9 x 152 4 x 141 3 mm ...

Страница 21: ... lined up flush and level before installing remaining screws D After the End Plinths have been placed go back and install the two remaining 6 x 30 mm Trim Screws per end to the assembled Plinth of the Pergola Room Fig 6 7 and 6 8 E Attach 2 6 x 30 mm Trim Screws to each end side as shown in fig 6 7 and 6 8 Fig 6 7 Fig 6 8 48 x 6 x 30 mm Trim Screw ...

Страница 22: ...quare as shown in fig 7 1 The distance from the outside of one Corner Post to the outside of a second Corner Post should be 120 See fig 7 1 and 7 2 for accurate placement and additional measurements 1 6 9 1 1 1 6 120 X4 78 5 X4 78 5 120 120 78 5 169 11 16 move to final position Fig 7 2 78 1 2 78 1 2 78 1 2 C Depending on what you are placing the Pergola Room on will determine how you anchor it to ...

Страница 23: ...ace attach one 069 Beam End 10 1 2 to 192 Beam End 34 1 4 with three 10 x 4 Wood Screws as shown in fig 8 1 B Repeat Step A three more times so you have four assemblies Note that two of the Beam Ends should be on the same side as the cut out and two should be on the opposite side fig 8 1 and 8 2 069 Beam End 10 1 2 192 Beam End 34 1 4 Fig 8 2 10 x 4 Wood Screws 10 x 4 Wood Screws 069 Beam End 10 1...

Страница 24: ...lt 5 16 flat washer 1 4 connector nut 4 x 1 4 x 3 3 4 Wafer Bolt 5 16 flat washer 1 4 connector nut 301 Beam 81 1 2 Beam End Assembly Fig 9 1 8 x 3 Wood Screw Cut out Flat Washer 1 4 x 4 1 4 Wafer Bolt Flat Washer Beam End Assembly Beam End Assembly 301 Beam 81 1 2 Panel Post B Fit one 301 Beam 81 1 2 in between two Corner Post Assemblies and attach to Beam End assemblies and Panel Post as shown i...

Страница 25: ...and attach with three 10 x 4 Wood Screws per side fig 10 3 Step 10 Attach Arch Beam Fronts 2 x 195 Arch Beam Front 38 1 x 241 3 x 3048 mm 2 x 6 x 120 1 x 079 Arch Beam Centre 38 1 x 241 3 x 3048 mm 2 x 6 x 120 Hardware Wood Parts Fig 10 2 12 x 8 x 3 Wood Screw 6 x 10 x 4 Wood Screw 4 x 1 4 x 4 1 4 Wafer Bolt 5 16 flat washer 1 4 connector nut 4 x 1 4 x 3 3 4 Wafer Bolt 5 16 flat washer 1 4 connect...

Страница 26: ...x 2 1 2 Wood Screw and six 10 x 4 Wood Screws per Beam 20 3 4 as shown in fig 11 1 and 11 2 Step 11 Attach Arch Beam Offsets 2 x 080 Arch Beam Offset 38 1 x 241 3 x 3048 mm 2 x 6 x 120 4 x 067 Beam 20 3 4 38 1 x 139 7 x 527 1 mm 2 x 6 x 20 3 4 Hardware Wood Parts Fig 11 2 36 x 10 x 4 Wood Screw 8 x 8 x 2 1 2 Wood Screw 080 Arch Beam Offset Fig 11 1 8 x 2 1 2 Wood Screw Engineered Panel Post 080 Ar...

Страница 27: ...k nut fig 12 2 C Repeat Steps A and B until there are 9 Trellis End Assemblies Step 12 Assemble Trellis Ends 9 x 062 Trellis End 33 1 2 38 1 x 63 5 x 850 9 mm 2 x 3 x 33 1 2 9 x 300 Trellis End 110 1 2 38 1 x 63 5 x 850 9 mm 2 x 3 x 110 1 2 Hardware Wood Parts Fig 12 2 9 x Trellis Clip 9 x 1 4 x 2 Wafer Bolt 1 4 lock nut 062 Trellis End 33 1 2 Fig 12 1 1 4 x 2 Wafer Bolt 1 4 Lock Nut 300 Trellis E...

Страница 28: ...ed in fig 13 1 and 13 2 C Attach Trellis Clip to Arch Beam Offset with two 10 x 1 1 4 Pan Screws as shown in fig 13 1 and 13 3 Step 13 Attach Trellis End Assemblies Part 1 Hardware 4 x 10 x 4 Wood Screw 2 x 10 x 1 1 4 Pan Screw 10 x 4 Wood Screw 10 x 1 1 4 Pan Screw 59 1 4 Trellis End Assembly Arch Beam Offset Arch Beam Front Arch Beam Offset Arch Beam Front Trellis Clip Fig 13 1 Fig 13 2 Fig 13 3...

Страница 29: ...ing sides to the assemblies next to it fig 13 5 Note The distance between assemblies should be 12 fig 13 6 Note Refer to previous page fig 13 2 and 13 3 for attaching trellis clip Step 13 Attach Trellis End Assemblies Part 2 Hardware 32 x 10 x 4 Wood Screw 16 x 10 x 1 1 4 Pan Screw Fig 13 6 Fig 13 5 Start here and move outwards on either side alternating trellis assemblies so Trellis Clip varies f...

Страница 30: ...posing corners Attach a 194 Arch Gusset Left on the other two corners B Repeat for opposite side Step 14 Attach Left and Right Arch Gussets Part 1 193 Arch Gusset Right Fig 14 1 194 Arch Gusset Left 2 x 193 Arch Gusset Right 36 x 127 x 453 2 mm 2 x 5 x 17 27 32 2 x 194 Arch Gusset Left 36 x 127 x 453 2 mm 2 x 5 x 17 27 32 Hardware Wood Parts 8 x 8 x 2 1 2 Wood Screw 4 x 8 x 3 Wood Screw Fig 14 2 8...

Страница 31: ...o Panel Posts using one 8 x 3 Wood Screw and to 301 Beam 81 1 2 with two 8 x 2 1 2 Wood Screws as shown in fig 14 3 and 14 4 Each corner of the assembly should have one Arch Gusset Right and one Arch Gusset Left 193 Arch Gusset Right Fig 14 3 Hardware Wood Parts Fig 14 4 Step 14 Attach Left and Right Arch Gussets Part 2 2 x 193 Arch Gusset Right 36 x 127 x 453 2 mm 2 x 5 x 17 27 32 2 x 194 Arch Gu...

Страница 32: ...32 support yardistrystructures com NOTES ...

Страница 33: ...33 support yardistrystructures com NOTES ...

Страница 34: ...his product for ease of assembly Excellent Very Good Average Below Average Poor How would you rate our instructions Excellent Very Good Average Below Average Poor How would you rate the quality of packaging Excellent Very Good Average Below Average Poor Would you recommend the purchase of our products to friends and family Yes No Comments MM DD YY REVISION 10 18 11 MAIL TO Yardistry c o Solowave D...

Отзывы: