background image

 

 

 
 
 

Product Code : 

2040039 

Description : 

LAN TEST

 

 

QUBIX S.p.A. Networking solutions 

– Via Canada, 22/A – 35127 Padova – Italy 

Tel. +39 049 7801994 

– Fax +39 049 775667 – 

http://www.qubix.it

 

 

Rev. 05-12 

Qubix S.p.A. si riserva di apportare modifiche e migliorie in qualsiasi momento senza preavviso 
 Qubix S.p.A. reserves the right to make changes and improvements at any time without notice
 

 

 

Description

 

 

LANtest is a handheld tool that allows network professionals to quickly and easily check the integrity of balanced twisted-pair cables and 
connections in Ethernet networks. In one step LANtest checks: opens, shorts, reversed pairs, crossed and split pairs in balanced twisted 
pair cables. Just put the switch in the On position, press the TEST button and LANtest automatically scans the pairs, looking for mistakes 
and failures. The remote unit allows for an accurate verification of the connections in data networks. 

 
 

Packaging

 

 

 

1 Lantest 

 

1 LANtest REMOTE 

 

Patch cord RJ45-RJ45 

 

User manual 

 

Protective case

 

 
 
 
 
 
 
 
 
 
 

Functionality

 

 

 

It checks the nonconformity of cables, jacks, plugs and connections and detects: opens, shorts, crossed pairs, reversed pairs and split 
pairs (to identify split pairs it requires a minimum cable length of 40 cm)

 

 

It checks the integrity of the shielding

  

 

The  remote identifier allows a precise identification of the causes of anomalies

  

 

Easy to read fault indicator (LED) and very rapid test

 

 

Auto standby mode to reduce power consumption

 

 
 

Batteries

 

 

LANtest runs on 4 AAA alkaline batteries of 1.5 volts. The battery LED will light when it detects the condition of low batteries.  
The use of LANtest with low batteries can affect the accuracy of tests. If LANtest 

is not used for over a month it’s better to

 remove the 

batteries.

 

 
 

Recommendations

 

 

Do not connect  LANtest  to active circuits, the 2 units could be damaged. Radio frequency electromagnetic fields of high intensity can 
cause erroneous readings. Do not open the two units or try to repair them in case of failures.  
In case of malfunction, return the instrument to a local distributor by filling out the type of fault founded.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 