28
29
TROUBLESHOOTING
WARNING:
Before performing any repair work, always ensure that the battery pack
has been removed.
WARNING:
Always wear heavy duty gloves when adjusting or cleaning, especially
when handling sharp objects.
Fault/malfunction Cause
Remedy
Mower fails to start
Safety key is not inserted
Insert safety key
Battery is not correctly inserted Remove the battery and reinsert
Mower standing in high grass
Start motor on shorter grass or
already mowed area, change cutting
height if necessary
The mower housing is clogged
Clean housing so that the blade can
move freely
Battery has no power
Check and recharge battery
Mower stops working
/loses power
Cutting height is incorrect
Adjust the cutting height
Cutting blade is worn or
damaged
Replace with new blade from dealer
service centre
Battery performance
decreasing
Check the battery performance and
charge it if necessary
Grass bag is not filled
sufficiently
Cutting height is too Low
Adjust and increase cutting height
The lawn / grass is wet
Allow the lawn to dry
Underside of the mower deck
is clogged.
Clean the underside of the mower
deck
Cutting blade is worn or dam-
aged.
Replace it by contacting the custom-
er service centre
Mower vibrating at
higher speed
Cutting blade is unbalanced
Balance the blade by grinding each
cutting edge until equal
Blade is Loosened /incorrectly
fitted
Tighten the blade bolt
Mower cuts unevenly The blade is damaged
Blade is assembled incorrectly
Sharpen the blade or replace
Re-assemble blade correctly
DECLARATION OF CONFORMITY
To the provisions of Council Directives
We
MEROTEC GmbH
Otto-Brenner-Str. 8
47877 Willich, Germany
Declare that the product:
Machine Description: 40V CORDLESS LAWNMOWER
LM G46E/ Y0JZ-SP02-4640
Function: Cutting grass
Complies with the essential health and safety requirements of the following directives:
Supply of Machinery (Safety) Regulations 2008
Electromagnetic Compatibility Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic
Equipment Regulations 2012
Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001
Relative Notified Body (GB/8500/0184/21 Issue 1):
AnP Certification Limited
2, Parkfield Street Manchester M14 4PN
Measured Sound Power Level (L
wA
): 92.4 dB(A), K=3 dB(A)
Measured Sound Pressure Level (L
pA
): 81 dB(A), K=3 dB(A)
Declared Guaranteed Sound Power Level: 96 dB (A)
Standards and technical specification referred to :
EN60335-2-77:2010
EN 60335-1:2012+A11+A13+A1+A14+A2
EN62233:2008
EN55014-1:2017
EN55014-1:2006+A1+A2
EN55014-2:2015
EN50581:2012
Authorized Signatory
Date:
24.0
7
.2021
Signature:________________________
Place: York
Name: Mariana Hall
General Manager
SUMEC UK
Unit A&B Escrick Business Park Escrick
York YO19 6 FD, United Kingdom