22
23
TROUBLESHOOTING
Fault/malfunction
Cause
Remedy
Motor does not start
up
The mains plug is not correctly
plugged in.
Check that the mains plug is fitted
properly.
The socket does not supply
any power/the fuse has blown
or the RCCB has tripped.
Check the power cable for damage.
The button on the safety
switch was not pushed.
Let go of the safety bar and push the
button on the safety switch before
pulling the safety bar again.
The motor overload protection
has triggered, the motor is
overheated.
Allow the device to cool down for
15-20 minutes.
Unsteady run
The device emits
unusual
noises Insufficient
power
The selected cutting height is
too low.
Set the cutting height 2 levels
higher.
Collecting bag is full to the
rim or the discharge chute is
clogged.
Empty the collecting bag and
remove cuttings from the
discharge chute.
Blade is blocked by foreign
object.
Check the blade
compartment for foreign
objects and remove these if
present.
Blade is dull or damaged.
Check the blade and have it
sharpened or replaced at a
specialist workshop, if
necessary.
Cuttings left on
ground
Collecting bag is full to the
rim or the discharge chute is
clogged.
Empty the collecting bag and
remove cuttings from the
discharge chute.
Grass is too wet.
Wait for the grass to dry.
DECLARATION OF CONFORMITY
To the provisions of Council Directives
We
MEROTEC GmbH
Otto-Brenner-Str. 8
47877 Willich
Germany
Declare that the product:
Machine Description: Electric lawnmower
EM N34A/ SLM 34L
Function: Cutting grass
Complies with the essential health and safety requirements of the following directives:
Machinery Directive 2006/42/EC
Electromagnetic Compatibility Directive 2014/30/EU
EC Directive 2011/65/EU and its amendment Directive (EU) 2015/863 (RoHS)
Noise Emission in the Environment by Equipment for Use Outdoors Directive
2000/14/EC amended by 2005/88/EC
We additionally confirm the following in accordance with the 2000/14/EC amended by 2005/88/EC emis-
sions guideline,
Conformity Assessment Procedure as Per Annex III,
TÜV Rheinland LGA Products GmbH - Tillystraße 2 -90431 Nürnberg
Notified under No. 0197
Measured Sound Power Level: L
wA
= 94.58 dB(A), K=1.72 dB(A)
Declared Guaranteed Sound Power Level: 96 dB (A)
Standards and technical specification referred to :
EN 60335-2-77:2010
EN 60335-1: 2012+A11+A13+A1+A14+A2+A15
EN 62233:2008
EN IEC 55014-1:2021
EN IEC 55014-2:2021
EN IEC 61000-3-2:2019+A1
EN 61000-3-3:2013+A1+A2
EN 50581:2012
Authorized Signatory
Date:
21.01.2023
Signature:________________________
Place:
Willich
Name:
Roland Menken
General Manager
MEROTEC GmbH