System Specifications
Items
Model Number
Remarks
KMG65E-S3
KMG65E-K3
KMG65E-S6
KMG65E-K6
Quantity of
Connected Power
Box(es)
—
1
2
Continuous
Output
kVA
3.0
6.0 (3.0 and 3.0)
kW
3.0
6.0 (3.0 and 3.0)
Power Factor
—
1.0
Maximum Output
kVA
3.2
6.4 (3.2 and 3.2)
Output for Engine
Speed
Start / Stop
—
ON / OFF Switch on Control Panel
Warning Signal
LED Light
ON
Generator Temperature (Stator)
Power Box Temperature
Overload
Insufficient Engine Speed
Self Protection Function
Auto Stop for Overheat and Overload
Engine Speed Versus Power Output
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
0
500
1000
1500
2000
2500
3000
3500
Engine Speed
O
ut
pu
t
A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Outpu
tkV
A
Maximum output
Continuous output
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
0
500
1000
1500
2000
2500
3000
3500
Engine Speed RPM
Overload
O
ut
pu
t
A
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Outpu
tkV
A
Maximum output
Continuous output
Maximum output
Continuous output
POWER CAN BE SUPPLIED
SPEED IS INSUFFICIENT
0004622
Figure 1
SPECIFICATIONS
40
KMG65E Operation Manual
Содержание KMG Series
Страница 1: ...KMG series OPERATION MANUAL KMG65E S3 KMG65E S6 KMG65E K3 KMG65E K6 MARINE GENERATOR P N 0AKMG G00100 ...
Страница 14: ...This Page Intentionally Left Blank SAFETY 10 KMG65E Operation Manual ...
Страница 26: ...This Page Intentionally Left Blank PRODUCT OVERVIEW 22 KMG65E Operation Manual ...
Страница 32: ...This Page Intentionally Left Blank OPERATION 28 KMG65E Operation Manual ...
Страница 42: ...This Page Intentionally Left Blank TROUBLESHOOTING 38 KMG65E Operation Manual ...