9. Cooling water system
173
(4) Attaching the delivery nozzle (outlet)
• Make a fixing hole of Ø21 or less for attaching the
nozzle. The hose attached at the nozzle should be
1.8 m or less and should reach without any strain,
therefore care should be taken in deciding on the
best position.
• Fix the nozzle (outlet) in place and attach on the
discharge side of the pump.
(5) Attaching the hose
• Attach the hose from the strainer to the pump inlet.
• Attach the delivery nozzle hose to the pump outlet.
• Make the hose as short as possible and avoid sharp bends.
(6) Test operation
• Collect water in the bottom of the boat, and check for any problems with the hose or siring. After
doing this, connect the battery.
• Turn on the pump switch, and check to see that water is being taken in and discharged properly.
The pump will stop automatically when there is no water left.
• If the inside of the pump is dry, or if the water is not being drawn up initially after a period of 10
seconds, lift the strainer above the water surface and stop the pump. Prime the pump before
starting it up again.
(7) Fixing the strainer
• After the test operation, fix the strainer into place with screws.
(Be careful not to damage the bottom of the boat with the screws.)
Fixing hole
Delivery nozzle
Hose
21