COMPRESSOR MODEL 

HP 

VOLTAGE 

HERTZ 

PHASE 

PART # 

TECUMSEH AJB2433ZXA 

115 

50/60 

AJB24-115 

TECUMSEH AJB2433ZXD 

208/220/230 

50/60 

AJB24-208 

EMBRACO FFI12HBX 

1

/

3

 

115 

50/60 

FF12-115 

DANFOSS SC15FTX 

1

/

3

 

115 

50/60 

SC15-115 

DANFOSS SC18FTX 

1

/

2

 

208/220/230 

50/60 

SC15-208 

 

TEMPERATURE CONTROL PARTS 

PART # 

FDC 4000 

4000 

FDC nCOMPASS 

nCOMPASS 

 

CASCADE ELECTRICAL PARTS 

PART # 

Heater Harness No. H-200 

217-VOLTAGE 

Refrigeration Switch No. 2X464 

TOGGLE 

Condenser Fan Motor No. GE-5411 - 115/60/1 

500-115 

Condenser Fan Motor No. GE-5421 - 230/50-60/1 

500-VOLTAGE 

Electrical Cord No. 8-3 

(Please Specify Voltage)

 

PWRCRD-VOLTAGE 

Control Board No. CECB2TUV 

(Please Specify Voltage)

 

231-VOLTAGE 

 

REFRIGERATION HIGH STAGE PARTS 

PART # 

Air Cooled Condenser No. 3CZ0602B 

254 

Drier No. C-053-S 

256H 

Capillary Tube 

HS-17, HS-20 

Oil Separator, Temprite Series 900 

(If Applicable)

 

900 

 

REFRIGERATION LOW STAGE PARTS 

PART # 

Pressure Control No. 20PS01-0039 

259 

Receiver Condenser 

RCN-LS 

Drier No. CO-52S-S 

256L 

Capillary Tube 

LS-28, LS-31 

Oil Separator, Temprite Series 900 

(If Applicable)

 

900 

 

HARDWARE PARTS 

PART # 

Latch No. METL-L1-99 

REX37L1-3 

Chest Hinge 

59-928M 

Upright Hinge No. Polar 109-LH 

59-928U 

Cabinet Gasket 

NX504B1 

Lid or Door Gasket 

PSOS 

Grill No. 650H 

356F, 356S 

Sub-Lids 

(Must have Model Number)

 

SL-MODEL NUMBER 

Inner Door 

(Must have Model & Serial Number)

 

357-MODEL NUMBER-SERIAL NUMBER 

Clips & Rollers for Inner Doors 

(Quantity 10 minimum)

 

405 

Shelves for Freezer 

(Must have Model Number)

 

4015-MODEL NUMBER 

 

16

 

REPLACEMENT PARTS LIST 

Содержание ULF Series

Страница 1: ...r of Yamato Scientific To use this unit properly read this Instruction Manual thoroughly before using this unit Keep this instruction manual around this unit for referring at any time WARNING Carefully read and thoroughly understand the important warning items described in this manual before using this unit Yamato Scientific America Inc Santa Clara CA ...

Страница 2: ... REFRIGERATION SPECIFICATIONS 4 MAINTENANCE 5 UNIT OPERATION 6 TEMPERATURE CONTROL 7 ALARM OPERATION 8 ALARM SYSTEM 8 DRY CONTACT RELAY 8 CONTROL PROGRAMMING 9 CONTROL KEYS DISPLAYS 9 CONTROL PROGRAMMING 10 CONTROL KEYS DISPLAYS CONT 10 USER PARAMETER MODE 10 PROGRAM PARAMETER MODE 11 CALIBRATION PROCEDURE 12 WIRING DIAGRAM 13 ALARM WIRING DIAGRAM 14 REFRIGERATION FLOW CHART 15 REPLACEMENT PARTS L...

Страница 3: ...EXCLAMATION POINT CAUTION REFER TO ACCOMPANYING DOCUMENTS 1 Move the freezer to an indoor location and plug the freezer into an appropriate outlet with an adequate power supply Consult your maintenance department for additional information on the proper electrical configuration for this unit 2 Once plugged in the compressor s will start to operate and pull down to the setpoint on the temperature c...

Страница 4: ...lly present on the mains supply overvoltage category II Pollution degree 1 WARNING THIS FREEZER IS PROVIDED WITH AN INPUT CIRCUIT PROTECTIVE DEVICE WHICH SHALL BE MAINTAINED AND SERVICED BY QUALIFIED PERSONNEL ONLY CAUTION FUSES OR BREAKERS USED INSIDE PROTECTIVE DEVICE 15A OR 20A 250V TIME DELAY CAUTION UNPLUG FREEZER BEFORE ANY TECHNICAL SERVICE IS PERFORMED ON THE UNIT WARNING DO NOT POSITION E...

Страница 5: ...edicated Electrical Line MODEL VOLTAGE AMPERAGE PLUG ULF401U ULF501U ULF601U ULF701U 115 VOLTS 60 HERTZ 1 PHASE 20 AMP DEDICATED LINE NEMA 5 20 WARNING ONLY PLUG THIS UNIT INTO THE PROPER OUTLET DO NOT ATTEMPT TO MODIFY PLUG IN ANY WAY IMPROPER USE OF THE ELECTRICAL PLUG WILL VOID WARRANTY 3 GENERAL SPECIFICATIONS TEMPERATURE SPECIFICATIONS ELECTRICAL SPECIFICATIONS ...

Страница 6: ...4A 23 oz R170 30 to 20 psi R508B 130 psi ULF501U 18 1 HP TECUMSEH R404A 24 oz R170 30 to 20 psi R508B 130 psi ULF601U 22 1 HP TECUMSEH R404A 24 oz R170 30 to 20 psi R508B 130 psi ULF701U 25 1 HP TECUMSEH R404A 25 oz R170 30 to 20 psi R508B 130 psi 4 REFRIGERATION SPECIFICATIONS REFRIGERATION SPECIFICATIONS ...

Страница 7: ... in the freezer and store it in a back up freezer or elsewhere 2 Unplug the freezer and open the freezer front door lid 3 Use a cloth to protect the control from dripping water 4 Air out the freezer for at least 12 hours allowing the unit to reach room temperature 5 Take a rag and wipe up all the excess water in the unit melted frost 6 Plug the unit in and set your temperature to the desired setpo...

Страница 8: ...system cycles off on high pressure control WARNING ALWAYS LEAVE THE REFRIGERATION SWITCH IN ON POSITION AS THIS WILL AUTOMATICALLY ACTIVATE THE AUTOMATIC STARTING SYSTEM CAUTION COVER SCREEN ON BACK OF FREEZER MAY ONLY BE REMOVED BY AUTHORIZED PERSONNEL ONLY FOR CONNECTIONS TO THE EXTERNAL ALARM COVER SCREEN MUST BE REPLACED BEFORE PUTTING FREEZER INTO SERVICE FAILURE TO REINSTALL COVER COULD RESU...

Страница 9: ...ATURE SETPOINT The temperature set point can be changed by simply pressing the up arrow to raise or the down arrow to lower the temperature set point WARNING CHANGING THE CONTROL PARAMETERS OUTSIDE OF THE MANUFACTURE RECOMMENDED RANGE COULD SHORTEN THE LIFE SPAN OF YOUR EQUIPMENT OR CAUSE ISSUES RESULTING IN MECHANICAL FAILURE WARNING USE ONLY THE UP AND DOWN KEYS WHEN MAKING CHANGES ON THIS CONTR...

Страница 10: ...e batteries should be changed approximately every three years with lead acid rechargeable 1 2 Ah min model PS 640F1 or equivalent WARNING ALARM SYSTEM SHOULD BE TESTED EVERY 30 DAYS The dry contact relay is a terminal strip located on the back of the freezer RATING OF THIS CONNECTION 2A 125 VAC 2A 30 VDC RED NORMALLY CLOSED WHITE COMMON BLUE NORMALLY OPEN WARNING IF IT IS NECESSARY TO REMOVE METAL...

Страница 11: ...or 2 seconds and release to silence audible alarm under normal power or on battery power While unit is in an alarm condition the external alarm relay contacts will remain energized until the alarm condition no longer exists Press and hold to display chamber temperature while the controller is on battery power Chamber temperature will be displayed until key is released Alarm contact will remain ene...

Страница 12: ...utton is pressed to display the process value Note When operating on battery power the battery status LED labeled BAT on the front panel will be lit To enter the USER parameter mode hold the scroll key for 2 seconds and release To enter the user parameter mode hold the Scroll Button for 2 seconds and release To make changes in the user parameter mode press the up or down arrows To exit the user pa...

Страница 13: ...ential 22 12 X AHY 3 1 Alarm Hysteresis 1 8 1 0 X OHY 3 1 Output Hysteresis 3 6 2 0 X RB 1 Alarm Delay in Minutes 30 X DoR 4 Door Alarm X SP 2 Setpoint X IN2 4 N A N A TO EXIT TAP SCROLL KEY REPEATEDLY UNTIL TEMPERATURE SETPOINT SCREEN APPEARS 1 This parameter has been turned on by pressing either arrow key then make your changes in user mode THE VALUES TO BE CHANGED ARE DISPLAYED IN USER MODE ONL...

Страница 14: ...e value to ON PARAMETERS DESCRIPTION F C ON OFF SPL 3 Lower Setpoint SPH 3 Upper Setpoint Al 2 Alarm INV 1 Temperature Scale SHF 1 Calibration X Hold SCROLL KEY for 2 seconds and release SHF should appear in the top display and the current calibration value should appear in the bottom display The value can now be changed with UP or DOWN arrow keys Once finished press and release the SCROLL KEY to ...

Страница 15: ...13 WIRING DIAGRAM ...

Страница 16: ...14 ALARM WIRING DIAGRAM ...

Страница 17: ...15 REFRIGERATION FLOW CHART ...

Страница 18: ... Specify Voltage 231 VOLTAGE REFRIGERATION HIGH STAGE PARTS PART Air Cooled Condenser No 3CZ0602B 254 Drier No C 053 S 256H Capillary Tube HS 17 HS 20 Oil Separator Temprite Series 900 If Applicable 900 REFRIGERATION LOW STAGE PARTS PART Pressure Control No 20PS01 0039 259 Receiver Condenser RCN LS Drier No CO 52S S 256L Capillary Tube LS 28 LS 31 Oil Separator Temprite Series 900 If Applicable 90...

Страница 19: ...ditions This warranty shall have force and effect only if all items are used with proper circuits voltages and frequencies and the operation thereof is in accordance with instructions furnished by the manufacturer This warranty shall not extend to such parts as refrigerants finishes belts and dryers This warranty shall not extend to ordinary wear and tear or ordinary refrigeration service and refr...

Страница 20: ...re subject to a 25 restocking fee Shipping and handling cost are non refundable All retrofitted customized and special order item sales are final and non returnable In Case of Request for Repair If the failure occurs stop the operation turn OFF the power switch and unplug the power plug Please contact the sales agency that this unit was purchased or Yamato Scientific s sales office Check following...

Отзывы: