background image

YCO-130607

SPC - Solar 

Operation Manual

3

Calibration

     

Prepare "kilogram" check weights (more than OIML M1 class) corresponding to the capacity. It is not   

      possible to calibrate the SPC-Solar with either "pound" or "ounce" check weight. Be sure to calibrate the  

      scale under battery-powered mode.

   

   

Operation

Display

1

Install batteries.

Set the user parameter No. 01 (power select) at 001 

(battery-powered operation)

Press and hold the 

 

key and press the 

 

key to go 

to user parameter mode.

  

2

Press and hold the 

 

key and press the 

 

key to go 

to calibration mode 

  

3

After confirming, the stable indicator 

 

lights up, press 

the 

 

key.

  

4

Place a check weight corresponding to the scale 

capacity. 

SPC - Solar 2: 2,000 grams

SPC - Solar 5: 5,000 grams

  

5

When the stable indicator lights up, press 

 

key.

If the display shows as right figures, calibration has been 

completed successfully

If there is the following differences for the values in the 

right figures, turn off the power and try to calibrate it 

again

SPC - Solar 2: more than +/- 5 counts

SPC - Solar 5: more than +/- 10 counts

After calibration, turn off the power. Turn on the power 

again and confirm that correct weight value is displayed

  Capacity 2 kg

  

Capacity 5 kg

  

  

Содержание SPC - Solar

Страница 1: ...ings CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 www YamatoCorp com Solar Powered Portion Control Scale SPC Solar Operation Manual Read this manual before use and keep it handy ...

Страница 2: ... 5 g 5 475 lb 5 lb 7 5 oz 87 5 oz 2490 g System Parameter Operation Display 1 Press and hold the key and press keys to go to system parameter mode under the weighing mode The indicator blinks during system parameter indicator lights up 2 The operation under system parameter mode is as follows Move parameter No forward 1 Move setting value forward 1 Move setting value backward 1 Be sure to set the ...

Страница 3: ...000 02 Weighing units at power on 000 001 002 003 g lb Default oz lb oz 03 Checkweighing function 000 001 Disabled Enabled Default 04 Auto off timer 000 001 009 Disabled Set by one minute 5 minute Default 05 Gravity compensation 000 001 029 030 210 Disabled Prohibited to set Acceleration of Gravity m s2 9 7600 x 10000 5 30 offset Setting range 9 7600 to 9 8500 m s2 Minimum setting unit 0 0005 m s2...

Страница 4: ...d the key and press the key to go to calibration mode 3 After confirming the stable indicator lights up press the key 4 Place a check weight corresponding to the scale capacity SPC Solar 2 2 000 grams SPC Solar 5 5 000 grams 5 When the stable indicator lights up press key If the display shows as right figures calibration has been completed successfully If there is the following differences for the...

Страница 5: ...is message appears when the weighed value is over 5 divisions 2010g for the weighing capacity of 2000g When the item is removed the display returns to the weighing screen Make sure to use the scale within the capacity The initial error A Turned on the scale while a heavy item was placed Remove the item from the pan and then press the key The initial error B Turn on the scale while a foreign materi...

Страница 6: ...YCO 130607 SPC Solar Operation Manual Wiring Diagram 5 ...

Страница 7: ...YCO 130607 SPC Solar Operation Manual Parts List 6 ...

Страница 8: ...Box Holder 1 8 63900032 Battery Lid with sponge 1 9 63900023 Holding Plate CPU Board 1 10 63901034 Solar Panel 2 11 63900037 Membrane Key Switch 1 12 63900035 Front Mask SPC Solar 2 1 63910036 Front Mask SPC Solar 5 1 13 63910034 Solar Glass 2 14 63910033 Display Glass 1 15 63910021 Base 1 16 63910022 Rubber Foot 4 17 18 20 23 25 63911001 Hex Bolt SW M3X6 S S 17 19 63911002 Screw Washer M2X6 Batte...

Страница 9: ...nual YAMATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 www YamatoCorp com ...

Отзывы: