manualshive.com logo in svg
background image

30

Handling Precautions

Furnace may be cracked

Though the furnace may be cracked when it is used with high temperature, this does not affect the
use or performance of this unit.

Open/close door in high temperature affects the device

Do not open/close the door at in-oven temperatures of 500

or more, this affects the lifespan of

sensor, oven and heater. Quickly open/close it after operation if necessary.

Do not leave door open for a long time at high temperature

Leaving the door open for long time at high temperature may cause a radiation heat, which could
result in breakdown on the operation panel or controller.

Fine powder may fly

This unit uses an iron chrome heater.

Fine powder from its protective film (oxide film) may be

discharged into the air during operation. Protect the sample with a cover if needed.

Make protective film on heater

The heater used on this unit forms a protective film on its surface under high temperature. Make
the film by operating this unit for ten hours at the temperature of 1050

when using it under the

temperature of 700

or less.

Heater corrosion

The heater used on this unit can be corroded with halogen elements such as chlorine, fluorinate
or alkali metals such as sodium or potassium. Do not contact these materials to the heater.

Sensor deterioration

The sensor on this unit (R thermocouple) is very sensitive.

Do not contact it to samples when

loading or unloading them.

Do not touch the sensor with bare hands, which may cause

degradation.

Sensor corrosion

The sensor used on this unit can be corroded at high temperature with reducing substances such
as alkali metal, metal steam, metal oxide, carbon monoxide, carbon, phosphorus, selenium or
arsenicum or other reducing ambiences. Do not use these materials.

When using N2 gas…

Under the Atmosphere of N

2

gas, high temperature nitrides the surface of heater, which prevents

the formation of protective film on it. Upper limit temperature for use is, therefore, lower than that
under atmospheric air.

Use the temperature within the range of 100 to 900

when operating

this unit under N

2

gas.

Notes for overheating prevention device

In case there is a small difference between the set values of temperature for overheating
prevention device and that of controller, the overheating prevention device may be activated with
displaying

Er.19

when the temperature reaches to the set value of controller. Set the temperature

of overheating prevention device so it be at least 100

or higher than that of controller. (When

the setting temperature is lower, there is a case that overshoot occurs because this unit is high
temperature type furnace. This overheating prevention device should be used to protect the unit.)

·

The default value of the overheating prevention device at factory shipment is 1200

.

Содержание FO100CR

Страница 1: ...ng Muffle Furnace FO Series of Yamato Scientific Co Ltd To use this unit properly read this Instruction Manual thoroughly before using this unit Keep this instruction manual around this unit for refer...

Страница 2: ...ion 12 Quick Auto Stop Operation 13 Auto Stop Operation 14 Program Operation 18 Temperature Rise Fall Curve Reference 23 Program Operation 25 Other Functions 27 Handling Precautions 29 Maintenance Met...

Страница 3: ...ger of a problem that may cause a serious accident or even fatality CAUTION If the caution is ignored there is the danger of a problem that may cause injury damage to property or the unit itself Meani...

Страница 4: ...ution electrical shock Caution scald Caution no water heating Caution don t get wet Caution water only Caution deadly poison Prohibit Prohibit generally Prohibit inflammable Prohibit to disassemble Pr...

Страница 5: ...ction If this procedure is not followed fire or electrical shock may result Never perform repair work yourself since it is dangerous and not recommended Do not use the power cord if it is bundled or t...

Страница 6: ...e mode Be sure to connect this model to the specific power switchboard or receptacle for 115V FO110CR 210CR 310CR 410CR 510CR model is the 220V single phase mode Be sure to connect this model to the s...

Страница 7: ...ower switch is turned ON or OFF and fire explosion may result Refer to page 43 List of Dangerous Substances 4 Do not modify Modification of this unit is strictly prohibited This could cause a failure...

Страница 8: ...arthquake and the impact etc To prevent take measures that the unit cannot fall down and don t install in a busy place Touching the unit may cause a burn during and after the operation To prevent take...

Страница 9: ...7 Description and Function of Each Part Main Unit FO100CR Rear View Control panel Power cord Production plate Power switch ELB Specification plate Front View Fan Mounting hole for Exhaust opening...

Страница 10: ...taneously AUTO STOP Lamp Blinks while setting quick auto stop timer or auto stop timer Lights while quick auto stop timer or auto stop timer is running AUTO START Lamp Blinks while setting auto start...

Страница 11: ...emperature Setting Used for setting the temperature for each step in the program Sv 1 to Sv 30 is shown t 1 Program Time Setting Used for setting the time for each step in the program t 1 to t 30 is s...

Страница 12: ...temperature operation Pressing the TIMER key displays AS p The setting temperature SV can be set by pressing the ENTER key The operation time tim can be set by pressing it again Pressing the START STO...

Страница 13: ...11 Operation Method Operation Mode Function Setting Key and Characters The operation mode setting and function setting use the key operation and characters show in the following figure...

Страница 14: ...setting Also it displays the current setting temperature with blinking The FIXED TEMP lamp blinks too Set the temperature by pressing the 4 Start operation Press the orange START STOP key for about o...

Страница 15: ...stment is needed 2 Start timer operation Press the START STOP key for one second after deciding the time Timer operation starts with the FIXED TEMP and AUTO STOP lamps lighting on The timer is activat...

Страница 16: ...s the ENTER key again The measurement temperature display screen displays the character tim which indicates the timer setting The setting temperature display screen displays the current setting time w...

Страница 17: ...h the FIXED TEMP and AUTO STOP lamps lighting on Press the START STOP key to terminate the timer operation mode The screen returns to the initial setting screen To correct or check setting Changing th...

Страница 18: ...TO START lamp blinks too Set the temperature using the Press the ENTER key again The measurement temperature display screen displays the character tim which indicates the timer setting The setting tem...

Страница 19: ...heck setting Changing the setting temperature or time during operation is possible by pressing the TIMER key Use the to change the setting value Press the ENTER key respectively after changing the set...

Страница 20: ...rogram preparation form in pages 25 and 26 to check Check the temperature rise fall capability of the unit Set the time within the capability above Suppose for instance that in the unit which has capa...

Страница 21: ...surement temperature display screen displays the previous program mode Press the PROGRAM key again to display the next program mode Select the mode and press the ENTER key When PrG1 is selected the me...

Страница 22: ...the time check the temperature rise fall capability of unit For example about 10 minutes is needed to increase the temperature from room temperature to 600 for FO410C type 15 minutes for FO810C type...

Страница 23: ...e set in increments of a minute under 99 hours and 59 minutes It can be set in increment of ten minutes over 100 hours The can change the setting time quickly when it is pressed continuously Press the...

Страница 24: ...mperature screen indicates PS 7 in the example because repeat function is used at the seventh step The step number 1 to 7 can be input in the setting temperature display screen Enter the number 1 in t...

Страница 25: ...Temperature rising characteristics in FO100CR FO110CR 0 200 400 600 800 1000 1200 1400 0 5 10 15 20 25 30 35 Temperature falling characteristics in FO100CR FO110CR 0 200 400 600 800 1000 1200 1400 0...

Страница 26: ...teristics in FO410CR 0 200 400 600 800 1000 1200 1400 0 10 20 30 40 50 Temperature falling characteristics in FO410CR 0 200 400 600 800 1000 1200 1400 0 100 200 300 400 500 Temperature rising characte...

Страница 27: ...m Operation Programming Preparation Form 1 Please use this form by making copies Register with PrG1 PrG2 PrG3 PAt1 PAt2 PAt3 No Project Name Date Programmer Program Pattern 1150 1000 900 800 700 600 5...

Страница 28: ...PAt1 PAt2 PAt3 No Project Name Date Programmer Input Value Temperature Time min Repeat Function Step 1 To Times Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 Step 13...

Страница 29: ...The current temperature in furnace operation mode character and setting temperature of overheating prevention device are displayed on respective screens 2 Set the temperature for overheating preventi...

Страница 30: ...ature display screen falls by the setting temperature while the temperature on furnace rises When it is set to the minus side the temperature on the measurement temperature display screen rises by the...

Страница 31: ...a thunderstorm turn off the power key immediately then turn off the circuit breaker and the main power If this procedure is not followed fire or electrical shock may be caused About the amount of sam...

Страница 32: ...oration The sensor on this unit R thermocouple is very sensitive Do not contact it to samples when loading or unloading them Do not touch the sensor with bare hands which may cause degradation Sensor...

Страница 33: ...it breaker function 1 Connect the power cord 2 Turn the breaker on 3 Push the red test switch with a ballpoint pen etc 4 If there is no problem the master circuit breaker will be turned off Check the...

Страница 34: ...rts considering environmental protection The feature components of this unit and materials used are listed below Component Name Material Main body Body Steel Melamine Epoxy composite resin coating Sta...

Страница 35: ...ort circuit detection ALARM lamp lights on Er 02 appears Triac is in short circuit Make a call for service Heater disconnecting detection ALARM lamp lights on Er 03 appears Heater is disconnected Make...

Страница 36: ...ropriate power supply Heater is not turned off after reaching to preset value Bad condition of SSR Replace the part Bad condition of thermo regulator Thermal fuse blows out Bad condition of fan Replac...

Страница 37: ...les office Check following items before contact Model Name of Product Production Number Purchase Date About Trouble in detail as possible Minimum Retention Period of Performance Parts for Repair The m...

Страница 38: ...wer failure Calibration offset RS485 communication function Safety device Earth leakage circuit breaker Overheating prevention device Self diagnostic functions Sensor error Memory error Heater Iron ch...

Страница 39: ...et RS485 communication function Safety device Earth leakage circuit breaker Overheating prevention device Self diagnostic functions Sensor error Memory error Heater Iron chrome wire Cantal AF 1KW 1 5K...

Страница 40: ...FO110CR 210CR 310CR 410CR 510CR Time up Alarm output terminal 281301 All models Output terminal for measured temperature transmission 4 20mA 281302 All models N2 gas leading device 281303 All models...

Страница 41: ...115V FO110CR 210CR 310CR 1 2 T2 RS485 3 4 A A CN5 1 SSR 3 4 2 3 3 2 1 CN2 CN1 1 2 3 2 1 CN4 4 5 6 X CONT 18 1 18 1 PIO 1 18 1 18 CN8 CN9 CN1 CN2 1 2 3 2 1 TB1 TB2 TH TM1 1 2 3 4 X 2 1 5 6 CT FM H1 H2...

Страница 42: ...2 3 2 1 CN1 CN2 1 2 3 3 2 1 4 3 SSR 2 X 4 3 2 1 TM1 1 CN5 A A 4 3 RS485 T2 2 1 H2 H1 FM AC220V ELB Symbol Part name Symbol Part name ELB Earth leakage breaker X Main relay T1 T2 Terminal block FM Fan...

Страница 43: ...JA04529 KD L2123 30A 30mA YSJ CT 2170010005 CTL 6 S H YSC FO100CR Part Name Code No Specification Manufacturer Heater panel SJA06711 Cantal AF 500W 110V 2 YSJ Fan motor SJA24593 SJ1225HA1BAT YSJ Main...

Страница 44: ...X 116F 2 220AL1HSTFW YSJ FO310CR Part Name Code No Specification Manufacturer Heater panel Cantal AF 1000W 110V 2 YSJ Fan motor SJA24488 SJ1225HA2BAT YSJ Main relay SJA06060 JQX 116F 2 220AL1HSTFW YSJ...

Страница 45: ...te Ammonium perchlorate and other perchlorate Potassium peroxide Sodium peroxide Barium peroxide and other inorganic peroxide Potassium nitrate Sodium nitrate Ammonium nitrate and other nitrate Sodium...

Страница 46: ...r breakdown may result in Note The contents of this document may be changed in future without notice Any books with missing pages or disorderly binding may be replaced Instruction Manual MUFFLE FURNAC...

Отзывы: