Yamato DSR-400 Скачать руководство пользователя страница 2

YCO-1105-06-02

DSR-400

Operation Manual

I. Introduction

1

II. Specifications

1

III. Operation

1

A. Control Panel

1

B. Power

2

C. Turning the Scale On and Off

2

D. Zero the Display

2

E. Unit Selection

2

F. Weighing

3

1. Basic Weighing

3

2. Net Weighing

3

3. Batch Weighing

4

V. Troubleshooting and Error Messages

4

Table of Contents

SAFETY INSTRUCTIONS

Before using the scale, carefully read, understand, and follow the “Safety Instructions” described in this manual.  Observe the advice given in

the “Operations” section to ensure proper operation.  Keep this operation manual handy for reference.

1)

This scale is 

not

 an explosion-proof model.  Do not use the scale in an atmosphere containing flammable gases or explosive fumes.  A fire or an explosion can result.

2)

Do not operate the scale if there is smoke or a burnt smell coming from the scale.  Remove the batteries or unplug the AC adaptor immediately.  After making sure that there is no
danger, consult your dealer.

  Never try to repair the scale by yourself.

3)

Never step on or sit on the scale.  Not only will the scale be damaged, but you may also be injured.

4)

Place the item to be weighed in the center of the platform.  Items placed on the edge of the platform may fall off and cause injury.

5)

When weighing a heavy, large or unbalanced item, make sure the item is stable on the platform, otherwise, an accident may occur.

6)

When carrying or moving the scale, be sure to hold it by the bottom of the base with both hands.  If you hold it by the platform, the platform or the platform support may become
detached causing the scale to fall.  This will damage the scale.  The platform is designed for easy removal and clean-up.

7)

Do not insert your finger into the gap or holes in the scale.  You may be injured.

8)

The DSR-400 uses a liquid crystal display.  If the LCD breaks and the liquid leaks from the LCD, do not touch it with your fingers.  The liquid is toxic if ingested.  Be especially careful
around small children.

To prevent damage to the scale

1)

Do not push the indicator or keys with sharp objects.  They may break or puncture the switch membrane panel.

2)

Use the specified power supply and choose a suitable environment.  If you do not, the weight readings may be inaccurate and the scale may be damaged.

3)

The scale is a sensitive weighing instrument, avoid physical shocks.  If you drop something on the scale, step on the platform, or drop it, the scale may be damaged and lose
accuracy.

4)

If the scale becomes dirty, wipe it with a soft cloth.  For stubborn stains, apply a little neutral detergent and then wipe the scale with a dry cloth.  Do not use thinner, benzene, hot
water, or chemical agents, all of which can cause deformation, discoloration, or deterioration of the scale.

5)

Never remove the case.  The fine adjustment section may be damaged and you may be injured by sharp edges on the internal parts.

6)

Do not place the scale upside down except when replacing the batteries.

7)

When a low battery condition occurs, replace all of the batteries.  When installing the batteries, install them according to the polarity markings in the case (+, -).  If the scale will not be
used for a long period, remove the batteries.

To keep the scale working efficiently

1)

Place the scale on a flat stable surface that will support the scale and the load.

2)

Do not place the scale in an area exposed to direct sunlight or to wind currents from an air conditioner, otherwise, the weights will not be accurate.

3)

Do not place the scale near machines that create vibrations or electromagnetic disturbance, such as microwave ovens, portable phones, or large motors.  This will affect the accuracy.

4)

The operating temperature range is from –5 C to +104 C (32°F to 104°F).  Do not subject the scale to sudden temperature changes; allow the scale to adjust to the new temperature
before use.

5)

This scale is not waterproof or dustproof.  Do not expose the scale to splashing water.  Do not install the scale in an extremely humid or dusty environment.

6)

If the scale is sealed, do not break the seal.  If you break the seal, the scale will not be considered legal for trade.  In this case, contact your dealer.

7)

Do not disassemble or modify the scale, you will void the warranty.

Содержание DSR-400

Страница 1: ...YCO 1105 06 02 YAMATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 ...

Страница 2: ...1 Do not push the indicator or keys with sharp objects They may break or puncture the switch membrane panel 2 Use the specified power supply and choose a suitable environment If you do not the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the platform or drop it the scal...

Страница 3: ...ires six AA size batteries or AC input when using the AC adaptor Operating temperature 32 F to 104 F 0 C to 40 C III Operation III A Control Panel 1 LCD Display Displays weight reading and error messages 2 Unit Selection Key Press to toggle between lb kg indications 3 Net Gross Key Press to toggle between Net Gross weight 4 ON ZERO Key Turns the power on and zeroes the display TARE Tares off the w...

Страница 4: ...capability The current mode of the scale is indicated by the arrow heads in the LCD display To toggle between the two modes press the lb kg key III C Turning the Scale On and Off Remove everything from the platform surface and press the ON O T key The display will briefly display four eights After approximately three seconds the display will automati cally set to zero Press lb kg N G keys simultan...

Страница 5: ...sic Weighing 1 Begin with no load on the scale and the display reading zero 2 Place an empty container on the scale platform wait for the indication to stabilize and press the ON O T key The weight of the container will automatically be deducted the display will read zero 3 Place the item s to be weighed in the container The weight displayed will be the net weight 4 To toggle between the net and g...

Страница 6: ...tinues to show all 8s after the scale is turned on The scale will not power on The keyboard does not func tion The displayed weight fluctuates excessively Possible Cause Vibration or an unstable position or platform AC adapter malfunction Power board malfunction CPU board malfunction Keyboard connector loose Keyboard connector damaged Keyboard damaged CPU board malfunction Weighing assembly in con...

Отзывы: