5
Safety Precautions
Installation and Preparation for Use
Warning
3
.
Choose a correct power distribution board or receptacle.
Choose a correct power distribution switchboard or receptacle that meets the oven’s
rated electric capacity.
Electric capacity : DE410 AC200V three-phase 8.3A
DE610 AV200V three-phase 11.5A
DT410 AV200V three-phase 11.5A
DT610 AV200V three-phase 16.0A
DE410U AV200V three-phase 8.3A
DE610U AV200V three-phase 11.5A
4.Supply connections for the oven
・
Request the supply connection for the shingle-phase 220V specifications from a
licensed electrician.
・
The special knowledge and skill are required for connecting. Failure to have this
operation complete by certified personnel will cause a fire or electrical shock during
oven operation.
5.Do not use the unit in an area where there is flammable or explosive gas.
Never use the unit in an area where there is flammable or explosive gas. The unit is not
explosion-proof. An arc may be generated when the power switch is turned ON or OFF,
and fire/explosion may result.
Explosive gas
Flammable gas