background image

Digital Controller SIO Driver

GP-Pro EX Device/PLC Connection Manual

96

Cable Diagram 4

Display

(Connection Port)

Cable

Remarks

GP3000

*1

 (COM1)

AGP-3302B (COM2)
ST

*2

 (COM2)

LT (COM1)

*1

All GP3000 models except AGP-3302B

*2

All ST models except AST-3211A and AST-3302B

4A

COM port conversion adapter by Pro-face.

CA3-ADPCOM-01

+

Connector terminal block conversion adapter by Pro-face

CA3-ADPTRM-01

+

User-created cable

Cable length:

500m or less

4B

User-created cable

GP3000

*3

 (COM2)

*3

All GP3000 models except the GP-3200 Series and AGP-3302B

4C

Online adapter by Pro-face

CA4-ADPONL-01

+

Connector terminal block conversion adapter by Pro-face

CA3-ADPTRM-01

+

User-created cable

4D

Online adapter by Pro-face

CA4-ADPONL-01

+

User-created cable

IPC

*4

*4

Available only with COM ports that support RS-422/485 (2wire).

)

„

 IPC COM Port (page 7)

4E

COM port conversion adapter by Pro-face.

CA3-ADPCOM-01

+

Connector terminal block conversion adapter by Pro-face

CA3-ADPTRM-01

+

User-created cable

4F

User-created cable

GP-4106  (COM1)

4G

User-created cable

GP-4107  (COM1)

4H

User-created cable

Содержание SDC10 Series

Страница 1: ...Controller SIO Driver 1 System Configuration 3 2 Selection of External Device 9 3 Example of Communication Setting 10 4 Setup Items 74 5 Cable Diagram 79 6 Supported Devices 138 7 Device Code and Address Code 152 8 Error Messages 156 ...

Страница 2: ...vice Select the model series of the External Device to be connected and its connection method 2 Selection of External Device page 9 3 Example of Communication Settings This section shows setting examples for communicating between the Display and the External Device 3 Example of Communication Setting page 10 4 Setup Items This section describes communication setup items on the Display Set the commu...

Страница 3: ...l block on the controller RS422 485 4wire Setting Example 4 page 16 Cable Diagram 2 page 81 RS422 485 2wire Setting Example 5 page 18 Cable Diagram 3 page 87 SDC25 26 C25 2 C26 2 Terminal block on the controller RS422 485 2wire Setting Example 6 page 20 Cable Diagram 6 page 114 SDC30 31 C30 040 C30 041 C31 045 C31 446 C31 546 Terminal block on the controller RS422 485 4wire Setting Example 7 page ...

Страница 4: ...etting Example 29 page 66 Cable Diagram 8 page 129 DMC10 DMC10 Terminal block on the controller RS422 485 2wire Setting Example 18 page 44 Cable Diagram 4 page 96 DMC50 DMC50CH20 DMC50CH40 DMC50CS20 DMC50CS40 Terminal block on DMC50MR20 Terminal block on DMC50ME20 RS422 485 4wire Setting Example 30 page 68 Cable Diagram 2 page 81 RS422 485 2wire Setting Example 31 page 70 Cable Diagram 3 page 87 D...

Страница 5: ...ing Example 25 page 58 Cable Diagram 3 page 87 DCP552 DCP552 2 Terminal block on the controller RS232C Setting Example 26 page 60 Cable Diagram 1 page 79 RS422 485 4wire Setting Example 27 page 62 Cable Diagram 2 page 81 RS422 485 2wire Setting Example 28 page 64 Cable Diagram 3 page 87 CMC10B CMC10B Communications connectoronthehost side RS422 485 4wire Setting Example 32 page 72 Cable Diagram 7 ...

Страница 6: ...y devices are connected 1 Up to 15 units can be connected if the External Devices include DMC10 or DMC50 2 Up to 15 units can be connected if the External Devices include DMC10 Note that DMC50 cannot be used For 1 n connection do not add termination resistors if the Controllers to be connected include any of the following series SDC15 SDC25 26 SDC35 36 DMC10 Display External Device Display Externa...

Страница 7: ...OM1 1 COM2 1 COM3 2 COM4 2 Set up the SIO type with the DIP switch Please set up as follows according to SIO type to be used COM3 2 COM3 2 PS 3711A COM1 1 COM2 2 COM2 2 COM2 2 PL 3000B PL 3600T PL 3600K PL 3700T PL 3700K PL 3900T COM1 1 2 COM2 1 COM3 COM4 COM1 1 2 COM1 1 2 DIP switch Setting Description 1 OFF 1 1 When using PS 3450A PS 3451A PS3000 BA and PS3001 BD turn ON the set value Reserved a...

Страница 8: ...ion to RD RXD None 7 OFF Short circuit of SDA TXA and RDA RXA Not available 8 OFF Short circuit of SDB TXB and RDB RXB Not available 9 OFF RS RTS Auto control mode Disabled 10 OFF DIP switch Setting Description 1 OFF Reserved always OFF 2 ON SIO type RS 422 485 3 ON 4 OFF Output mode of SD TXD data Always output 5 OFF Terminal resistance 220Ω insertion to SD TXD None 6 OFF Terminal resistance 220Ω...

Страница 9: ...al Device to be connected Select Yamatake Corporation Series Select the model series of the External Device to be connected and its connection method Select Digital Controller SIO Check the External Device that can be connected in Digital Controller SIO in system configuration 1 System Configuration page 3 Use System Area Not available in this driver Port Select the port of the Display to be conne...

Страница 10: ...amples of communication settings for the Display and the External Device which are recommended by Pro face 3 1 Setting Example 1 Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace To use SDC10 you need to set Wait To Send to 70ms or more ...

Страница 11: ...re 1 In operation mode press and hold the PARA key for 3 seconds to move to parameter mode 2 In parameter mode press and hold the PARA key for 3 seconds to move to setup mode 3 Press the PARA key several times to display the desired setup item 4 Use the Down Up keys to select a setting The set value will blink 5 When no operation is performed for 2 seconds the set value stops blinking and the chan...

Страница 12: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 13: ...setting display 2 In the parameter setting display press and hold the PARA key for 2 seconds to move to the setup display 3 Press the PARA key several times to display the desired setup item 4 Use the Down Up keys to select a setting The set value will blink 5 When no operation is performed for 2 seconds the set value stops blinking and the change is fixed 6 Press the mode key to move to the basic...

Страница 14: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 15: ... Procedure 1 In the basic display press and hold the ENT and Down keys simultaneously for 3 seconds or more to display the setup items 2 Press the Down Up keys to select a setup item and press the ENT key 3 Use the Down Up keys to select a setting and press the ENT key 4 Press the DISP key to move to the basic display Settings Setup Items Settings C31 1 C32 0 C33 0 The parameters to be set vary de...

Страница 16: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 17: ... Procedure 1 In the basic display press and hold the ENT and Down keys simultaneously for 3 seconds or more to display the setup items 2 Press the Down Up keys to select a setup item and press the ENT key 3 Use the Down Up keys to select a setting and press the ENT key 4 Press the DISP key to move to the basic display Settings Setup Items Settings C31 1 C32 0 C33 0 The parameters to be set vary de...

Страница 18: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 19: ... Procedure 1 In the basic display press and hold the ENT and Down keys simultaneously for 3 seconds or more to display the setup items 2 Press the Down Up keys to select a setup item and press the ENT key 3 Use the Down Up keys to select a setting and press the ENT key 4 Press the DISP key to move to the basic display Settings Setup Items Settings C31 1 C32 0 C33 0 The parameters to be set vary de...

Страница 20: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 21: ...s to move to the bank selection display 2 In the bank selection display press the enter key to move to the bank setup display 3 Press the para key several times to display the desired setup item 4 Press the enter key to blink the set value displayed 5 Use the Down Up keys to select a setting 6 Press the enter key to fix the change 7 Press the mode key to move to the operation display Settings Setu...

Страница 22: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 23: ... Procedure 1 In the basic display press the MODE key twice In the RUN READY mode switching display that appears change to READY mode 2 In the basic display press and hold the ENT and Down keys simultaneously for 3 seconds or more to display the setup items 3 Press the Down Up keys to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press ...

Страница 24: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 25: ... Procedure 1 In the basic display press the MODE key twice In the RUN READY mode switching display that appears change to READY mode 2 In the basic display press and hold the ENT and Down keys simultaneously for 3 seconds or more to display the setup items 3 Press the Down Up keys to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press ...

Страница 26: ...Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 27: ...s to move to the bank selection display 2 In the bank selection display press the enter key to move to the bank setup display 3 Press the para key several times to display the desired setup item 4 Press the enter key to blink the set value displayed 5 Use the Down Up keys to select a setting 6 Press the enter key to fix the change 7 Press the mode key to move to the operation display Settings Setu...

Страница 28: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 29: ...etails Procedure 1 In the basic display press the PARA key to display PARA Then press the ENT key to display rnry and move to READY mode 2 In the basic display press the PARA key several times to display SETUP 3 Press the ENT key to display the setup items 4 Press the Down Up keys to select a setup item and press the ENT key 5 Use the Down Up keys to select a setting and press the ENT key 6 Press ...

Страница 30: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 31: ...etails Procedure 1 In the basic display press the PARA key to display PARA Then press the ENT key to display rnry and move to READY mode 2 In the basic display press the PARA key several times to display SETUP 3 Press the ENT key to display the setup items 4 Press the Down Up keys to select a setup item and press the ENT key 5 Use the Down Up keys to select a setting and press the ENT key 6 Press ...

Страница 32: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 33: ...etails Procedure 1 In the basic display press the PARA key to display PARA Then press the ENT key to display rnry and move to READY mode 2 In the basic display press the PARA key several times to display SETUP 3 Press the ENT key to display the setup items 4 Press the Down Up keys to select a setup item and press the ENT key 5 Use the Down Up keys to select a setting and press the ENT key 6 Press ...

Страница 34: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 35: ...r details Procedure 1 In the basic display press the PARA key to move to setup mode 2 Press the ENT key to display the setup items 3 Press the Down Up keys to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items Settings C25 1 C26 0 C27 0 The parameters to be set vary depend...

Страница 36: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 37: ...r details Procedure 1 In the basic display press the PARA key to move to setup mode 2 Press the ENT key to display the setup items 3 Press the Down Up keys to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items Settings C25 1 C26 0 C27 0 The parameters to be set vary depend...

Страница 38: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 39: ...r details Procedure 1 In the basic display press the PARA key to move to setup mode 2 Press the ENT key to display the setup items 3 Press the Down Up keys to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items Settings C25 1 C26 0 C27 0 The parameters to be set vary depend...

Страница 40: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 41: ...ils Procedure 1 In the basic display press the PARA key to display PARA Then press the ENT key to display rnry and move to READY mode 2 In the basic display press the PARA key several times to display SETUP 3 Press the ENT key to display the setup items 4 Press the Down Up keys to select a setup item and press the ENT key 5 Use the Down Up keys to select a setting and press the ENT key 6 Press the...

Страница 42: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 43: ...ils Procedure 1 In the basic display press the PARA key to display PARA Then press the ENT key to display rnry and move to READY mode 2 In the basic display press the PARA key several times to display SETUP 3 Press the ENT key to display the setup items 4 Press the Down Up keys to select a setup item and press the ENT key 5 Use the Down Up keys to select a setting and press the ENT key 6 Press the...

Страница 44: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 45: ...ot the External Device 2 Click Set in the ladder software to display the setting screen 3 Click Model Setting from the menu and select the model No of the External Device 4 Click Environmental Setting from the menu and configure the setup transfer settings 5 Select Communication from Basic Function in the tree view and configure the communication settings 6 Transfer the settings to the External De...

Страница 46: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 47: ... key while holding down the FUNC key to move to the setting group selection screen 2 Press the PARA key several times to display the setup data setting group and press the ENT key 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items ...

Страница 48: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 49: ... key while holding down the FUNC key to move to the setting group selection screen 2 Press the PARA key several times to display the setup data setting group and press the ENT key 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items ...

Страница 50: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 51: ... key while holding down the FUNC key to move to the setting group selection screen 2 Press the PARA key several times to display the setup data setting group and press the ENT key 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items ...

Страница 52: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 53: ... key while holding down the FUNC key to move to the setting group selection screen 2 Press the PARA key several times to display the setup data setting group and press the ENT key 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display Settings Setup Items ...

Страница 54: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 55: ...er to your Controller manual for details Procedure 1 Press the RUN HOLD key while holding down the PROG key to move to READY mode 2 In the basic display press the SETUP key to move to the setup group 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display S...

Страница 56: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 57: ...er to your Controller manual for details Procedure 1 Press the RUN HOLD key while holding down the PROG key to move to READY mode 2 In the basic display press the SETUP key to move to the setup group 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display S...

Страница 58: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 59: ...er to your Controller manual for details Procedure 1 Press the RUN HOLD key while holding down the PROG key to move to READY mode 2 In the basic display press the SETUP key to move to the setup group 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display S...

Страница 60: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 61: ...er to your Controller manual for details Procedure 1 Press the RUN HOLD key while holding down the PROG key to move to READY mode 2 In the basic display press the SETUP key to move to the setup group 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display S...

Страница 62: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 63: ...er to your Controller manual for details Procedure 1 Press the RUN HOLD key while holding down the PROG key to move to READY mode 2 In the basic display press the SETUP key to move to the setup group 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display S...

Страница 64: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 65: ...er to your Controller manual for details Procedure 1 Press the RUN HOLD key while holding down the PROG key to move to READY mode 2 In the basic display press the SETUP key to move to the setup group 3 Press the Down Up keys several times to select a setup item and press the ENT key 4 Use the Down Up keys to select a setting and press the ENT key 5 Press the DISP key to move to the basic display S...

Страница 66: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 67: ...move to PARA bank mode 2 Press the para key to display RS 485 communication bank mode rS485 3 Press the enter key to move to RS 485 communication bank mode 4 Press the para key to select a setup item and press the enter key 5 Use the cursor keys to select a setting and press the enter key 6 Press the display key to move to the operation display 7 Reboot the External Device Settings Setup Items Set...

Страница 68: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 69: ...are 3 Select New Project from the Project menu 4 In the Project Group dialog box click OK to display the Project Definition dialog box 5 Type a project name in Project Name 6 Select the module you want to use from Module Type and then click OK 7 Select System Parameters Communication Setup Instance in the tree view 8 Set Trans Speed RS 485 port1 and Protocol RS 485 port1 on the Instance Body tab a...

Страница 70: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 71: ...are 3 Select New Project from the Project menu 4 In the Project Group dialog box click OK to display the Project Definition dialog box 5 Type a project name in Project Name 6 Select the module you want to use from Module Type and then click OK 7 Select System Parameters Communication Setup Instance in the tree view 8 Set Trans Speed RS 485 port1 and Protocol RS 485 port1 on the Instance Body tab a...

Страница 72: ... Setting of GP Pro EX Communication Settings To display the setting screen select Device PLC Settings from System setting window in the workspace Device Setting To display the setting screen click Setting of the External Device you want to set from Device Specific Settings of Device PLC Settings ...

Страница 73: ...ddress and transmission speed using the rotary switch on the front of the Controller as shown below After setting them reboot the External Device 2 Start the ladder software and select Setup 3 Select Communication Host in the tree view and set Data format as shown below 4 Select Write SLP10 to CMC10B from the Communication menu and download the set data to the External Device 5 Reboot the External...

Страница 74: ...evice PLC Settings from System setting window in the workspace Setup Items Setup Description SIO Type Select the SIO type for communicating with the External Device Speed Select the communication speed between the External Device and the Display Data Length Select a data length Parity Select how to check parity Stop Bit Select a stop bit length Flow Control Displays the communication control metho...

Страница 75: ...nd Enter the standby time ms from when the Display receives packets until it transmits the next command from 0 to 255 RI VCC Switches between RI VCC of the 9th pin To connect to the IPC you need to switch between RI 5V using the IPC selector switch Refer to your IPC manual for details Setup Items Setup Description Series Displays the model of the External Device Device Address Enter the address of...

Страница 76: ...or 1 page in the off line mode depends on the Display in use Please refer to the Reference manual for details Setup Items Setup Description SIO Type Select the SIO type for communicating with the External Device In the communication settings set SIO Type correctly according to the serial interface specifications of the Display If you select an SIO type that the serial interface does not support pr...

Страница 77: ...l Device enter how many times the Display retransmits the command from 0 to 255 Wait To Send Enter the standby time ms from when the Display receives packets until it transmits the next command from 0 to 255 Setup Items Setup Description Device PLC Name Select the External Device to set Device name is the title of the External Device set with GP Pro EX Initial value PLC Series Displays the model o...

Страница 78: ...t Settings Touch the External Device you want to set from the list that appears and touch Option Setup Items Setup Description RI VCC Switches between RI VCC of the 9th pin To connect to the IPC you need to switch between RI 5V using the IPC selector switch Refer to your IPC manual for details GP 4100 series do not have the Option setting in the off line mode ...

Страница 79: ...orm any short circuit loop in the system design Consult your External Device manual for the pin No on the External Device side It varies depending on the additional function If the communication is not stable because of noise or other factors connect an isolation unit Recommended cable Cable Diagram 1 Company Name Model Fujikura Densen Ltd Duplex IPEV S 0 9mm2 x 1P Triplex ITEV S 0 9mm2 x 1T Hitac...

Страница 80: ... TXD 3 RD RXD 2 SG 5 Signal name SD RD 4 ER DTR SG RS RTS CS CTS 7 8 DR DSR Pin D Sub 9 Pin socket Shield Controller FG Terminal Block 6 Display Signal name SD TXD RD RXD SG Signal name SD RD ER DTR SG RS RTS CS CTS DR DSR Shield Controller FG Terminal Block Display Display side Terminal block ...

Страница 81: ...ire IPC COM Port page 7 2A COM port conversion adapter by Pro face CA3 ADPCOM 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable Cable length 500m or less 2B User created cable GP3000 4 COM2 4 All GP3000 models except the GP 3200 Series and AGP 3302B 2C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADPT...

Страница 82: ...tance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield Terminal block RDA SDA RDB SDB SG FG RDA SDA RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Signal name Terminal block Signal name 150Ω 5 more than 1 ...

Страница 83: ...minal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Controller Display Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 D Sub 9 Pin socket Pin Shell Shield Terminal block Signal name RDB SDB SG FG RDA SDA Shield Terminal block Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Termina...

Страница 84: ...tance Controller 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance User created cable Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display RDA SDA Shield RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Signal name Terminal block C...

Страница 85: ...block Controller 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance User created cable CA4 ADPONL 01 Display Signal name RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 D Sub 9 Pin plug Pin Shell Shield Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Ter...

Страница 86: ...minal block Signal name RDB SDB SG FG RDA SDA Terminal resistance 1 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Controller Display Display side Terminal block Terminal resistance 1 Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Shield Terminal block Signal name RDB SDB SG FG RDA SDA Shield Terminal block Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2...

Страница 87: ...r less 3B User created cable GP3000 3 COM2 3 All GP3000 models except the GP 3200 Series and AGP 3302B 3C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable 3D Online adapter by Pro face CA4 ADPONL 01 User created cable IPC 4 4 Available only with COM ports that support RS 422 485 2wire IPC COM Port page 7 3E COM port c...

Страница 88: ...re than 1 2W Terminal resistance Terminal block Controller 150Ω 5 more than 1 2W Terminal resistance User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Terminal block Controller 150Ω 5 more than 1 2W Terminal r...

Страница 89: ...A 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller 150Ω 5 more than 1 2W Terminal resistance Display Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 D Sub 9 Pin socket Pin Shell Shield Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Terminal block Controller 150Ω 5 ...

Страница 90: ...re than 1 2W Terminal resistance Terminal block Controller 150Ω 5 more than 1 2W Terminal resistance User created cable Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Shield RDA SDA Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Terminal block Controller 150Ω 5 more than 1 2W Terminal r...

Страница 91: ... Terminal resistance Terminal block Signal name Controller 150W 5 more than 1 2W Terminal resistance User created cable CA4 ADPONL 01 Display RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 Shell Shield RDB SDB SG FG RDA SDA Shield RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Signal name D Sub 9 Pin plug Pin Terminal block Signal name Controller Terminal block Signal name Cont...

Страница 92: ...rminal block Controller more than 1 2W Terminal resistance 150Ω 5 Signal name RDB SDB SG TERM RDA SDA Signal name RDB SDB SG FG RDA SDA User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Terminal block Controll...

Страница 93: ...A 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller 150Ω 5 more than 1 2W Terminal resistance Display Signal name NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 ERB 9 CSB 6 FG DATA 1 D Sub 9 Pin socket Pin Shell Shield Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Terminal block Controller 150...

Страница 94: ...ON 4 ON Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Shield Signal name RDB SDB SG FG RDA SDA Terminal resistance 1 Terminal block Controller 150Ω 5 more than 1 2W Terminal resistance Display Display side Terminal block Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Shield Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA Terminal block Controller Terminal block Controll...

Страница 95: ...2W Terminal resistance Terminal block Controller 150Ω 5 more than 1 2W Terminal resistance Display Pin Signal name NC NC GND SG RS RTS 5V NC NC FG LINE LINE 3 8 1 2 5 4 6 7 9 Shell Display side D Sub 9pin plug Shield Signal name RDB SDB SG FG RDA SDA Shield Signal name RDB SDB SG FG RDA SDA 150Ω 5 more than 1 2W Terminal resistance Terminal block Controller Terminal block Controller 150Ω 5 more th...

Страница 96: ...r less 4B User created cable GP3000 3 COM2 3 All GP3000 models except the GP 3200 Series and AGP 3302B 4C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable 4D Online adapter by Pro face CA4 ADPONL 01 User created cable IPC 4 4 Available only with COM ports that support RS 422 485 2wire IPC COM Port page 7 4E COM port c...

Страница 97: ...istor is required Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG Shield DA DB SG Terminal block Signal name Controller Terminal block Signal name Controller User created cable ...

Страница 98: ...red Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 D Sub 9 Pin socket Pin Shell Shield DA DB SG Terminal block Signal name Controller Display SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 D Sub 9 Pin socket Shell Shield DA DB SG Shield DA DB SG Signal name Pin Terminal block Signal name Controller Terminal block Signal name Controller Display ...

Страница 99: ...istor is required Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG Shield DA DB SG Terminal block Signal name Controller Terminal block Signal name Controller User created cable ...

Страница 100: ... RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 D Sub 9 Pin plug Shell Shield DA DB SG Signal name Pin Terminal block Signal name Controller User created cable CA4 ADPONL 01 Display RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 Shell Shield DA DB SG Shield DA DB SG Signal name D Sub 9 Pin plug Pin Terminal block Signal name Controller Terminal block Signal name Controller User created cable...

Страница 101: ...istor is required Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG Shield DA DB SG Terminal block Signal name Controller Terminal block Signal name Controller User created cable ...

Страница 102: ...Signal name NC 3 DATA 2 5 NC 7 ERA 4 CSA 8 FG DATA 1 D Sub 9 Pin socket Pin Shell Shield DA DB SG Terminal block Signal name Controller Display ERB 9 CSB 6 GND SG NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 ERB 9 CSB 6 FG DATA 1 D Sub 9 Pin socket Shell Shield DA DB SG Shield DA DB SG Signal name Pin Terminal block Signal name Controller Terminal block Signal name Controller Display ...

Страница 103: ...tion resistor is required Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Shield DA DB SG Terminal block Signal name Controller Display Display side Terminal block SDA RDB SG ERA SDB ERB CSB RDA CSA Shield DA DB SG Shield DA DB SG Signal name Terminal block Signal name Controller Terminal block Signal name Controller Display Display side Terminal block ...

Страница 104: ...resistor is required In COM on the GP 4107 the SG and FG terminals are isolated Shield DA DB SG Terminal block Signal name Controller Display Pin Signal name NC NC GND SG RS RTS 5V NC NC FG LINE LINE 3 8 1 2 5 4 6 7 9 Shell Display side D Sub 9pin plug Shield DA DB SG Shield DA DB SG Terminal block Signal name Controller Terminal block Signal name Controller Display Pin Signal name NC NC GND SG RS...

Страница 105: ...r less 5B User created cable GP3000 3 COM2 3 All GP3000 models except the GP 3200 Series and AGP 3302B 5C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable 5D Online adapter by Pro face CA4 ADPONL 01 User created cable IPC 4 4 Available only with COM ports that support RS 422 485 2wire IPC COM Port page 7 5E COM port c...

Страница 106: ...than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA SG FG Shield SG FG 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance User created ...

Страница 107: ...erminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Display SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 Shield SG FG Shield SG FG Signal name D Sub 9 Pin socket Pin Shell 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal...

Страница 108: ...than 1 2W Terminal resistance Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance User created cable Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Shield RDA SDA SG FG Shield SG FG 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance User created ...

Страница 109: ...me D Sub 9 Pin plug Pin Shell Terminal block Signal name 150Ω 5 more than 1 2W Terminal resistance Controller User created cable CA4 ADPONL 01 Display RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 Shield SG FG Shield SG FG Signal name D Sub 9 Pin plug Pin Shell Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than...

Страница 110: ...than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA SG FG Shield SG FG 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance User created ...

Страница 111: ...erminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Display NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 Shield SG FG Shield SG FG Signal name D Sub 9 Pin socket Pin Shell 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resista...

Страница 112: ...Set Value 1 OFF 2 OFF 3 ON 4 ON SDA RDB SG ERA SDB ERB CSB RDA CSA Shield SG FG Signal name Terminal block Signal name Controller Terminal resistance 1 150Ω 5 more than 1 2W Terminal resistance Display Display side Terminal block SDA RDB SG ERA SDB ERB CSB RDA CSA Shield SG FG Shield SG FG Signal name Terminal resistance 1 Terminal block Signal name Controller Terminal block Signal name Controller...

Страница 113: ...ame Controller 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance Display Pin Signal name NC NC GND SG RS RTS 5V NC NC FG LINE LINE 3 8 1 2 5 4 6 7 9 Shell Display side D Sub 9pin plug Shield SG FG Shield SG FG 150Ω 5 more than 1 2W Terminal resistance Terminal block Signal name Controller Terminal block Signal name Controller 150Ω 5 more than 1 2W Terminal resista...

Страница 114: ...r less 6B User created cable GP3000 3 COM2 3 All GP3000 models except the GP 3200 Series and AGP 3302B 6C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable 6D Online adapter by Pro face CA4 ADPONL 01 User created cable IPC 4 4 Available only with COM ports that support RS 422 485 2wire IPC COM Port page 7 6E COM port c...

Страница 115: ...r is required Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG FG Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG FG Shield DA DB SG FG Terminal block Signal name Controller Terminal block Signal name Controller User created cable ...

Страница 116: ...SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 Shield DA DB SG FG Signal name D Sub 9 Pin socket Pin Shell Terminal block Signal name Controller Display SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 Shield DA DB SG FG Shield DA DB SG FG Signal name D Sub 9 Pin socket Pin Shell Terminal block Signal name Controller Terminal block Signal name Controller Display ...

Страница 117: ...r is required Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG FG Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG FG Shield DA DB SG FG Terminal block Signal name Controller Terminal block Signal name Controller User created cable ...

Страница 118: ... 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 Shield DA DB SG FG Signal name D Sub 9 Pin plug Pin Shell Terminal block Signal name Controller User created cable CA4 ADPONL 01 Display RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 Shield DA DB SG FG Shield DA DB SG FG Signal name D Sub 9 Pin plug Pin Shell Terminal block Signal name Controller Terminal block Signal name Controller User created ...

Страница 119: ...r is required Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG FG Terminal block Signal name Controller User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Shield RDA SDA DA DB SG FG Shield DA DB SG FG Terminal block Signal name Controller Terminal block Signal name Controller User created cable ...

Страница 120: ... DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 Shield DA DB SG FG Signal name D Sub 9 Pin socket Pin Shell Terminal block Signal name Controller Display ERB 9 CSB 6 NC 3 DATA 2 GND SG 5 NC 7 ERA 4 CSA 8 FG DATA 1 Shield DA DB SG FG Shield DA DB SG FG Signal name D Sub 9 Pin socket Pin Shell Terminal block Signal name Controller Terminal block Signal name Controller Display ERB 9 CSB 6 ...

Страница 121: ... resistor is required SDA RDB SG ERA SDB ERB CSB RDA CSA Shield DA DB SG FG Signal name Terminal block Signal name Controller Display Display side Terminal block SDA RDB SG ERA SDB ERB CSB RDA CSA Shield DA DB SG FG Shield DA DB SG FG Signal name Terminal block Signal name Controller Terminal block Signal name Controller Display Display side Terminal block ...

Страница 122: ...tor is required In COM on the GP 4107 the SG and FG terminals are isolated Shield DA DB SG FG Terminal block Signal name Controller Display Pin Signal name NC NC GND SG RS RTS 5V NC NC FG LINE LINE 3 8 1 2 5 4 6 7 9 Shell Display side D Sub 9pin plug Shield DA DB SG FG Shield DA DB SG FG Terminal block Signal name Controller Terminal block Signal name Controller Display Pin Signal name NC NC GND S...

Страница 123: ...wire IPC COM Port page 7 7A COM port conversion adapter by Pro face CA3 ADPCOM 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable Cable length 500m or less 7B User created cable GP3000 4 COM2 4 All GP3000 models except the GP 3200 Series and AGP 3302B 7C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADP...

Страница 124: ...munication connection RDA SDA Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 User created cable Signal name RDB SDB SG FG CA3 ADPCOM 01 CA3 ADPTRM 01 Display Terminal block Shield Connector for the host side communication connection RDA SDA Shield Connector for the host side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Signal name RDB SDB SG RDA SDA Pin 14 12 15 13...

Страница 125: ...ector for the host side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 D Sub 9 pin socket Pin Shell Display Shield Connector for the host side communication connection Shield Connector for the host side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Signal name RDB SDB SG RDA...

Страница 126: ...munication connection RDA SDA Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 User created cable Signal name RDB SDB SG FG CA4 ADPONL 01 CA3 ADPTRM 01 Display Terminal block Shield Connector for the host side communication connection RDA SDA Shield Connector for the host side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Signal name RDB SDB SG RDA SDA Pin 14 12 15 13...

Страница 127: ...side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 User created cable CA4 ADPONL 01 Display Signal name RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 D Sub 9 pin plug Pin Shell Shield Connector for the host side communication connection Shield Connector for the host side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Signal name RDB SDB ...

Страница 128: ...unication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Display side Terminal block Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Display Shield Connector for the host side communication connection Shield Connector for the host side communication connection Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Signal name RDB SDB SG RDA SDA Pin 14 12 15 13 11 Display side Terminal bloc...

Страница 129: ...r less 8B User created cable GP3000 3 COM2 3 All GP3000 models except the GP 3200 Series and AGP 3302B 8C Online adapter by Pro face CA4 ADPONL 01 Connector terminal block conversion adapter by Pro face CA3 ADPTRM 01 User created cable 8D Online adapter by Pro face CA4 ADPONL 01 User created cable IPC 4 4 Available only with COM ports that support RS 422 485 2wire IPC COM Port page 7 8E COM port c...

Страница 130: ...DA Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Terminal block Shield Terminal block Controller RDA SDA Signal name DA DB SG Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than...

Страница 131: ...name DA DB SG Display Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Signal name SDA 3 RDB 2 SG 5 4 ERA SDB ERB 7 9 CSB 6 FG RDA 1 CSA 8 D Sub 9 pin socket Pin Shell Shield Terminal block Controller Signal name DA DB SG Display Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 ...

Страница 132: ...DA Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W User created cable Signal name RDB SDB SG TERM CA4 ADPONL 01 CA3 ADPTRM 01 Display Terminal block Shield Terminal block Controller RDA SDA Signal name DA DB SG Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than...

Страница 133: ...er Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W User created cable CA4 ADPONL 01 Display Signal name RDB 7 RDA 2 SDB 8 9 TERMTX SDA FG 3 TERMRX 1 SG 5 D Sub 9 pin plug Pin Shell Shield Terminal block Controller Signal name DA DB SG Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal res...

Страница 134: ...DA Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W User created cable Signal name RDB SDB SG TERM CA3 ADPCOM 01 CA3 ADPTRM 01 Display Terminal block Shield Terminal block Controller RDA SDA Signal name DA DB SG Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than...

Страница 135: ...ck Controller Signal name DA DB SG Display Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Signal name NC 3 DATA 2 GND SG 5 4 ERA NC ERB 7 9 CSB 6 FG DATA 1 CSA 8 D Sub 9 pin socket Pin Shell Shield Terminal block Controller Signal name DA DB SG Display Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resis...

Страница 136: ...Value 1 OFF 2 OFF 3 ON 4 ON Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Shield Terminal block Controller Signal name DA DB SG Display Terminal resistance 1 Terminal resistance 150Ω 5 more than 1 2W Display side Terminal block Signal name SDA RDB SG ERA SDB ERB CSB RDA CSA Shield Terminal block Controller Signal name DA DB SG Display Shield Terminal block Controller Signal name DA DB SG Terminal...

Страница 137: ...name DA DB SG Display Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω 5 more than 1 2W Pin Signal name NC NC GND SG RS RTS 5V NC NC FG LINE LINE 3 8 1 2 5 4 6 7 9 Shell Display side D Sub 9pin plug Shield Terminal block Controller Signal name DA DB SG Display Shield Terminal block Controller Signal name DA DB SG Terminal resistance 150Ω 5 more than 1 2W Terminal resistance 150Ω ...

Страница 138: ...ing word address from the External Device sets particular bits of that word address to ON and then returns the resulting address to the External Device Note that the correct data may not be written if you change the word address using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may c...

Страница 139: ... the word address using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX R...

Страница 140: ...ddress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Ma...

Страница 141: ... address using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference ...

Страница 142: ...dress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Man...

Страница 143: ...dress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Man...

Страница 144: ...dress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Man...

Страница 145: ...ress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Manu...

Страница 146: ...dress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Man...

Страница 147: ...word address using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Refere...

Страница 148: ... address using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference ...

Страница 149: ...ddress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Ma...

Страница 150: ...ddress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Ma...

Страница 151: ...ddress using the ladder program while the Display reads data from the External Device and returns it Setting Enable System Data Area in the system area setting of GP Pro EX may cause malfunction Do not set Enable System Data Area You can set only the reading area size in the Controller s system area setting Refer to the GP Pro EX Reference Manual for the reading area size Cf GP Pro EX Reference Ma...

Страница 152: ... 3 SDC20 SDC21 7 4 SDC30 SDC31 7 5 SDC40A 7 6 SDC40B Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word ...

Страница 153: ...0 Word Address Device Device Name Device Code HEX Address Code Data 000 0080 Word Address Data 001 0081 Word Address Data 002 0082 Word Address Data 021 00A1 Word Address Data 022 00A2 Word Address Data 023 00A3 Word Address Data 041 00C1 Word Address Data 045 00C5 Word Address Data 061 00E1 Word Address Data 071 00F1 Word Address Data 074 00F4 Word Address Data 0A1 0121 Word Address Data 0A2 0122...

Страница 154: ...F2 0172 Word Address Data 0F3 0173 Word Address Data 103 0183 Word Address Data 201 0281 Word Address Data 202 0282 Word Address Data 203 0283 Word Address Data 211 0291 Word Address Data 212 0292 Word Address Data 213 0293 Word Address Data 214 0294 Word Address Data 234 02B4 Word Address Data 235 02B5 Word Address Data 236 02B6 Word Address Data 241 02C1 Word Address Data 242 02C2 Word Address D...

Страница 155: ...2 0CE2 0CE3 Word Address Data CF1 0D71 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code Data 0080 Word Address Device Device Name Device Code HEX Address Code ...

Страница 156: ...first one or use the random monitor Item Description No Error No Device Name Name of the External Device where an error has occurred Device name is the title of the External Device set with GP Pro EX Initial value PLC1 Error Message Displays messages related to an error that has occurred Error Occurrence Area Displays the IP address or device address of the External Device where an error has occur...

Отзывы: