8-59
8
NOTICE
ECB00932
To charge a VRLA (Valve Regulated Lead
Acid) battery, a special (constant-voltage)
battery charger is required. Using a con-
ventional battery charger will damage the
battery.
To store the battery
If the vehicle will not be used for more than
one month, remove the battery, fully charge
it, and then place it in a cool, dry place.
If the battery will be stored for more than
two months, check it at least once a month
and fully charge it if necessary.
NOTICE
ECB00941
Always keep the battery charged. Storing
a discharged battery can cause perma-
nent battery damage.
To install the battery
TIP
Be sure the battery is fully charged.
1. Place the battery in its compartment.
2. Connect the positive battery lead first,
then the negative battery lead by install-
ing their bolt.
NOTICE:
When installing
the battery, the main switch must be
off, and the positive lead must be con-
nected before the negative lead.
[ECB01111]
1. Positive battery lead (red)
2. Negative battery lead (black)
3. Battery
1
2
3
UB5712E0.book Page 59 Friday, October 21, 2016 10:19 AM