AUTO SETUP (IntelliBeam)
35
En
SETUP
English
■
Error messages for AUTO SETUP
Before the AUTO SETUP procedure starts
While the AUTO SETUP procedure is in progress
If one of the errors shown below except E-1 is displayed, press RETURN. In case you have started the AUTO SETUP
procedure by pressing AUTO SETUP on the remote control in
step
3, run the procedure again from
3 after once the
screen disappears. In case you have started the AUTO SETUP procedure by pressing MENU on the remote control in
step
3, run the procedure again from
5 after the screen in
step
4 is displayed. Run the MANUAL SETUP if the problem is
difficult to be saved.
Error message
Cause
Remedy
See
page
ERROR E-2
No MIC Detected. Please check
MIC connection and re-try.
The optimizer microphone is not
connected to this unit.
Connect the optimizer microphone to
this unit.
Error message
Cause
Remedy
See
page
ERROR E-1
Please test in quieter environment.
There is too much unwanted noise in
your listening room.
Make sure that your listening room is as
quiet as possible. You may want to
choose certain hours during the day
when there is not much noise coming
from outside.
—
ERROR E-2
No MIC detected. Please check
MIC connection and re-try.
The optimizer microphone was
disconnected while the AUTO SETUP
procedure was in progress.
Make sure that the optimizer microphone
is firmly connected to this unit.
ERROR E-3
Unexpected control is detected.
Please re-try.
Some other operations were performed
on this unit while the AUTO SETUP
procedure was in progress.
Do not perform any other operations
while the AUTO SETUP procedure is in
progress.
—
ERROR E-4
Please check MIC position. MIC
should be set in front of YSP.
The optimizer microphone is not placed
in front of this unit.
Make sure that the optimizer microphone
is installed in front of this unit.
ERROR E-5
Please check MIC position. MIC
should be set above 1.8m/6ft.
The optimizer microphone is not placed
in the right distance from this unit.
Make sure that the optimizer microphone
is installed more than 1.8 m from the
front of this unit and within 1 m from the
center height of this unit.
ERROR E-6
Volume level is lower than
expected. Please check MIC
position/connection and re-try.
The optimizer microphone cannot collect
the sound produced by this unit because
the sound output level is too low.
Make sure that the optimizer microphone
is firmly connected to this unit and
placed in a proper location. If the
problem persists, contact the nearest
YAMAHA service center for assistance.
ERROR E-7
Unexpected error happened.
Please re-try.
An internal system error occurred.
Repeat the AUTO SETUP procedure.
—