MAINTENANCE
1
2
3
4
5
6
7
8
9
10
11
8-4
JW2
G
Before charging:
only add distilled
water if fluid is below the top of the
plates, and then add just enough to
cover plates.
G
After charging:
open the vent caps
and look inside the fill wells. Add
distilled water until the electrolyte
level is 1/8" below the bottom of the
fill well. A piece of rubber can be
used safely as a dipstick to help
determine this level. Clean, replace
and tighten all vent caps.
Normal tap water contains
minerals which are harmful to a
battery; therefore, refill only with
distilled water.
3. Using a hydrometer, check the
specific gravity of the battery fluid
in each cell against the readings
on the chart below. Consult a
Yamaha dealer if any low readings
are found, or if readings vary more
than one point between cells.
Temperature
Satisfactory Uncorrected
˚F
˚C
Hydrometer Reading
120
48.9
1.244
110
43.3
1.248
100
37.8
1.252
90
32.2
1.256
80
26.7
1.260
70
21.1
1.264
60
15.6
1.268
50
10.0
1.272
40
4.4
1.276
30
-1.1
1.280
Y-936
PO
S
NEG
1/8”
Electrolyte 1/8” Below
Bottom of Fill Well
Max. Level -
discharged battery
Max. Level -
charged battery
Fill Well
Electrolyte
Y-937