Perio
d
ic maintenance an
d
a
d
justment
6-31
6
2. If the battery will be stored for
more than two months, check it at
least once a month and fully
charge it if necessary.
3. Fully charge the battery before in-
stallation.
NOTICE:
When install-
in
g
the
b
attery,
b
e sure the key
is turne
d
to “OFF”, then connect
the positive lea
d
b
efore con-
nectin
g
the ne
g
ative lea
d
.
[ECA16841]
4. When installing the battery, make
sure the positive battery lead is
routed through the hole in the bat-
tery band and that both battery
leads are properly connected to
the battery terminals.
NOTICE
ECA16531
Always keep the
b
attery char
g
e
d
.
Storin
g
a
d
ischar
g
e
d
b
attery can
cause permanent
b
attery
d
ama
g
e.
5. Place the battery cover in the orig-
inal position, and then install the
bolts.
6. Install the diagnostic connector by
pushing it downward.
7. Install the seat holder by installing
the bolts, and then tighten the
bolts to the specified torque.
EAUM3670
Replacin
g
the fuses
The main fuse and the fuse boxes are
located under the seat.
To access the fuses
1. Remove the seat. (See page 3-19.)
2. Remove the seat holder by remov-
ing the bolts.
3. Remove the diagnostic connector
by pulling it upward.
4. Remove the battery cover by re-
moving the bolts.
Ti
g
htenin
g
torque:
Seat holder bolts:
7 Nm (0.7 m·kgf, 5.1 ft·lbf)
1. Holder
2. Bolt
ZAUM1377
2
1
UB34E0E0.book Page 31 Friday, July 10, 2015 10:31 AM