Explanation of Graphical Symbols

 

The lightning flash with arrowhead symbol 
within an equilateral triangle is intended to alert 
the user to the presence of uninsulated 
“dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the product.

 

IMPORTANT SAFETY INSTRUCTIONS

 

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8

Do not install near any heat sources such as radiators, 
heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If 
the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10

Protect the power cord from being walked on or pinched 
particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus.

11

Only use attachments/accessories specified by the 
manufacturer.

12

Use only with the cart, stand, 
tripod, bracket, or table specified 
by the manufacturer, or sold with 
the apparatus. When a cart is 
used, use caution when moving 
the cart/apparatus combination 
to avoid injury from tip-over.

13

Unplug this apparatus during 
lightning storms or when unused for long periods of 
time.

14

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been spilled or objects have 
fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, 
or has been dropped.

 

(98-6500)

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER (OR BACK). NO USER-SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

WARNING

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

 

FCC INFORMATION (U.S.A.)

 

1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!

 

This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not 
expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.

 

2. IMPORTANT:

 

 When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s 

supplied with this product MUST be used. Follow all installation instructions. Failure to follow instructions could void your FCC authori-
zation to use this product in the USA.

 

* This applies only to products (XP7000, XP5000) distributed by YAMAHA CORPORATION OF AMERICA.

(oscillator)

Содержание XP7000

Страница 1: ...POWER AMPLIFIER OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE INSTRUCCIONES ES FR DE EN English Deutsch Fran ais Espa ol...

Страница 2: ...oint where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold...

Страница 3: ...ving the device remove all connected cables When setting up the product make sure that the AC outlet you are using is easily accessible If some trouble or malfunction occurs immediately turn off the p...

Страница 4: ...onents Illustrations in this manual are for explanatory purposes only and may not match the actual appearance of the product during operation Company names and product names used in this Owner s Manua...

Страница 5: ...tep Volume control are provided for each channel A PROTECTION indicator that shows the state of various protection systems power on off detection output protection DC detection a TEMP indicator that i...

Страница 6: ...turn off the amplifier and allow it time to cool down See the Pre cautions section of this Owner s Manual for ways to prevent the amplifier from overheating 4 CLIP indicator Lights up red when the ou...

Страница 7: ...itch STEREO mode In STEREO mode channels A and B are completely independent PARALLEL mode In PARALLEL mode the channel A input signal is sent both to the channel A power amp and the channel B power am...

Страница 8: ...The volume controls on the front panel A and B let you control the volume of each channel independently 5 way binding post Speakon connector Parallel Mode Set the Mode switch to PARALLEL to use the u...

Страница 9: ...the unit as a high power mono amplifier The volume control A on the front panel A lets you control the volume 5 way binding post Speakon connector Note In this case the loads for A and B are directly...

Страница 10: ...kers at 15 W for 315 W The total is 625 W per channel Be sure to use speakers that support the XP7000 s line out voltage of 70 V The XP3500 enables you to connect in bridge fashion multiple high imped...

Страница 11: ...eaker terminals Tighten the terminals to securely clamp the wires Refer to page 8 for speaker polarities Be sure that the bare wire ends do not jut out from the terminals and touch the chassis 4 Reatt...

Страница 12: ...around the amplifier The TEMP indicator lights up to indicate tem perature warning PROTECTION indica tor lights The heat sink temperature has exceeded 90 C 194 F Check the amplifier ventilation condi...

Страница 13: ...390 W 4 STEREO 590 W 590 W 590 W 590 W 590 W 590 W 8 BRIDGED 1180 W 1180 W 1180 W 20 20 kHz THD N 0 1 8 STEREO 350 W 350 W 350 W 350 W 350 W 350 W 4 STEREO 450 W 450 W 435 W 435 W 450 W 450 W 8 BRIDGE...

Страница 14: ...26 dB position 13 7 dBu 120V 240V 13 6 dBu 230V 12 2 dBu 10 7 dBu 9 2 dBu 5 2 dBu 32 dB position 7 7 dBu 120V 240V 7 6 dBu 230V 6 2 dBu 4 7 dBu 3 2 dBu 0 8 dBu Maximum Input Voltage MIN 22 dBu Input...

Страница 15: ...to GND 4 REMOTE CONTROL NC 5 NC 6 MUTE CH B MUTE On Control Connect the pin to GND max 1mA flows MUTE Off Control Open the pin 5V applied 7 MUTE CH A 8 MONITOR NC 9 NC 10 PROTECTION MUTE STATUS CH B P...

Страница 16: ...CTION SIGNAL CLIP LIMIT RE GR GR RE RE BSIG TEMPERATURE SENSOR TEMPERATURE SENSOR PROTECTION CIRCUIT FAN CONTROL CIRCUIT POWER ON DETECT CIRCUIT LIMITER LIMITER PA 5V 5 B 15 15 B 24 24 15V 15V 15V U A...

Страница 17: ...CIRCUIT CH B TEMP PROTECTION SIGNAL CLIP LIMIT RE GR GR RE RE SP RELAY BSIG TEMPERATURE SENSOR LED DRIVE CIRCUIT FAN CONTROL CIRCUIT PROTECTION CIRCUIT LIMITER LIMITER PA 24 24 B B 15 15 15V Thermal...

Страница 18: ...0V 230 240V In Out Dissipated Btu h kcal h standby 0 08 0 04 5 0 5 17 4 idle 1 0 0 5 35 0 35 119 30 1 8 power 8 ch 4 0 2 2 277 131 146 499 126 4 ch 6 2 3 4 436 188 249 848 214 1 3 power 8 ch 9 3 5 1 6...

Страница 19: ...XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual 19 Memo...

Страница 20: ...20 XP7000 XP5000 XP3500 XP2500 XP1000 Owner s Manual Memo...

Страница 21: ......

Страница 22: ...S G Pro Audio Division 2005 Yamaha Corporation 305POAPx x 01E0 Printed in Vietnam WF37200 Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manua...

Отзывы: