Usin
g
and connectin
g
the [REMOTE] connector and [FAULT OUTPUT] connector
XMV4280/XMV4140 Owner’s Manual
19
You must use the supplied Euroblock plugs when making con-
nections to the [REMOTE] connector or [FAULT OUTPUT]
connector.
If these have been lost, please contact your Yamaha dealer.
1. Loosen terminal screws.
2. Insert cables.
3. Securely ti
g
hten terminal screws.
Pull the cables (not too strongly) to confirm that they are
securely connected.
4. Insert the Euroblock plu
g
into the [REMOTE]
connector or [FAULT OUTPUT] connector of
the device.
Connecting the [REMOTE] connector
or [FAULT OUTPUT] connector
Cable preparation
• To prepare the cable for attachment to a Euroblock
connector, strip the wire as shown in the illustration
using stranded wire to make connections. With a Euro-
block connection, stranded wires may be prone to
breakage because of metal fatigue due to the weight of
the cable or due to vibration.
• If cables will be frequently connected and discon-
nected, as in the case of a portable installation, we
recommend that you use ferrules with insulation
sleeves. Use a ferrule whose conductor portion has an
external diameter of 1.3 mm or less, and a length of
approximately 5 mm (such as the AI0,5-6WH made by
the Phoenix Contact corporation).
NOTE
A slotted screwdriver with a blade width of about 3 millime-
ters is recommended.
approx.
5 mm
NOTE
Do not tin (plate with solder) the exposed end.
1.3 mm or less
approx.
5 mm
Loosen.
Terminal
screw
Slotted screwdriver
Euroblock plug
3 mm or less
Содержание XMV4280
Страница 27: ...XMV4280 XMV4140 Owner s Manual 27 MEMO ...