background image

5

Rear Panel

1

HPF switches
These switches are used to turn on and off the HPF
(High Pass Filter) for each channel. When set to ON,
frequencies below 80 Hz are filtered using a 12 dB/
octave high pass filter.
Turn this switch ON if 70V-line, high-impedance
speakers are connected.

In Bridge mode, only the HPF switch of the first
channel in the pair is active, i.e., channel A of pair A–
B, channel C of pair C–D, and channel E of pair E–F
(XM6150 only).

2

Attenuators
These detented controls are used to attenuate the input
signal from –

 dB to 0 dB for each channel.

In Bridge mode, only the attenuator of the first channel
in the pair is active, i.e., channel A of pair A–B,
channel C of pair C–D, and channel E of pair E–F
(XM6150 only).

3

XLR inputs
These balanced XLR-3-31 type connectors are used to
connect input signals. They are wired pin 1–ground,
pin 2–hot (+), and pin 3–cold (–).

1

2

3

Cold

Ground

Hot

In Bridge mode, only the XLR input of the first channel
in the pair is active, i.e., channel A of pair A–B,
channel C of pair C–D, and channel E of pair E–F
(XM6150 only).

80

1

3

4

8

7

5

2

6

4

Euroblock connectors
These balanced Euroblock connectors are used to
connect input signals.

In Bridge mode, only the Euroblock connector of the
first channel in the pair is active, i.e., channel A of pair
A–B, channel C of pair C–D, and channel E of pair E–
F (XM6150 only).

5

CH A TO ALL CH switch
This switch is used to feed the input signal connected
to channel A to all channels.

When set to EACH CH, the input signal connected to
each channel is amplified and output by each channel
respectively. When set to CH A TO ALL CH,
however, the input signal connected to channel A is
fed to all channels.

6

BRIDGE switches
These switches are used to bridge the following
channel pairs: A–B, C–D, and E–F (XM6150 only).

When set to OFF, the two channels operate indepen-
dently. For example, the signal connected to input
channel A is amplified and output by the channel A
outputs, while the signal connected to input channel B
is amplified and output by the channel B outputs.
When set to BRIDGE, the signal connected to input
channel A is amplified and output by the bridged
outputs A–B, and channel B’s inputs are not used.

* The illustration shows model XM6150.

Содержание XM6150

Страница 1: ...POWER AMPLIFIER XM6150 XM4220 Owner s Manual E...

Страница 2: ...ow noise cooling fan system ensures high reliability even under the most demanding conditions This Owner s Manual applies to the XM6150 6CH and XM4220 4CH power amplifier In order to take full advanta...

Страница 3: ...for a replacement Using the unit with a damaged power cord is a fire and electrical shock hazard Do not remove the unit s cover You could receive an electrical shock If you think internal inspection...

Страница 4: ...tes if a DC voltage is detected at the amplifier s outputs Once the DC voltage problem is corrected the protection system deactivates automatically and the amplifier is ready for normal operation If t...

Страница 5: ...r C D and channel E of pair E F XM6150 only 80 1 3 4 8 7 5 2 6 4 Euroblock connectors These balanced Euroblock connectors are used to connect input signals In Bridge mode only the Euroblock connector...

Страница 6: ...e operation Normal mode Bridge mode Speaker min 8 Speaker min 4 Speaker min 4 In Bridge mode you can connect multiple high impedance speakers that are compatible with 70V line output in parallel The n...

Страница 7: ...the cover attachment screws and remove the protective cover from the speaker terminals Screw 3 After removing approx 15 mm of insulation from the ends of the speaker cables pass the bare ends of the s...

Страница 8: ...10 cm or more between the rear panel of the rack and the rear panel of the amplifier Fan Use a fan with 1 5 m3 min or more maximum wind and 5 mmH2 O or more maximum static pressure Mounting Install th...

Страница 9: ...ed 15 k Unbalanced Controls Front Panel POWER switch ON OFF Rear Panel Volume 31 position ch BRIDGE switch ON OFF 2ch HPFswitch ON OFF ch fc 80 Hz 12 dB oct CH A TO ALL CH switch Connectors Input XLR...

Страница 10: ...10 Block Diagram Note The block diagram indicated in the dotted frame applies only to model XM6150...

Страница 11: ...11 Dimensions Unit mm D 319 W 480 H 132...

Страница 12: ...mpedance of the connected speaker is too low The heat sink temperature has exceeded 90 C A DC voltage of 2 V or greater was detected in the amplifier s output circuit Locate and remove the short Check...

Страница 13: ...YAMAHA CORPORATION V455890 R0 1 AP 16 Pro Audio Division 18 3 P O Box 3 Hamamatsu 430 8651 Japan NP Printed in Taiwan...

Отзывы: