4-2
E
1. Put the watercraft on land in a horizontal
position.
2. Open the flushing hose connector
cap
1
, and then insert the garden hose
adapter
2
into the flushing hose con-
nector
3
and turn it until it is securely
connected.
3. Connect the garden hose adapter to a
water tap using a hose.
4. Start the engine, and then immediately
turn the water supply on until water flows
out continually from the cooling water
pilot outlet.
5. Run the engine at idling speed for about
3 minutes watching the engine condition.
If the engine stops while flushing, turn
the water supply off immediately and
repeat the above steps.
6. Turn the water supply off, and then force
the remaining water out from the cooling
passages by running the engine at
4,000 r/min or less within 10 to 15 sec-
onds.
7. Stop the engine.
8. Remove the garden hose adapter and
secure the cap.
UF0V14.book Page 2 Thursday, July 8, 2004 11:35 AM
Содержание XLT1200 WaveRunner 2005
Страница 1: ...2005 WaveRunner XLT1200 OWNER S OPERATOR S MANUAL ...
Страница 2: ......
Страница 8: ...1 3 E EJU00998 Important labels EJU01351 Label location ...
Страница 9: ...1 4 E EJU01352 Warning labels 1 2 3 4 ...
Страница 10: ...1 5 E EJU01354 Other labels 7 8 5 6 9 0 ...
Страница 11: ...1 6 E A B D E C F ...
Страница 129: ...E 6 EJU01124 APPENDIX Limited warranty 6 1 YAMAHA EXTENDED SERVICE Y E S 6 3 Index 6 4 ...
Страница 136: ......