3-42
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
NOTE:
CAUTION:
NOTE:
Since MF batteries are sealed, it is not possible
to check the charge state of the battery by mea-
suring the specific gravity of the electrolyte.
Therefore, the charge of the battery has to be
checked by measuring the voltage at the battery
terminals.
1. Remove:
S
seat
2. Disconnect:
S
battery leads
(from the battery terminals)
First, disconnect the negative lead
1
, then
the positive lead
2
.
3. Remove:
S
battery
4. Check:
S
battery charge
a. Connect a pocket tester to the battery termi-
nals.
Tester positive lead
battery positive
terminal
Tester negative lead
battery negative
terminal
S
The charge state of a MF battery can be
checked by measuring its open-circuit voltage
(i.e., the voltage when the positive terminal is
disconnected).
S
No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown in
the charts and the following example.
Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20
30 %
5. Charge:
S
battery
(refer to the appropriate charging method il-
lustration)
Содержание XJR1300 (L) '99
Страница 1: ......
Страница 2: ......
Страница 8: ......
Страница 10: ...GEN INFO ...
Страница 18: ...GEN INFO ...
Страница 20: ...SPEC ...
Страница 32: ...2 12 SPEC MAINTENANCE SPECIFICATIONS Tightening sequence Cylinder head Crankcase ...
Страница 45: ...2 25 1 Camshaft 2 Crankshaft 3 Oil pump 4 Oil filter SPEC LUBRICATION DIAGRAMS ...
Страница 56: ...SPEC ...
Страница 108: ...CHK ADJ ...
Страница 112: ...ENG ...
Страница 202: ...CARB ...
Страница 282: ...CHAS ...
Страница 284: ...ELEC ...
Страница 306: ...7 22 CHARGING SYSTEM ELEC 1 2 3 5 Generator Main fuse Battery Main switch EB804000 CHARGING SYSTEM CIRCUIT DIAGRAM ...
Страница 330: ...TRBL SHTG ...
Страница 336: ...TRBL SHTG ...