64
E
–
+
ELEC
INDICATION SYSTEM
Compass display
(for FX Cruiser High Output)
1. Check:
• Compass display
Incorrect reading
→
Replace the com-
pass sensor.
Air temperature display
(for FX Cruiser High Output)
1. Check:
• Air temperature display
Incorrect reading
→
Replace the com-
pass sensor.
Checking steps:
• Using a compass for reference, point the
watercraft north.
• Turn on the multifunction meter and
check that “NORTH” appears on the
meter.
• If “NORTH” does not appear on the multi-
function meter, replace the compass sen-
sor.
NOTE:
Be sure to check the compass display again
after replacing the compass sensor. If the
compass display is still incorrect, replace
the multifunction meter.
Checking steps:
• Measure the ambient air temperature.
• Turn on the multifunction meter and
check the air temperature displayed on
the meter.
• If the air temperature displayed on the
multifunction meter is more than
±
5 °C
(9 °F) different from the ambient air tem-
perature, replace the compass sensor.
NOTE:
Be sure to check the air temperature dis-
play again after replacing the compass sen-
sor. If the air temperature display is still
incorrect, replace the multifunction meter.
N