Indication system
Multifunction meter
1. Check:
•
Multifunction meter external appearance
Cracked meter housing/meter is fogged/
shows signs of water intrusion
→
Replace the multifunction meter.
2. Check:
•
Multifunction meter display
Intermittent or missing segment
a
→
Replace the multifunction meter.
No display
→
Measure the multifunction
meter input voltage.
Checking step:
1. Push the unlock button, and then check
that all indicator lights and display ele-
ments on the multifunction meter light up.
1
Indicator lights
2
Left multifunction display
3
Analog speedometer/tachometer
4
Right multifunction display (FX Cruiser SHO)
NOTE:
When pushing the unlock button, the analog
speedometer/tachometer makes 1 sweep, all
displays light up for 2 seconds, and then it
starts to operate normally.
1
1
2
3
4
a
Содержание WaveRunner FX Cruiser SHO
Страница 1: ...SERVICE MANUAL FX SHO WaveRunner F1W 28197 1K 11 FX Cruiser SHO LIT 18616 03 12 LIT186160312 ...
Страница 58: ...1 53 E GEN INFO MEMO Technical tips ...
Страница 82: ...2 23 E SPEC MEMO Cable and hose routing ...
Страница 110: ...3 27 E CHK ADJ MEMO General ...
Страница 243: ...5 118 E POWR 1 2 3 4 5 6 7 8 9 MEMO Cooling water ...
Страница 275: ...6 30 E JET PUMP 1 2 3 4 5 6 7 8 9 MEMO Intermediate housing ...
Страница 353: ...E ELEC 1 2 3 4 5 6 7 8 9 7 76 MEMO Indication system ...
Страница 410: ...8 55 E HULL HOOD MEMO Deck and hull ...
Страница 429: ...9 18 E TRBL ANLS 1 2 3 4 5 6 7 8 9 MEMO Engine unit trouble analysis ...
Страница 431: ......
Страница 432: ...YAMAHA MOTOR CORPORATION USA Printed in USA Jan 2008 0 0 1 CR E ...