Yamaha TX6n Скачать руководство пользователя страница 2

 

TX6n/5n/4n  Owner’s Manual

 

2

 

The above warning is located on the top of the unit.

 

Explanation of Graphical Symbols

 

The lightning flash with arrowhead symbol 
within an equilateral triangle is intended to 
alert the user to the presence of uninsulated 
“dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude 
to constitute a risk of electric shock to 
persons.

The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and 
maintenance (servicing) instructions in the 
literature accompanying the product.

 

IMPORTANT SAFETY INSTRUCTIONS

 

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8

Do not install near any heat sources such as 
radiators, heat registers, stoves, or other apparatus 
(including amplifiers) that produce heat.

9

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong are provided for your safety. If 
the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10

Protect the power cord from being walked on or 
pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the 
apparatus.

11

Only use attachments/accessories specified by the 
manufacturer.

12

Use only with the cart, stand, 
tripod, bracket, or table 
specified by the manufacturer, 
or sold with the apparatus. 
When a cart is used, use 
caution when moving the cart/
apparatus combination to 
avoid injury from tip-over.

13

Unplug this apparatus during lightning storms or 
when unused for long periods of time.

14

Refer all servicing to qualified service personnel. 
Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

 

(UL60065_03)

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER (OR BACK). NO USER-SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

C A U T I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

WARNING

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR 
MOISTURE.

Содержание TX6n

Страница 1: ...IT RU ES FR DE EN...

Страница 2: ...two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the o...

Страница 3: ...it in as small chemical waste lithium disposal 1 IMPORTANT NOTICE DO NOT MODIFY THIS UNIT This product when installed as indicated in the instructions contained in this manual meets FCC requirements M...

Страница 4: ...that the AC outlet you are using is easily accessible If some trouble or malfunction occurs immediately turn off the power switch and disconnect the plug from the outlet Even when the power switch is...

Страница 5: ...ed in memory that does not require backup power and will be retained even if the backup battery fails Always turn the power off when the device is not in use The performance of components with moving...

Страница 6: ...you are mounting this device along with other types of device in an EIA standard rack the ambient temperature inside the rack may rise due to heat produced from the other devices prevent ing this dev...

Страница 7: ...e can be controlled from the panel of the TXn unit or via Amp Editor Speaker processor libraries created on the Yamaha DME series or the SP2060 can also be used About Setup Attaching the handles You c...

Страница 8: ...ng to set up the TXn so that at startup it will recall the scene number selected before you turned off the power to the device Do not turn off the power while the upper part of the display indicates D...

Страница 9: ...lay shows the attenuator i e in the HOME screen or the METER screen you can use encodersA and B to adjust each channel s attenuation If the display shows a screen other than the HOME screen or METER s...

Страница 10: ...operation lock on off Scene Setup Makes scene settings Misc Setup Sets the amplifier s internal clock etc MENU General Sensitivity Amp Gain Sets the input sensitivity gain Stereo Bridge Parallel Speci...

Страница 11: ...of 5 way binding post connectors and Speakon connectors are internally parallel connected When using both connectors simultaneously total speaker impedance of each connector must be 4 16 The amplifier...

Страница 12: ...to access Stereo Bridge Parallel screen 4 Use the encoder B to select the desired mode and press the ENTER button to confirm Set the amplifier gain 1 Follow the steps 1 and 2 of the above Mode Set tin...

Страница 13: ...Be sure that the bare wire ends do not jut out from the terminals and touch the chassis From above insert the Y plugs all the way into the opening and tighten the terminals Insert the Speakon cable pl...

Страница 14: ...mum length cannot be guaranteed in some cases Since the TXn supports Auto MDI MDI X it will automatically detect whether the connected cable is of the straight type or crossover type and will configur...

Страница 15: ...power sup ply has malfunctioned contact your Yamaha dealer Noise from the speaker The word clock from the slot input is not synchronized with the master clock Select the word clock from the slot as th...

Страница 16: ...Analog input to speaker output Input sensitivity 24dBu 103dB 102dB 101dB AES EBU input to speaker output 108dB 107dB 106dB All Models THD N 1kHz half power RL 4 8 0 2 RL 2 0 4 Intermodulation Distor...

Страница 17: ...3P x 1 Indicators LCD 160 x 64 Full dot type LED POWER x 1 White STANDBY x 1 Orange PARALLEL x 1 Orange BRIDGE x 1 Green PROTECTION x 1 Red NETWORK x 1 Green IDENTIFY x 1 Blue SIGNAL x 1 Green CLIP x...

Страница 18: ...Current Sensing Voltage Limitter Voltage Limitter EEEngine EEEngine ASO Limitter Temperature sensor Temperature sensor B_2 E_2 15 E _ 2 E_2 15 E _ 2 B_2 PGND _ 2 Voltage Sensor Current Sensor Voltage...

Страница 19: ...ATOR ANALOG INPUT DIGITAL INPUT 24 0dBu 11 8dBu TX6n 0dBu TX6n 0dBFS digital max GAIN TX5n Clips TX4n Clips TX6n Clips 43 8dBu GAIN 19 8dB min GAIN 43 8dB max GAIN 32 0dB default ATT 0 0dB ATT dB ATTE...

Страница 20: ...Specifications TX6n 5n 4n Owner s Manual 20 Dimensions 10 429 30 405 415 461 17 41 432 88 480 Unit mm...

Страница 21: ...s ch 26 9 14 8 1828 1133 695 2370 597 4ohms ch 40 4 22 2 2910 1833 1077 3670 926 2ohms ch 44 7 24 5 3216 1833 1383 4720 1190 TX5n standby 0 36 0 20 19 0 19 65 16 idle 1 6 0 9 75 0 75 256 65 1 8 power...

Страница 22: ...ui pourraient advenir lors d un traitement inappropri des d chets Pour plus d informations propos de la collecte et du recyclage des d chets d quipements lectriques et lectroniques veuillez con tacter...

Страница 23: ...61 4000 ITALY Yamaha Musica Italia S P A Combo Division Viale Italia 88 20020 Lainate Milano Italy Tel 02 935 771 SPAIN PORTUGAL Yamaha M sica Ib rica S A Ctra de la Coruna km 17 200 28230 Las Rozas...

Страница 24: ...b site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manual U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2009 Yamaha Corporation WP58530 003POZCx x...

Отзывы: