6-29
PERIODIC MAINTENANCE AND MINOR REPAIR
1
2
3
4
5
6
7
8
9
EC000102
c
C
8
Always keep the battery
charged. Storing a discharged
battery can cause permanent
battery damage.
8
To charge a sealed-type (MF)
battery, a special (constant-
voltage) battery charger is
required. Using a conventional
battery charger will damage
the battery. If you do not have
access to a sealed-type (MF)
battery charger, have a
Yamaha dealer charge your
battery.
EAU01307
Replacing the fuse
The fuse holder is located behind
panel B. (See page 6-6 for panel
removal and installation procedures.)
If the fuse is blown, replace it as fol-
lows.
1. Turn the key to “OFF” and turn
off all electrical circuits.
2. Remove the blown fuse, and
then install a new fuse of the
specified amperage.
1
2
1.
Fuse
2.
Spare fuse
EC000103
c
C
Do not use a fuse of a higher
amperage rating than recommend-
ed to avoid causing extensive
damage to the electrical system
and possibly a fire.
3. Turn the key to “ON” and turn on
the electrical circuits to check if
the devices operate.
4. If the fuse immediately blows
again, have a Yamaha dealer
check the electrical system.
Specified fuse: 15A
4PX-9-26-6(AUS) 7/25/00 5:27 PM Page 30
Содержание TT-R TT250RN
Страница 91: ...4PX 9 26 7 8 9 AUS 7 25 00 5 28 PM Page 14...
Страница 92: ...4PX 9 26 7 8 9 AUS 7 25 00 5 28 PM Page 15...
Страница 93: ...4PX 9 26 7 8 9 AUS 7 25 00 5 28 PM Page 16...