4.2.6 DeviceNet
K81
DeviceNet node
Setting Range
Default
Units
Restart
0 to 63
0
-
Required
Function
Specifies the DeviceNet communication node.
K82
DeviceNet speed
Setting Range
Default
Units
Restart
0 to 2
2
-
Required
Function
Specifies the DeviceNet baud rate.
Settings
Setting Value
Description
0
125Kbps
1
250Kbps
2
500Kbps
c
CAutIoN
the baud rate setting specified here must be the same as the baud rate specified at the master station. A normal
data link cannot be established if the settings are not the same.
4.2.7 EtherNet/IP
K81
Port number
Setting Range
Default
Units
Restart
0 to 65535
0
-
Required
Function
Specifies the port number of the TCP/IP communication. (Presently, this parameter is not used.)
-
IP address
Setting Range
Default
Units
Restart
0.0.0.0 to 255.255.255.255
192.168.0.1
-
Required
Function
Specifies the IP address.
When this parameter is set to "0.0.0.0", the DHCP becomes enabled (automatic IP address assignment).
-
Subnet mask
Setting Range
Default
Units
Restart
0.0.0.0 to 255.255.255.255
255.255.255.0
-
Required
Function
Specifies the subnet mask.
-
Default gateway
Setting Range
Default
Units
Restart
0.0.0.0 to 255.255.255.255
192.168.0.254
-
Required
Function
Specifies the IP address of the default gateway.
When the default gateway is not used, it is not necessary to specify this parameter.
c
CAutIoN
EtherNet/Ip setting parameters are available from controller’s software version ver. 1.10.121 onwards.
the ht1 can change these parameters from software version ver. 1.13 onwards while the tS-Manager can change
them from ver. 1.3.3 onwards.
Содержание TS-P
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......