Ref
erences
Intr
oduction
to the SP2060
Fore
w
o
rd
The Contr
ols
and Connector
s
Netw
ork Settings
P
anel Operation
References
SP2060 Owner’s Manual
45
Status messages
* Do NOT turn off the power to the SP2060 while the unit displays the message “DO NOT TURN OFF!” at the bottom of the display.
Troubleshooting
Message
Meaning
Connecting
Connecting to the network.
Download Success
The program has been successfully updated.
Downloading
Program update in progress. Do NOT turn power off while the unit displays this message.
File Operating
A file operation is in progress during which the computer manipulates scene data. Do NOT turn power off
while the unit displays this message.
Network Setup
Preparing network connection.
Panel Locked
The User Lock function is engaged. The panel controls do not work.
Panel Unlocked
The User Lock function has been disengaged. Panel operation is now possible.
Scene Recalling
Scene recall in progress.
Scene Storing
Scene store in progress. Do NOT turn power off while the unit displays this message.
Cannot Recall
Recalling scenes or libraries is disabled.
Cannot Store
The scene store is disabled.
NO X-OVER
Input channels do not feature the X-Over parameter.
NO LIMITER
Input channels do not feature the Limiter parameter.
Protected
You cannot edit or delete protected scenes.
Panel Protected
If the User Lock function is turned on, you cannot change the parameters by using the panel controls.
NO ROUTING
Input channel SUM does not feature the Routing parameter.
NO LEVEL
Input channel SUM does not feature the Level parameter.
Network Busy
There is too much network traffic. Communication is very slow.
Synchronizing
Data is being received from the computer. Do NOT turn power off while the unit displays this message.
Scene Deleting
Deleting a scene. Do NOT turn power off while the unit displays this message.
Symptom
Possible Causes
Possible Solutions
No communication between the
SP2060 and the DME Designer
application software.
The connection cable is not connected properly.
Make sure that the cable is properly connected.
The computer's Ethernet port is not functioning
properly.
Refer to the DME Designer Installation Guide.
The DME-N Network driver has not been
installed.
Install and set up the DME-N Network driver.
No audio output.
The Mute function is turned on.
Turn off the Mute function (see page 36).
The output level is set too low.
Increase the output level (see page 23).
The parameters cannot be edited.
The User Lock function is turned on.
Turn off the User Lock function (see page 33).
Содержание SP2060