5.
Calibration
Mode
■
Key
sensor
measurement
[Start
‐
up]
Panel
button
[REC]
+
[STOP]
+
POWER
ON
[Supplementary
explanation]
Aging
Warming
‐
up
the
luminosity
of
key
sensor
LED
to
be
stabilized
after
the
system
is
switched
ON.
The
number
assigned
to
each
key
corresponding
with
it's
MIDI
NOTE
number.
Keyboard
number
indicated
on
the
display
is
the
actual
key
number
+
20.
Example;
"32"
on
display
means
Key
#12G#
REST
The
keyboard
is
not
pressed.
END
The
keyboard
is
fully
pressed.
[Key
sensor
measurement
procedure]
Before
starting
‐
up
the
measerment
mode
confirm
that
all
keys
are
in
the
rest
position.
All
‐
key
measurement
mode
№
Start
‐
up
Status
Procedure
Buzzer
sound
Display
Mode
Methods
Operation
Term
Explanation
*
Keyboard
No.
All
‐
key
measurement
1
‐
key
measurement Panel
button
[REC]
+
[QUIET]
+
POWER
ON
(Grand
Piano)
[REC]
+
[PIANO]
+
POWER
ON
(Upright
Piano)
Refer
to
"Start
‐
up"
1
Aging
Wait
for
about
30
sec
to
2
min
"AGI"
is
indicated
and
DP(.)
blinks
on
the
display
while
aging.
It
will
proceed
to
step
2
automatically
after
aging
is
terminated.
*
Do
not
touch
the
keys
during
aging.
If
a
key
is
moved,
turn
the
power
OFF
and
re
‐
start
in
the
All
‐
key
measurement
mode.
Lightly
press
each
of
the
88
keys
one
by
one
to
the
end
position.
Depress
the
damper
pedal
or
push
the
[PLAY]
button
once
to
the
register
rest
value,
then
proceed
to
step
4.
*
Pressing
the
same
key
more
than
once
has
no
effect
on
measurement.
3/sec
intermittent
tone
Confirm
all
keys
are
in
the
rest
position.
Depress
the
damper
pedal
or
push
the
[PLAY]
button
once
to
register
the
rest
value,
then
proceed
to
step
3.
*
If
the
key
is
in
the
wrong
position,
correct
to
the
rest
position,
turn
the
power
OFF
and
re
‐
start
in
the
All
‐
key
measurement
mode.
2/sec
intermittent
tone
3
End
value
registration
2
Rest
value
registration
Upright
Piano
Grand
Piano
Calibration
mode
is
a
program
for
adjusting
the
key
sensor
and
damper
pedal
sensor
to
the
optimum
conditions.
Please
confirm
that
the
Keyboard
adjustment
and
Pedal
adjustment
are
appropriately
done
before
Calibration
mode
is
executed.
The
Calibration
mode
can
be
executed
by
pushing
buttons
on
a
control
panel.
Please
use
headphones
with
appropriate
volume
level
when
you
check
the
buzzer
sound.
Measurement
by
calibration
mode
shall
be
required
in
the
following
cases:
・
If
the
piano
performance
is
not
good
enough
in
Silent
mode.
・
When
replacing
the
key
sensor
rail,
damper
pedal
sensor
and
Switch
box.
・
When
adjusting
the
action
mechanic
or
pedals.
For
key
sensor
measurement,
there
are
“All
‐
key
measurement”
to
rewrite
the
measurement
of
all
of
the
keys,
and
“1
‐
key
measurement”
to
rewrite
only
a
designated
key.
‐ 12 ‐