For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
93/273
(2) Shutter Open/Close Speed Adjustment
Adjust the speed controller (SPICON) to set the shutter open/close time as follows.
Open: 80 +/- 5msec. (From valve signal ON to sensor OFF)
Close: 80 +/- 5msec. (From valve signal OFF to sensor ON)
3.1.5.3. Nozzle Up-Status Detection Sensor Amplifier Adjustment
(1)
Amplifier Cable Wiring Arrangement
a.
Standard: The nozzle stocker for multi-functional nozzle is setup in the first line.
b. Standard: The nozzle stocker for multi-functional nozzle is setup in the Fouth line.
c. Standard: The nozzle stockers for multi-functional nozzle are setup in first and the
fourth lines.
(2)
Sensor Amplifier Teaching
Set the nozzle up-status detection fiber amplifier using the following procedure.
CH1
:
Connection
CH2
:
Use a snippet of the fiber cable.
CH1
:
Use a snippet of the fiber cable.
CH1
:
Connect the first line.
CH2
:
Connect the four line.
Fig.C16