27
T7. KEYBOARD
This test is used to check that the keyboard functions
properly by scaling 88 keys from A1 to C7.
(The above shows the C1 check.)
x x x x
: velocity value of the key being pressed
When the key on the LCD display works at a velocity of
0X10 to 0X6F, it is considered normal and that keys note
is output. The test will then proceed to the next key test.
If a wrong key is played, “NG” will appear and that note’s
sound will not be output. If a correct key is played after
that, however, the test will proceed to the next key test.
If the test results of all the keys are satisfactory, “OK”
will appear on the LCD display.
DISPLAY OF RESULTS
OK
NG
TEST END
If the test results of all the keys are satisfactory, “OK”
will appear and testing will end.
When the test result is “NG”, refer to “C. TEST
S E L E C T I O N W H E N A N E R R O R H A S B E E N
DETECTED”.
T8. A. KNOB A-2
Move each knob gradually in the following order: Center
64 (63-65); Left 127 (126-127); Right 0 (0-1); Center 64
(63-65), according to the instruction on the LCD as shown
below. Check that the numbers change sequentially and
that “OK” appears as the result.
Begin the check from the specified knob. The mark [>] will
appear to the left of the value of the knob being checked.
x x x
: current knob value
y y y
: next target value
DISPLAY OF RESULTS
OK
NG
(No change in the message on the display)
TEST END
The test ends after the results have been displayed.
When the test result is “NG”, refer to “C. TEST
S E L E C T I O N W H E N A N E R R O R H A S B E E N
DETECTED”.
T9. SLIDER 1-4
Move each slider in the following order: Down 0 (0-1);
Up 127 (126-127); Down 0 (0-1), according to the
instruction on the LCD. Check that the numbers change
sequentially and that “OK” appears as the result.
Begin the check from the specified slider. The mark [>] will
appear to the left of the value of the slider being checked.
x x x
: current slider value
y y y
: next target value
DISPLAY OF RESULTS
OK
NG
(No change in the message on the display)
TEST END
The test ends after the result is displayed.
When the test result is “NG”, refer to “C. TEST
S E L E C T I O N W H E N A N E R R O R H A S B E E N
DETECTED”.
Содержание S-80
Страница 30: ...S80 34 ...
Страница 31: ...S80 35 ...
Страница 32: ...S80 36 ...
Страница 33: ...S80 37 ...
Страница 34: ...S80 38 ...
Страница 35: ...S80 39 ...
Страница 36: ...S80 40 ...
Страница 37: ...S80 41 ...
Страница 38: ...S80 42 ...
Страница 39: ...S80 43 ...
Страница 44: ...S80 48 ...
Страница 45: ...S80 49 ...