CONNECTIONS
Setting up the speaker parameters automatically (YPAO)
En
40
■
Message list
■
When a warning message is displayed before
measurement
■
Error messages
NOTE
If the following messages appear, resolve the problems that have
occurred and carry out the measurement process again.
Connect MIC!
The YPAO microphone is
not connected.
Connect the YPAO
microphone to the YPAO
MIC jack on the front
panel.
Unplug HP!
The headphones are
connected.
Remove the headphones.
Memory Guard!
The settings of this unit
are protected.
Set “Memory Guard” in
the Setup menu to “Off”
(
☞
p. 112
).
E-1:
No Front SP
The unit was not able to
find the front channel.
Check that the left and
right front speakers are
connected correctly.
E-2:
No Sur. SP
The unit was only able to
find one of side of the
surround channels.
Check that the left and
right surround speakers
are connected correctly.
E-3:
No F.PRNS SP
The unit was only able to
find one of side of the
presence channels.
Check that the left and
right presence speakers
are connected correctly.
E-4:
SBR
→
SBL
Only one surround back
speaker is connected and
only the right side
surround back channel
sound is detected.
When only one surround
back speaker is
connected, connect to the
left side (SINGLE)
terminal.
E-5:
Noisy
The noise is too loud,
preventing accurate
measurements from
being taken.
Measure again in quiet
surroundings. Turn off any
devices in the room that
may be emitting noise, or
place them further away
from the YPAO
microphone.
When this message is
displayed, selecting
“PROCEED” will allow
you to continue measuring.
However, we recommend
resolving the problem and
measuring again, as
continuing measurement
without doing so will not
give accurate results.
E-6:
Check Sur.
Even though surround
left and right speakers are
not connected, only the
surround back speakers
are connected.
When using surround back
speakers, connection of the
surround left/right
speakers is necessary.
E-7:
No MIC
The YPAO microphone
has been removed.
While measuring, take
care not to touch the
YPAO microphone.
E-8:
No Signal
The YPAO microphone
could not distinguish a
test tone.
Check that the YPAO
microphone has been
installed correctly.
Check that each speaker
has been connected and
installed correctly.
The YPAO microphone
or the YPAO MIC jack
may be broken. Inquire at
the retailer where you
purchased this unit, or the
nearest Yamaha service
center.
E-9:
User Cancel
You have carried out an
operation that has
cancelled the measuring
process.
Carry out the measuring
process again. Do not
operate this unit by, for
example, adjusting the
volume.
E-10:
Internal Error
An internal error has
occurred.
Carry out the measuring
process again. Contact a
Yamaha service center if
“E-10” is displayed
again.