10. AD DATA CHECK
This menu is used to display the A/D conversion value of the main CPU which detects panel keys of the main unit and
protection functions in % using the sub-menu. (Reference voltage 5V as 100%) During signal processing, the condition
before execution is maintained.
When in K0/K1 page, it is not possible to operate the keys of the main unit because the values of all keys are detected. But
one click on the volume encoder of the main unit to the right or left will cancel this function and sets to the next sub-menu.
Note, however, that clicking there more than once would change the DIAG menu. In such a case, return to the DIAG menu
which has been used for measurement. During signal processing, the condition before execution of this menu is maintained.
Display
K0
K1
0
PRESET
¶
6CH INPUT
10
PRESET
•
INPUT
¶
20
PRESET/TUNING INPUT
•
30
FM/AM
INPUT MODE
40
MEMORY
SPEAKERS A
50
TUNING MODE
SPEAKERS B
60
RDS MODE
EFFECT
70
RDS EON
PROGRAM
¶
80
PTY MODE
PROGRAM
•
90
PTY START
A/B/C/D/E
100
KEY OFF
KEY OFF
[Table 1]
20
REC OUT
[Remote control code: –]
RX-V800 does not use this sub-menu.
K0/K1
(Panel key of main unit) [Remote control code: –]
A/D of the key fails to function properly when the standard value is deviated by
±4%. In this case, check the constant of partial pressure resistor, solder
condition, etc.
DC/PS
(Protection) [REMOTE CONTROL CODE: 7A-0B (CD SKIP-)]
DC: DC detect protection value (Normal value: 1 to 13)
PS: Power voltage protection value (Normal value: 18 to 32)
* If DC or PS is out of the normal value range, the protection function works to
turn off the power.