RX-V357/HTR-5830
20
RX-V357/HTR-5830
DIAG menu selection
Keys of main unit
SUB-MENU selection
When there is a history of protection
function due to excessive heat sink
temperature
Version (1 alphabet)
Voltage display in %
When there is a history of protection
function due to abnormal DC output
Version (1 alphabet)
Cause:
DC output of the power amplifier is abnormal.
Turning on the power without correcting the abnormality
will cause the protection function to work 3 seconds later
and the power supply will be shut off.
Cause:
The temperature of the heat sink is excessive.
Supplementary information:
The abnormal voltage is
displayed in % based on 5V as 500%.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
* Additional causes of protection can be due to loose
connections, associated components, CPU, etc.
* For the protection voltage value, refer to DIAG menu
No.10 described later.
• History of protection function
When the protection function has worked, its history is
stored in memory with a backup. Even if no abnormality
is noted while servicing the unit, an abnormality which
has occurred previously can be defined as long as the
backup data has been stored.
The history of the protection function is cleared when
DIAG is cancelled by selecting PRESET RESERVED
(Memory initialized) of DIAG menu No.9 or when the
backup data is erased.
• Display during menu operation
During the DIAG operation, the function at work is
indicated on the FL indicator. The contents displayed
during the function operation are described in the later
section on details of functions.
• Functions in DIAG mode
In addition to the DIAG menu items, functions as listed
below are available.
• Input selection, 6CH input
• Center/Surround/Sub-woofer level adjustment
• Muting
• Power on/off
• Master volume
* Functions related to the tuner and the set menu are not
available.
* It is possible to confirm Menu No.11 IF STATUS while
keeping the signal process (operation status) of each
DIAG menu by using the input mode key of the main
unit.
• Initial settings used to start DIAG
The following initial settings are used when starting DIAG.
When DIAG is canceled, these settings are restored to
those before starting DIAG.
• Master volume: -24dB
• Input: DVD (6CH INPUT OFF)
• Effect level: 0dB
• Audio mute: OFF
• Speaker setting: LARGE / BASS OUT = BOTH
• DIAG menu: DSP THROUGH (1. ANALOG BYPASS)
• Operation procedure of DIAG menu and
SUB-MENU
There are 15 MENU items, each of which has some SUB-
MENU items.
DIAG menu selection
Main unit: Select the menu using (Forward) and
(Reverse) PROGRAM keys.
SUB-MENU selection
Main unit: Select the sub-menu using - and + BASS/
TREBLE keys.
Содержание RX-V357
Страница 5: ...RX V357 HTR 5830 5 RX V357 HTR 5830 REAR PANELS RX V357 R model RX V357 C model RX V357 T model ...
Страница 6: ...RX V357 HTR 5830 6 RX V357 HTR 5830 RX V357 K model RX V357 B G E models RX V357 A model ...
Страница 7: ...RX V357 HTR 5830 7 RX V357 HTR 5830 HTR 5830 U C models RX V357 L model HTR 5830 R model ...
Страница 8: ...RX V357 HTR 5830 8 RX V357 HTR 5830 HTR 5830 T model HTR 5830 A model HTR 5830 K model ...
Страница 70: ...RX V357 HTR 5830 本资料由OKXIA视听皮带资源库www okxia cn提供 ...