Yamaha PW3000M Скачать руководство пользователя страница 4

 

4

 

 

Front panel

 

 

Rear panel

 

The PW3000M power supply should be installed in a well 
ventilated location.
In particular, the front and rear panels must not be 
blocked, since the ventilation path passes through them.

 

A

 

POWER ON/OFF

 

 switch

 

After connections to the M3000 have been completed, 
turn this switch on to supply power to the M3000.

 

B

 

Operation monitor

 

Four LEDs indicate the status of the power that is 
being supplied to the M3000. Normally (i.e., when no 
malfunction has occurred), the green LEDs (NOR-
MAL) will light. If a malfunction occurs, the LED for 
that section of the power supply will go dark. Turn the 
power off and wait for a time before turning the 
power on again. If the same LED(s) are dark, contact a 
Yamaha service center.

 

C

 

GND terminals

 

This is the grounding screw terminal. If hum or noise 
occurs, ground (earth) the unit via this jack, or try 
connecting it to the chassis of the other device.

 

D

 

DC OUTPUT

 

 connector

 

Connect this connector to the M3000 to supply power 
to it.

 

E

 

DC PARALLEL INPUT

 

 connector

 

This connector allows two PW3000M units to be con-
nected in parallel. As shown in the following diagram, 
use the included parallel connection cable to make 
connections. In this case, the two PW3000M units will 
each supply 50% of the power in normal operation. 
Even in the unlikely event that one of the PW3000M 
units failed, the other PW3000M will supply 100% of 
the power, ensuring an uninterrupted power supply.

POWER

OPERATION MONITOR

POWER SUPPLY

ON/    OFF

NORMAL

+48V

+12V

+15V

–15V

1

2

DC OUTPUT

CONNECT

DISCONNECT

PIN 2 +15V 4.2A

PIN 5 –15V 4.2A

PIN 6 +12V 4.1A

PIN 9 +48V 0.2A

DC PARALLEL INPUT

CONNECT

DISCONNECT

5

4

3

DC OUTPUT

CONNECT

DISCONNECT

PIN 2 +15V 4.2A

PIN 5 –15V 4.2A

PIN 6 +12V 4.1A

PIN 9 +48V 0.2A

DC PARALLEL INPUT

CONNECT

DISCONNECT

DC OUTPUT

CONNECT

DISCONNECT

PIN 2 +15V 4.2A

PIN 5 –15V 4.2A

PIN 6 +12V 4.1A

PIN 9 +48V 0.2A

DC PARALLEL INPUT

CONNECT

DISCONNECT

M3000

PW3000M

PW3000M

DC POWER
INPUT

DC OUTPUT

DC OUTPUT

DC PARALLEL 
INPUT

Содержание PW3000M

Страница 1: ...POWER SUPPLY Owner s Manual Mode d emploi Bedienungsanleitung M ...

Страница 2: ...ng measures Relocate either this product or the device that is being affected by the interference Utilize power outlets that are on different branch circuit breaker or fuse circuits or install AC line filter s In the case of radio or TV interference relocate reorient the antenna If the antenna lead in is 300 ohm ribbon lead change the lead in to coaxial type cable If these corrective measures do n...

Страница 3: ...ee air space around the power supply unit If the power supply unit is to be rack mounted leave at least 10 cm free above the top panel and behind the rear panel When the power supply unit is in use remove the rear of the rack or open its ventilation slots to prevent overheating which could be a fire hazard Do not try to modify the power supply unit This could be a fire and electrical shock hazard ...

Страница 4: ...sis of the other device D DC OUTPUT connector Connect this connector to the M3000 to supply power to it E DC PARALLEL INPUT connector This connector allows two PW3000M units to be con nected in parallel As shown in the following diagram use the included parallel connection cable to make connections In this case the two PW3000M units will each supply 50 of the power in normal operation Even in the ...

Страница 5: ...Power Consumptions USA and Canada 400 W 540 VA Europe 380 W Others 380 W Dimension W x H x D 480mm x 103 5mm x 455mm Weight 15kg Pin No Signal name Power supply connector 1 Power supply remote 2 15 V 3 15 V GND 4 48 V GND 5 15 V 6 12 V 7 12V GND power supply remote 8 Power supply remote 9 48 V 10 FRAME GND DC OUTPUT DC PARALLEL INPUT 1 2 3 8 9 10 5 4 6 7 3 2 1 10 9 8 6 7 5 4 D 455 W 480 88 H 103 5...

Отзывы: