PM1D Manager V2 for Windows Owner’s Manual

10

Communication between PM1D Manager and the console/engine

If you connect the console/engine and the PC, you can use PM1D Manager as a supplementary controller for 
the system.

Online

” refers to a state in which the console/

engine and the PC are connected by a cable, and data 
can be transferred to control the device immediately.

Offline

” refers to a state in which the console/

engine and the PC are not connected by a cable and 
therefore are unable to communicate, or a state in 
which the cable is connected but communication has 
not begun.

In the online state, parameters (with some excep-
tions) will be linked between the console/engine and 
the PC, allowing PM1D Manager to monitor the 
state of the system, operate it remotely, and act as a 
substitute in the event of device failure. The material 
that follows will explain various ways of setting up 
the system, and how data communications can be 
established and terminated.

System connection examples

Example 1: Standard mode (connect the PC 
to the console)

Console

×

1, Engine

×

1

Example 2: Standard mode (connect the PC 
to the engine)

Example 3: Mirror mode (connect the PC to 
the console)

Console

×

1, Engine

×

2 (mirror mod

e

)

Example 4: Mirror mode (connect the PC to 
the engine)

Console

×

1, Engine

×

2 (mirror mode)

The PC can only be connected to the engine that is 
selected in Mirror mode. In this example, ENGINE A 
is used.

The PC can only be connected to the engine that is 
selected in Mirror mode. In this example, ENGINE B 
is used.

Example 5: Normal mode (connect the PC to 
the engine)

Engine

×

1

• Only one PC can be connected to a system. It is not possi-

ble to connect multiple PC’s to a system.

• Depending on the device to which the PC is connected, or 

depending on the structure of the system, the functional-
ity of PM1D Manager may be partially limited. For 
details, refer to “PC connections in a system that includes 
a console” (

p.21).

CONSOLE

(CS1D)

ENGINE

(DSP1D)

CONSOLE

(CS1D)

ENGINE

(DSP1D)

CONSOLE

(CS1D)

ENGINE A

(DSP1D)

ENGINE B

(DSP1D)

CONSOLE

(CS1D)

ENGINE A

(DSP1D)

ENGINE B

(DSP1D)

CONSOLE

(CS1D)

ENGINE A

(DSP1D)

ENGINE B

(DSP1D)

ENGINE

(DSP1D)

Содержание PM1D Manager V2

Страница 1: ...d Trademarks Windows is a registered trademark of Microsoft Corporation in the United States and other countries Pentium II is a registered trademark of Intel Corporation Compact Flash is a trademark...

Страница 2: ...display common to all screens 7 Lower part of the display common to all screens 7 Lower part of the function menu 8 Option popup window 8 REMOTE CONTROL SETUP popup window 9 Communication between PM1...

Страница 3: ...rols of the console and the knobs buttons of the software The names of controls on the console switches encoders are enclosed in square brackets in order to distinguish them from the knobs and buttons...

Страница 4: ...em you may be asked to restart the system during the installation process If so installation will continue automatically after you restart 3 As directed by the instructions on the screen click the Nex...

Страница 5: ...ther of the following methods to start up PM1D Manager 1 From the Windows Start menu select Start Programs YAMAHA PM1D System PM1D Manager 2 Double click the PM1D Manager icon that was cre ated during...

Страница 6: ...k either the Initialize All Memories button or the Initialize Current Memories button If you click the Initialize All Memories button The current settings of the PM1D Manager as well as the scene memo...

Страница 7: ...ication Setup Lower part of the display common to all screens 1 RECALL button MUTE button Select the function of the DIRECT RECALL MUTE MASTER 1 12 buttons 2 from the following two choices DIRECT RECA...

Страница 8: ...func tion menu screen or choose Manager from the Option menu of the menu bar 1 Communication Setup Communication Port From the pulldown menu select the port that will be used for communication Only C...

Страница 9: ...r has been established 4 CH ASSIGN Here you can assign the correspondence between input channels of the remote controller and input channels of the PM1D in units of two channels If you don t want to m...

Страница 10: ...ed and terminated System connection examples Example 1 Standard mode connect the PC to the console Console 1 Engine 1 Example 2 Standard mode connect the PC to the engine Example 3 Mirror mode connect...

Страница 11: ...off the console engine or connect disconnect cables If you perform these actions before exiting communication may become impossible until you restart your PC USB connection is not guaranteed to be fa...

Страница 12: ...nd slave are handled separately so this is considered as two systems 6 In the Function menu screen click the ONLINE OFFLINE button The following popup window will appear In this popup window you can s...

Страница 13: ...to the engine system example 4 on p 10 When a console is connected to a system that consisted of only an engine and a PC system example 5 on p 10 When the cable connection is accidentally broken or if...

Страница 14: ...1 3 Start up PM1D Manager and open the Option popup window either by clicking the OPTION but ton in the lower left of the function menu screen or by choosing Manager Option from the Option menu in the...

Страница 15: ...G Hi Mid Q Hi Mid Q Hi Mid F Hi Mid F Hi Mid G Hi Mid G Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF or LPF Hi F Hi Mid F Hi G Hi Mid G Hi LPF Ignored LPF On On On Input...

Страница 16: ...G Ignored HPF On SubLow On Ignored Low Q Low Mid Q Low F Low Mid F Low G Low Mid G Low On Ignored Low Mid Q Hi Mid Q Low Mid F Hi Mid F Low Mid G Hi Mid G Low Mid On Ignored Mid Q Mid F Mid G Mid On I...

Страница 17: ...id G Low Mid On Ignored Mid Q Ignored Mid F Ignored Mid G Ignored Mid On Ignored Hi Mid Q Hi Mid F Hi Mid G Hi Mid On Ignored Hi LPF Hi Q When LPF Hi H SHELF When H SHELF Hi Q When other than H SHELF...

Страница 18: ...Hi LPF Ignored LPF On Hi On Ignored On On Stereo Comp Ignored Stereo Comp LocComp On On Ignored Link Type Type Attack Attack Release Release Ratio Ratio Gain Gain Knee Knee Threshold Threshold Input...

Страница 19: ...n 16 the data is fixed as space on the remote controller Mute Master 9 12 Output Mute Master Surround Mode Surround Mode Input CH Name Short Input CH Name Short column1 4 Input CH Name Long Input CH N...

Страница 20: ...recall occurs MIDI program changes control changes The MIDI ports of the PC cannot be used as MIDI inputs outputs for the PM1D Manager software TC events The setting can always be made but since oper...

Страница 21: ...e in the system and can therefore be operated independently LOAD SAVE screen The number of characters that can be used in a file name is eight characters plus the filename extension PM1 If this number...

Страница 22: ...n the Copy files from sec tion of the subsequent dialog box enter D USBdrv2k_ replacing D with the drive letter of your CD ROM drive and then click OK The driver is installed and the message Completin...

Страница 23: ...SB Driver fails the CS1D DSP1D may be registered as an unknown device and you may not be able to rein stall the driver until the unknown device is deleted In this case open the System control panel cl...

Страница 24: ...U R G Pro Audio Digital Musical Instrument Division Yamaha Corporation 2002 Yamaha Corporation WF52700 806IPAPx x 0xA1 Printed in Japan...

Отзывы: