background image

11

Specifications

General Specifications

PC9500N

PC4800N

120 V (US)/ 240 V (A) 230 V (EU)

120 V (US)/ 240 V (A)

230 V (EU)

Power Output Level (Rated Power) 8

/STEREO

1000 W x 2

1050 W x 2

550 W x 2

500 W x 2

1 kHz

4

/STEREO

1600 W x 2

1650 W x 2

850 W x 2

800 W x 2

THD+N= 1%

8

/BRIDGE

3200 W x 1

3300 W x 1

1700 W x 1

1600 W x 1

8

/STEREO

925 W x 2

950 W x 2

475 W x 2

450 W x 2

20 Hz–20 kHz

4

/STEREO

1400 W x 2

1500 W x 2

725 W x 2

700 W x 2

THD+N= 0.1%

8

/BRIDGE

2800 W x 1

3000 W x 1

1450 W x 1

1400 W x 1

1 kHz

2

/STEREO

2300 W x 2

2300 W x 2

1200 W x 2

1200 W x 2

20mS nonclip

4

/BRIDGE

4600 W x 1

4600 W x 1

2400 W x 1

2400 W x 1

Power Bandwidth

Half Power

10 Hz–40 kHz (THD+N= 0.5%)

Total Harmonic Distortion (THD + N)

20 Hz~20 kHz, Half Power

0.1%

Frequency Response

RL= 8

, Po= 1 W

0 dB, 0.5 dB, –1 dB     f=20 Hz–50 kHz

Intermodulation distortion (IMD)

60 Hz:7 kHz, 4:1, Half Power

0.1%

Channel Separation

Half Power, RL= 8

, 1 kHz

70 dB

Vol. max., input 600

 shunt

Residual Noise     Vol. min.

20 Hz~20 kHz (DIN AUDIO)

 –70 dB

SN Ratio

20 Hz~20 kHz (DIN AUDIO)

106 dB

103 dB

Damping Factor

RL=8

, f= 1 kHz

800

Sensitivity (Vol. max.) Rated Power into 8

+9 dB

+6 dB

Voltage Gain (Vol. max.)

32 dB

Input Impedance

30 k

/Balanced,  15 k

/Unbalanced

Controls

Front Panel

POWER switch (ON/OFF)
Volume (31 position) /ch

Rear Panel

MODE switch (STEREO/BRIDGE/PARALLEL)
HPFswitch (ON/OFF)  fc=40 Hz 12dB/octave
DIP switch (6P)

Connectors

Input

XLR-3-31 type/ch
Euroblock connector /ch

Output

SPEAKON /ch, 5-way binding posts

NETWORK

RJ45 x 2

POWER

AC INLET

Indicators

POWER/STAND-BY

Green/Orange

PROTECTION

Red

TEMP

Red (heatsink temp 

 85

°

C)

REMOTE

Green

Meters

10 points LED meter

Load protection

POWER switch ON muting, DC detection

Amp. protection

Temp. detection (heatsink temp 

 90

°

C), VI limiter (R

L

 

 1 

)

Limiter

Comp. : THD 

 0.5%

Cooling

Dual Variable-speed fan

Power Requirements

US & Canada

120 V, 60 Hz

Europe

230 V, 50/60 Hz

Other

240 V, 50/60 Hz

Power Consumption

Idling

55 W

40 W

Output power, 4

120 V 750 W   230 V 1100 W

120 V 450 W   230/240 V 600 W

240 V 1000 W

Dimensions (W x H x D)

480 x 88 x 456 mm

Weight

13 kg

12.5 kg

Accessories

Power cord, Security cover, Owner’s Manual, Euroblock connector (2)

0 dB=0.775 Vrms, Half Power=1/2 Power Output Level (Rated Power)
Specifications subject to change without notice.

For European Model
Purchaser/User information specified in EN55103-1 and EN55103-2.
Inrush Current: 20A (PC9500N) / 25A (PC4800N)
Conformed Environment: E1, E2, E3 and E4.

Содержание PC4800N

Страница 1: ...POWER AMPLIFIER Owner s Manual E ...

Страница 2: ...h FCC regulations does not guarantee that interference will not occur in all installations If this product is found to be the source of interference which can be determined by turning the unit OFF and ON please try to eliminate the problem by using one of the following measures Relocate either this product or the device that is being affected by the interference Utilize power outlets that are on d...

Страница 3: ...k If you think internal inspection maintenance or repair is necessary contact your dealer Do not modify the unit Doing so is a fire and electrical shock hazard If lightning begins to occur turn off the power switch of the unit as soon as possible and unplug the power cable plug from the electrical outlet If there is a possibility of lightning do not touch the power cable plug if it is still connec...

Страница 4: ...tch off remove the power plug from the AC outlet and remove all connecting cables Damaged cables may cause fire or electrical shock Allow enough free space around the unit for normal ventila tion This should be 5 cm at the sides 10 cm behind and 10 cm above For normal ventilation during use remove the rear of the rack or open a ventilation hole If the airflow is not adequate the unit will heat up ...

Страница 5: ...below 40 Hz and detented attenuators and level meters for channels A and B are provided Metering and indicators include easily visible two channel level meters a PROTECTION indicator that shows the state of various protection systems power on off detection output protection DC detection a TEMP indicator that indicates heat sink overheating and a REMOTE indicator that indicates the external remote ...

Страница 6: ...rmal operation If a DC voltage is detected at the amplifier s outputs Turn off the power and then turn the power back on again If the amplifier overheats When this occurs the TEMP indicator will be lit You should turn off the amplifier and allow it time to cool down See the Precautions section of this Owner s Manual for ways to prevent the amplifier overheating 4 TEMP indicator This indicator will...

Страница 7: ...ng a 12 dB octave high pass filter 4 SPEAKERS jacks These are Speakon type output jacks Speakon type cable plugs can be connected here These are five way binding post output jacks 5 6 8 9 4 1 7 2 3 5 DATA ports An external control unit or interface box can be connected here to monitor or control the amplifier from the external device 6 AMP ID switch When an external control unit is connected to th...

Страница 8: ...er of speakers that are connected Refer to the following diagrams and make sure that the speaker impedance is not less than the value prescribed for each type of connection Connections in BRIDGE mode Speaker min 8Ω When using the Speakon connector Speaker min 8Ω Use the 1 and 2 pins of the 2 jack Connections in STEREO PARALLEL modes Speaker min 4Ω Speaker min 4Ω or ...

Страница 9: ...peaker terminals Screw 3 After removing approx 15 mm of insulation from the ends of the speaker cables pass the bare ends of the speaker wires through the holes in the corresponding speaker terminals and tighten the terminals to securely clamp the wires Refer to page 8 for speaker polarity 15mm Shown actual size At this time make sure that the bare ends of the speaker cables do not extend from the...

Страница 10: ...e rear panel of the rack and the rear panel of the amplifier Fan Use a fan with 1 5 m3 min or more maximum wind and 5 mmH2 O or more maximum static pressure Mounting Install the fan kit on the top slot or the top panel of the rack and install a blanking panel between two amps If the unit is rack mounted and transported frequently we recommend that the rear of the unit be supported by fitting a pai...

Страница 11: ...Power into 8Ω 9 dB 6 dB Voltage Gain Vol max 32 dB Input Impedance 30 kΩ Balanced 15 kΩ Unbalanced Controls Front Panel POWER switch ON OFF Volume 31 position ch Rear Panel MODE switch STEREO BRIDGE PARALLEL HPFswitch ON OFF fc 40 Hz 12dB octave DIP switch 6P Connectors Input XLR 3 31 type ch Euroblock connector ch Output SPEAKON ch 5 way binding posts NETWORK RJ45 x 2 POWER AC INLET Indicators PO...

Страница 12: ...12 Block Diagram ...

Страница 13: ...13 Dimensions Unit mm 480 88 456 46 4 380 26 25 30 370 30 25 ...

Страница 14: ...ted in the amplifier s output circuit Locate and remove the short Check the ventilation around the amplifier and improve the airflow if necessary Consult your dealer or a Yamaha service center The PC limiter circuit activates to protect the power transistors The thermal protection circuit activates to protect the power transistors The output relay activates to protect the speaker system Use a spea...

Страница 15: ......

Страница 16: ...YAMAHA CORPORATION V853450 R11 AP 16 Pro Audio Digital Musical Instrument Division P O Box 3 Hamamatsu 430 8651 Japan NP Printed in Taiwan ...

Отзывы: