N-100
35
TEST PROGRAM
1.
Preparation
To execute the test, the following measuring instruments and jigs are required. (Input impedance of the measuring instruments
should be 1 M
Ω
or more.)
· Level meter (with JIS-C filter)
· MIDI cable
Set the [MASTER VOLUME] to the maximum level and the leave the pedals turned off.
Connect a measuring plug (stereo plug) to the [PHONES] jack. (33
Ω
load)
2.
To enter Test Program
Turn on the power with [C#2], [F2] and [G#2] keys pressed and held simultaneously. (Fig. 1)
Once the Test Program is started properly, the sine wave of A3 sounds. To stop the sound, press the [DEMO] button.
3.
To proceed the test
Test items are listed in Table 1.
Press the corresponding key to select and execute each test. (See Fig. 2)
To enter the test item select mode after completing each test item, press the [DEMO] button.
C#2
F2
G#2
(Fig. 1)
4.
Test result
Each test result is indicated by the sound.
When the test result is OK, the sine wave of C4 sounds.
When the test result is NG, the sine wave of C2 sounds.
C0 D0
C#0 D#0
E0 F0 G0 A0
F#0 G#0 A#0
B0 C1 D1
C#1 D#1
E1 F1 G1 A1
F#1 G#1 A#1
B1 C2 D2
C#2 D#2
E2 F2 G2 A2
F#2 G#2 A#2
B2 C3 D3
C#3 D#3
E3 F3 G3 A3
F#3 G#3 A#3
B3 C4 D4
C#4 D#4
E4 F4 G4 A4
F#4 G#4 A#4
B4 C5 D5
C#5 D#5
E5 F5 G5 A5
F#5 G#5 A#5
B5 C6 D6
C#6 D#6
E6 F6 G6 A6
F#6 G#6 A#6
B6 C7
B-1
A-1
A#-1
1 3
2
9 11 13 15
10 12 14
Test No.
16 18
17 26
27 28 35 42
31 41
48
(Fig. 2)
Содержание N-100
Страница 25: ...N 100 25 JACK Circuit Board PN Circuit Board JACK 2NA WF51870 PN 2NA WF54150 1 Pattern side Pattern side ...
Страница 27: ...N 100 27 MAEQ Circuit Board 2NA WE74500 3 Pattern side Scale 80 100 ...
Страница 31: ...N 100 31 not installed B B to GHD M CN4 B B to GHD M CN2 2NAK8 V852140 Component side GHD H Circuit Board ...
Страница 34: ...N 100 34 2NA V001070 to MAEQ CN1 to POWER switch AC INLET not installed PS Circuit Board Component side ...