MX49/MX61 Data List
61
MIDI Data Table
TOTAL SIZE = 62
3E (HEX)
pp = part number
00 – 0F
Address
Size
Data
Range
(HEX)
Parameter Name
Description
Default
(HEX)
Notes
High Mid Low
37
pp
00
1
reserved
01
1
00 – 7F
Bank Select MSB
0 – 127
3F
02
1
00 – 7F
Bank Select LSB
0 – 127
00
03
1
00 – 7F
Program Number
1 – 128
00
04
1
00 – 0F,
7F
Receive Channel
1..16, off (7F)
Part
No.
05
1
00 – 01
Mono/Poly
mono, poly
01
06
1
01 – 7F
Velocity Limit Low
1 – 127
01
07
1
01 – 7F
Velocity Limit High
1 – 127
7F
08
1
00 – 7F
Note Limit Low
C-2 – G8
00
09
1
00 – 7F
Note Limit High
C-2 – G8
7F
0A
1
10 – 4C
Pitch Bend Range Upper
-48 – +12
42
0B
1
10 – 4C
Pitch Bend Range Lower
-48 – +12
3E
0C
1
00 – 7F
Velocity Sensitivity Depth
0 – 127
40
0D
1
00 – 7F
Velocity Sensitivity Offset
0 – 127
40
0E
1
00 – 7F
Volume
0 – 127
64
0F
1
01 – 7F
Pan
L63 – C – R63
40
10
2
00 – 0F
00 – 0F
Detune
-12.8 – +12.7 [Hz]
1st bit 3-0
bit 7-4,
2nd bit 3-0
bit 3-0
08
00
(80)
12
1
00 – 7F
Reverb Send
0 – 127
0C
13
1
00 – 7F
Chorus Send
0 – 127
00
14
1
reserved
15
1
00 – 7F
Dry Level
0 – 127
7F
16
1
28 – 58
Note Shift
-24 – +24 [semitones]
40
17
1
reserved
18
1
00 – 01
Param. with Voice
off, on
01
19
1
reserved
1A
1
00 – 01
Portamento Switch
off, on
00
1B
1
00 – 7F
Portamento Time
0 – 127
40
1C
1
00 – 01
Portamento Mode
fingered, fulltime
01
1D
1
reserved
1E
1
reserved
37
pp
1F
1
18 – 7C
Receive PB
Receive AT
Receive Program Change
Receive Bank Select
Receive Control Change
reserved
bit 6: off, on PB
bit 5: off, on AT
bit 4: off, on Program
Change
bit 3: off, on Bank Select
bit 2: off, on Control
Change
bit 1-0: reserved
7C
20
1
02 – 6F
Receive FC2
Receive FC1
reserved
Receive MW
Receive Sustain/Sostenuto
Receive Pan
Receive Volume/Expression
bit 6: off, on FC2
bit 5: off, on FC1
bit 4: reserved
bit 3: off, on MW
bit 2: off, on Sustain/
Sostenuto
bit 1: off, on Pan
bit 0: off, on Volume/
Expression
6F
21
1
00 – 7F
Receive Assignable Switch
2
Receive Assignable Switch
1
Receive Assignable Knob 2
Receive Assignable Knob 1
Receive RB
Receive BC
Receive FS
bit 6: off, on ASW2
bit 5: off, on ASW1
bit 4: off, on AKN2
bit 3: off, on AKN1
bit 2: off, on RB
bit 1: off, on BC
bit 0: off, on FS
7F
37
pp
22
1
00 – 01
Voice Element Pan
off, on
01
23
1
00 – 7F
AEG Attack Time
-64 – +63
40
24
1
00 – 7F
AEG Decay Time
-64 – +63
40
25
1
00 – 7F
AEG Sustain Level
-64 – +63
40
Only for
Normal
Voice
26
1
00 – 7F
AEG Release Time
-64 – +63
40
Only for
Normal
Voice
27
1
00 – 7F
FEG Attack Time
-64 – +63
40
Only for
Normal
Voice
28
1
00 – 7F
FEG Decay Time
-64 – +63
40
Only for
Normal
Voice
29
1
00 – 7F
FEG Sustain Level
-64 – +63
40
Only for
Normal
Voice
2A
1
00 – 7F
FEG Release Time
-64 – +63
40
Only for
Normal
Voice
2B
1
00 – 7F
FEG Depth
-64 – +63
40
Only for
Normal
Voice
2C
1
reserved
2D
1
00 – 7F
Filter Cutoff Frequency
-64 – +63
40
2E
1
00 – 7F
Filter Resonance
-64 – +63
40
37
pp
2F
1
reserved
30
1
reserved
31
1
reserved
32
1
reserved
33
1
reserved
34
1
reserved
35
1
reserved
36
1
reserved
37
1
reserved
38
1
reserved
39
1
reserved
3A
1
reserved
3B
1
reserved
37
pp
3C
1
00 – 7F
Assignable Knob 1 Value
-64 – +63
40
3D
1
00 – 7F
Assignable Knob 2 Value
-64 – +63
40
Address
Size
Data
Range
(HEX)
Parameter Name
Description
Default
(HEX)
Notes
High Mid Low
38
pp
00
1
00 – 01
ARP Switch
off, on
00
01
1
00 – 01
ARP MIDI Out Switch
off, on
00
02
1
00 – 0F
ARP Transmit Channel
1..16
Part No.
03
1
00 – 01
ARP Play Only
off, on
00
Determines
whether or not
the current Part
plays only the
note events of
the Arpeggio
playback
04
1
reserved
05
1
reserved
06
1
00 – 01
ARP Loop
off, on
01
07
1
00 – 02
ARP Hold
sync-off, off, on
01
08
1
00 – 06
ARP Unit Multiply
50%, 66%, 75%,
100%, 133%, 150%,
200%
03
09
1
00 – 7F
ARP Note Limit Low
C-2..G8
00
0A
1
00 – 7F
ARP Note Limit High
C-2..G8
7F
0B
1
01 – 7F
ARP Velocity Limit Low
1 – 127
01
0C
1
01 – 7F
ARP Velocity Limit High
1 – 127
7F
0D
1
00 – 04
ARP Key Mode
sort, thru, direct,
sort+direct,
thru+direct
00
0E
1
00 – 01
ARP Velocity Mode
original, thru
00
0F
1
00 – 01
ARP Change Timing
realtime, measure
01
10
1
01 – 07
ARP Quantize Value
32th, 16th_Triplet,
16th, 8th_Triplet, 8th,
4th_Triplet, 4th
03
11
1
00 – 64
ARP Quantize Strength
0...100%
00
12
2
00 – 01
00 – 48
ARP Velocity Rate
0...200%
00 64
14
2
00 – 01
00 – 48
ARP Gate Time Rate
0...200%
00
64
16
1
reserved
17
1
reserved
18
1
reserved
19
1
reserved
1A
2
00 – 01
08 – 78
ARP Swing
-120 … 0 … +120
01
00
1C
1
00 – 7F
ARP Accent Velocity
Threshold
off, 1 … 127
40
1D
1
00 – 01
ARP Accent Start
Quantize
off, on
01
1E
1
3D – 43
ARP Octave Range
-3 … 0 … +3
40
1F
1
36 – 4A
ARP Output Octave Shift -10 … 0 … +10
40
20
1
00 – 01
ARP Trigger Mode
gate, toggle
00
21
1
00 – 01
ARP Random SFX
off, on
01
22
1
00 – 01
ARP Random SFX Key
On Control
off, on
01
23
1
00 – 7F
ARP Random SFX
Velocity Offset
-64 … 0 … +63
40
24
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF1
-100 … 0 … +100
01
00
26
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF1
-100 … 0 … +100
01
00
28
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF2
-100 … 0 … +100
01
00
2A
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF2
-100 … 0 … +100
01
00
2C
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF3
-100 … 0 … +100
01
00
2E
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF3
-100 … 0 … +100
01
00
30
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF4
-100 … 0 … +100
01
00
32
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF4
-100 … 0 … +100
01
00
34
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF5
-100 … 0 … +100
01
00
36
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF5
-100 … 0 … +100
01
00
38
2
00 – 01
1C – 64
ARP Assign Velocity
Rate Offset SF6
-100 … 0 … +100
01
00
3A
2
00 – 01
1C – 64
ARP Assign Gate Time
Offset SF6
-100 … 0 … +100
01
00
Address
Size
Data
Range
(HEX)
Parameter Name
Description
Default
(HEX)
Notes
High Mid Low