Yamaha MV800 Скачать руководство пользователя страница 3

MV800 — Owner’s Manual

Important

Read the following before operating the MV800

Important

1

Warnings

• Do not place a container with liquid or small metal objects on top of this unit. Liquid or metal objects inside

this unit are a fire and electrical shock hazard.

• Do not allow water to enter this unit or allow the unit to become wet. Fire or electrical shock may result.
• Connect this unit’s power cord only to an AC outlet of the type stated in this Owner’s Manual or as marked on

the unit. Failure to do so is a fire and electrical shock hazard.

• Do not scratch, bend, twist, pull, or heat the power cord. A damaged power cord is a fire and electrical shock

hazard.

• Do not place heavy objects, including this unit, on top of the power cord. A damaged power cord is a fire and

electrical shock hazard. In particular, be careful not to place heavy objects on a power cord covered by a carpet.

• If you notice any abnormality, such as smoke, odor, or noise, or if a foreign object or liquid gets inside the unit,

turn it off immediately. Remove the power cord from the AC outlet. Consult your dealer for repair. Using the
unit in this condition is a fire and electrical shock hazard.

• Should this unit be dropped or the cabinet be damaged, turn the power switch off, remove the power plug

from the AC outlet, and contact your dealer. If you continue using the unit without heeding this instruction,
fire or electrical shock may result.

• If the power cord is damaged (i.e., cut or a bare wire is exposed), ask your dealer for a replacement. Using the

unit with a damaged power cord is a fire and electrical shock hazard.

• Except for the safety cover, never remove anything else from this device. (Please refer to page 8 about the Euro-

block connectors.)  You could receive an electrical shock. If you think internal inspection, maintenance, or
repair is necessary, contact your dealer.

• Do not modify the unit. Doing so is a fire and electrical shock hazard.
• If lightning begins to occur, turn off the power switch of the unit as soon as possible, and unplug the power

cable plug from the electrical outlet.

• If there is a possibility of lightning, do not touch the power cable plug if it is still connected. Doing so may be

an electrical shock hazard.

Cautions

• When rack-mounting the unit, allow enough free space around the unit for normal ventilation. This should

be: 10 cm at the sides, 40 cm behind, and 30 cm above.
For normal ventilation during use, remove the rear of the rack or open a ventilation hole.
If the airflow is not adequate, the unit will heat up inside and may cause a fire.

• This unit has ventilation holes at the top, bottom, and sides to prevent the internal temperature rising too

high. Do not block them. Blocked ventilation holes are a fire hazard.

• Hold the power cord plug when disconnecting it from an AC outlet. Never pull the cord. A damaged power

cord is a potential fire and electrical shock hazard.

• Do not touch the power plug with wet hands. Doing so is a potential electrical shock hazard.

Operating Notes

• Using a mobile telephone near this unit may induce noise. If noise occurs, use the telephone away from the

unit.

• XLR-type connectors are wired as follows:

pin 1: ground, pin 2: hot (+), and pin 3: cold (-).

• Refer to the “Connector polarity” chart on page 7 for information on the pin wiring of the XLR connector and

phone jack.

• The performance of components with moving contacts, such switches, rotary controls, faders, and connectors,

deteriorates over time. The rate of deterioration depends on the operating environment and is unavoidable.
Consult your dealer about replacing defective components.

• Use only the specific screws that are provided with the MV800 to attach the supplied security cover.  Also, after

wiring the Euro-block connectors, use the same screws that held the security cover in place when replacing the
cover.
The use of any other screws may result in damage.

Содержание MV800

Страница 1: ...s the MV800 also offers individual control of those two zones directly from the front panel without the need to change the wiring making it an excellent mixer for banquet rooms etc In order to get the most out of your MV800 and its excellent functions and to enjoy years of trouble free use please read this Owner s Manual thor oughly before using And please keep it in a safe place for future refere...

Страница 2: ...minals in your plug proceed as follows The wire which is coloured GREEN and YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN and YELLOW The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK The wire which is coloured BROWN must be connected to the term...

Страница 3: ...ssary contact your dealer Do not modify the unit Doing so is a fire and electrical shock hazard If lightning begins to occur turn off the power switch of the unit as soon as possible and unplug the power cable plug from the electrical outlet If there is a possibility of lightning do not touch the power cable plug if it is still connected Doing so may be an electrical shock hazard Cautions When rac...

Страница 4: ...ctors to be connected to individual channels Equipped with two ZONE buses that include not only monaural and stereo channels but also REC OUT and OUTPUT jacks a single MV800 easily provides sound control for two rooms Separate REC OUT jacks are supplied for both ZONES 1 and 2 allowing easy recording to a tape deck Along with XLR and phone jacks Euro block connectors are also supplied for the main ...

Страница 5: ... center position r ZONE Select Switch Sends each channel s signal to the ZONE 1 bus and or ZONE 2 bus When the switch is ON the signal is sent to the relative bus t PEAK Indicator The indicator detects peaks in the signal after it has passed the EQ The indicator will light red when the level reaches 17dB to warn that clipping is imminent y SIGNAL Indicator The indicator lights when the signal s le...

Страница 6: ...input level Threshold level at which the compressor will function Rotating the control to the right allows the compressor to function at lower volume levels RATIO Control Sets the ratio of compression that is applied to the signal when it exceeds the threshold level Rotating the knob to the right increases the amount of compres sion When the knob is turned fully to the left the signal will not be ...

Страница 7: ... L and R channels are to be mixed as a monaural signal 2 ZONE 1 TO 2 Switches Set the switch to its ON position to send the signal from ZONE 1 pre volume to ZONE 2 pre volume In this case the ZONE 1 pre volume signal will be sent to the ZONE 2 output jacks and that signal s volume can be adjusted with the ZONE 2 Volume control 3 POWER Indicator The indicator will light when the unit s power is ON ...

Страница 8: ...e transformer is ungrounded MIC Compatible with 50 600Ω microphones LINE Compatible with 600Ω line level devices INSERT IN Jack INSERT OUT Jack These are input output jacks that are positioned between the noise gate and channel volume of the input channel The INSERT IN jack is a balanced phone type jack with a nominal input impedance of 0dB 600Ω The INSERT OUT jack is balanced phone type jack with...

Страница 9: ...d the same signal that is sent from the ZONE OUT jacks The signal from ZONE 1 is sent to the 1L and 1R jacks while the ZONE 2 signal is sent to the 2L and 2R jacks The signal sent from these jacks is not affected by the ZONE volume controls Make recording level adjustments on the recording device Also the ZONE 1 TO 2 switch is ineffective with these jacks y ZONE OUTPUT Jacks ZONE 1 L R ZONE 2 L R ...

Страница 10: ...t the wires according to the jack s pole display and turn the upper screw to the right to secure the wire 3 Connect the Euro block connector to the mixer s jack r Replace the cover and re attach it in its original location Caution Electric shock may occur if the Euro block connectors are used without the cover attached Feet Four rubber feet are supplied with the mixer According to the orientation ...

Страница 11: ...en difficult to hear the speaker over the music In this case it is necessary to reduce the BGM volume raise the microphone s volume or both If so it is impossible to safely leave the mixer for any length of time In such cases the Stereo Channel Ducker Function is very useful This function automatically reduces the volume of the BGM source that is connected to the ST Input jacks A B when a signal e...

Страница 12: ...araoke songs sung by the party guests A pair of headphones connected to the PHONES jack can be used to monitor the overall volume balance etc Connections ZONE 2 Assign the Karaoke room to ZONE 2 q Connect microphones to the INPUT jacks of channels 5 and 6 If a condenser microphone is used set the Input Select Switch to its MIC 48V position if a microphone other than a condenser microphone is used ...

Страница 13: ...araoke Power Amp Speakers DVD Player for Karaoke Set the ZONE 1 switch to ON on CH 1 4 only ST CH DUCKER Switch ON Reverb Unit Reverb Unit Set the ZONE 2 switch to ON on CH 5 8 only Set the ZONE 1 switch to ON on ST CH only ZONE AFL Select Switch Select the zone you want to monitor Set the 1 TO 2 Switch OFF Cassette Deck for recording ZONE 1 Cassette Deck for recording ZONE 2 If necessary setup th...

Страница 14: ...amp lights when a large signal is present Use the volume control on the power amp to adjust the volume delivered by the speakers If necessary setup the PAGING system Connect a pair of headphones to the PHONES jack and set the ZONE AFL Select Switch to ZONE 1 AFL to monitor the final output Setting ZONE 2 Channel 5 and 6 Settings 1 Make the following settings Channel Volume Gate Switch ON ZONE Sele...

Страница 15: ...t EQ signal level exceeds that of the noise gate s threshold level Stereo input indicator PEAK red The indicator will light when the post buffer amp signal level exceeds 17dB SIGNAL green The indicator will light when the post buffer amp signal level exceeds 10dB Compressor indicator Orange When the compressor is activated the indicator will light Stereo channel ducker indicator Orange When the St...

Страница 16: ...nsitivity the lowest level that will produce the nominal output level when the unit is set to maximum gain 2 XLR type connector Euro block connector phone jack TRS T Hot R Cold S Gnd balanced type 3 RCA phono jack phone jack TRS T ZONE 1 R ZONE 2 S Gnd unbalanced type 0dB 0 775Vrms 0dBV 1Vrms Output Specifications Output connectors Output Nominal Output level Connector type impedance impedance Nom...

Страница 17: ...MV800 Owner s Manual Supplement 15 429 87 5 479 88 301 337 325 Units mm Dimensions ...

Страница 18: ...dBV L R ST MONO ST ST M M SUM SUM INV INV REC1 OUT 10dBV L R LEVEL 6dB 0dB BA G PEAK SIGNAL CONTROL IN PAGING ON TH OFF OFF OFF OFF ON ON ON ON PAGING ON ZONE1 DUCKER ZONE2 DUCKER 0dB PAD HA PAGING MIC 60 16dB LINE 34 10dB G MIC 48V MIC LINE GAIN 60 16dB 34 10dB 48V STACK OUT 0dB SUM SUM COMP CHANNEL COMP OFF COMP BA BA OFF OFF ON ON ON RATIO TH STACK IN 0dB ZONE1 ZONE2 CV GEN ATT OFF ON OFF ON ST...

Страница 19: ...MV800 Owner s Manual ...

Страница 20: ...YAMAHA CORPORATION Pro Audio Digital Musical Instrument Division P O Box 3 Hamamatsu 430 8651 Japan V627640 R1 1 CP 20 NP Printed in Taiwan ...

Отзывы: