Periodic maintenance and adjustment
6-30
1
2
3
4
5
6
7
8
9
10
11
12
battery tends to discharge more quickly
if the vehicle is equipped with optional
electrical accessories.
NOTICE
ECA16522
To charge a VRLA (Valve Regulated
Lead Acid) battery, a special (con-
stant-voltage) battery charger is re-
quired. Using a conventional battery
charger will damage the battery.
To store the battery
1. If the vehicle will not be used for
more than one month, remove the
battery, fully charge it, and then
place it in a cool, dry place.
NOTICE:
When removing the
battery, be sure the key is
turned to “OFF”, then discon-
nect the negative lead before
disconnecting the positive
lead.
[ECA16303]
2. If the battery will be stored for more
than two months, check it at least
once a month and fully charge it if
necessary.
3. Fully charge the battery before in-
stallation.
NOTICE:
When install-
ing the battery, be sure the key
is turned to “OFF”, then con-
nect the positive lead before
connecting the negative
lead.
[ECA16841]
4. After installation, make sure that
the battery leads are properly con-
nected to the battery terminals.
NOTICE
ECA16531
Always keep the battery charged.
Storing a discharged battery can
cause permanent battery damage.
EAU73340
Replacing the fuses
Fuse box 1 is located behind the right
side panel.
To access fuse box 1, remove and in-
stall the right side panel and rubber
cover as follows.
1. Remove the nuts and bolt.
2. Pull the right side panel and rubber
cover off as shown.
1. Right side panel
2. Nut
3. Bolt
1
3
2